{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/29631"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/29631","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Thermal performance representation and testing of air solar collectors","abstract":"The present study focusses on the thermal performance representation and testing of air solar collectors with an emphasis on flowrate and leakage effects. The thermal efficiency was evaluated using two methods. In the first method, referred to as the oulet mass flowrate method, the efficiency is based on the product of the outlet mass flowrate, the air specific heat and the temperature rise across the collector. The second method, called the enthalpy balance method, is based on the first law of thermodynamics and takes into account all of the energy fluxes into or out of the collector. Both methods give the user all the information he needs as long as the inlet and outlet mass flowrates are reported. But it has to be recognized that each method of representation gives anomalous results depending on the type of leakage. For example, it is possible, in the outward leakage case, for the enthalpy balance method to give a positive efficiency even though there is no useful energy delivered. In the inward leakage case, the outlet mass flowrate method might give a negative efficiency even though the useful output energy is greater than the input energy. A \"delivered\" efficiency was defined to aid in applying results to real engineering systems and to better represent the energy truly delivered to the load. Experimentally, to take into account the effects of flowrate and leakage rate on the thermal performance of air solar collectors, it is proposed to test air solar collectors at two flowrates and three inlet gage pressures for each of these flowrates. The test facility should include inlet and outlet mass flowrate measurements and a dual-blower system to control the inlet pressure.","abstract_html":"The present study focusses on the thermal performance representation and testing of air solar collectors with an emphasis on flowrate and leakage effects. The thermal efficiency was evaluated using two methods. In the first method, referred to as the oulet mass flowrate method, the efficiency is based on the product of the outlet mass flowrate, the air specific heat and the temperature rise across the collector. The second method, called the enthalpy balance method, is based on the first law of thermodynamics and takes into account all of the energy fluxes into or out of the collector. Both methods give the user all the information he needs as long as the inlet and outlet mass flowrates are reported. But it has to be recognized that each method of representation gives anomalous results depending on the type of leakage. For example, it is possible, in the outward leakage case, for the enthalpy balance method to give a positive efficiency even though there is no useful energy delivered. In the inward leakage case, the outlet mass flowrate method might give a negative efficiency even though the useful output energy is greater than the input energy. A &quot;delivered&quot; efficiency was defined to aid in applying results to real engineering systems and to better represent the energy truly delivered to the load. Experimentally, to take into account the effects of flowrate and leakage rate on the thermal performance of air solar collectors, it is proposed to test air solar collectors at two flowrates and three inlet gage pressures for each of these flowrates. The test facility should include inlet and outlet mass flowrate measurements and a dual-blower system to control the inlet pressure.","abstract_has_math":false,"creators":["Bernier, Michel A."],"institution":"Carleton University","degree_name":"Master of Engineering (M.Eng.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-11-19T07:15:38Z","subjects":["Solar collectors"],"languages":["en"],"rights":["Copyright © 1985 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/1985-12317"],"render_values":[{"text":"10.22215/etd/1985-12317","href":"https://doi.org/10.22215/etd/1985-12317","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/29631","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/29631","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F29631","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bernier, Michel A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T16:58:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T16:58:48Z"]},{"key":"dc:date.issued","label":"Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering (M.Eng.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Solar collectors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 1985 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/1985-12317"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/29631"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The present study focusses on the thermal performance representation and testing of air solar collectors with an emphasis on flowrate and leakage effects. The thermal efficiency was evaluated using two methods. In the first method, referred to as the oulet mass flowrate method, the efficiency is based on the product of the outlet mass flowrate, the air specific heat and the temperature rise across the collector. The second method, called the enthalpy balance method, is based on the first law of thermodynamics and takes into account all of the energy fluxes into or out of the collector. Both methods give the user all the information he needs as long as the inlet and outlet mass flowrates are reported. But it has to be recognized that each method of representation gives anomalous results depending on the type of leakage. For example, it is possible, in the outward leakage case, for the enthalpy balance method to give a positive efficiency even though there is no useful energy delivered. In the inward leakage case, the outlet mass flowrate method might give a negative efficiency even though the useful output energy is greater than the input energy. A \"delivered\" efficiency was defined to aid in applying results to real engineering systems and to better represent the energy truly delivered to the load. Experimentally, to take into account the effects of flowrate and leakage rate on the thermal performance of air solar collectors, it is proposed to test air solar collectors at two flowrates and three inlet gage pressures for each of these flowrates. The test facility should include inlet and outlet mass flowrate measurements and a dual-blower system to control the inlet pressure."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"]},{"key":"dc:title","label":"Title","values":["Thermal performance representation and testing of air solar collectors"]},{"key":"others:access_status","label":"Others Access Status","values":["metadata.only"]}]}],"canonical_facts":{"dc:creator":["Bernier, Michel A."],"dc:date.accessioned":["2025-04-08T16:58:48Z"],"dc:date.available":["2025-04-08T16:58:48Z"],"dc:date.issued":["1985"],"dc:description.abstract":["The present study focusses on the thermal performance representation and testing of air solar collectors with an emphasis on flowrate and leakage effects. The thermal efficiency was evaluated using two methods. In the first method, referred to as the oulet mass flowrate method, the efficiency is based on the product of the outlet mass flowrate, the air specific heat and the temperature rise across the collector. The second method, called the enthalpy balance method, is based on the first law of thermodynamics and takes into account all of the energy fluxes into or out of the collector. Both methods give the user all the information he needs as long as the inlet and outlet mass flowrates are reported. But it has to be recognized that each method of representation gives anomalous results depending on the type of leakage. For example, it is possible, in the outward leakage case, for the enthalpy balance method to give a positive efficiency even though there is no useful energy delivered. In the inward leakage case, the outlet mass flowrate method might give a negative efficiency even though the useful output energy is greater than the input energy. A \"delivered\" efficiency was defined to aid in applying results to real engineering systems and to better represent the energy truly delivered to the load. Experimentally, to take into account the effects of flowrate and leakage rate on the thermal performance of air solar collectors, it is proposed to test air solar collectors at two flowrates and three inlet gage pressures for each of these flowrates. The test facility should include inlet and outlet mass flowrate measurements and a dual-blower system to control the inlet pressure."],"dc:identifier.doi":["10.22215/etd/1985-12317"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/29631"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 1985 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Solar collectors"],"dcterms:accessrights":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"],"dc:title":["Thermal performance representation and testing of air solar collectors"],"dc:type":["thesis"],"others:access_status":["metadata.only"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Engineering (M.Eng.)"]},"updated_at":"2026-11-19T07:15:38Z"}