{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/29723"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/29723","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Liquid electrofluiddynamic high voltage generator","abstract":"An eleotrofluiddynamic high voltage generator has been built using a liquid dielectric fluid. The device, often referred to as a fluid Van de Graaff generator, has a high internal impedance and produces a maximum voltage of between 50 and 60 KV at a current of 1.5x10-6 amps.The effect on the device output of varying several of the system parameters was examined, and it was found that varying the ionizer supply voltage was the best method for controlling the output current. Two factors, in particular, limited the output of the device, the fluid flow rate and the ionizer design. The problems of fluid contamination and fluid leakage caused the greatest experimental difficulties.","abstract_html":"An eleotrofluiddynamic high voltage generator has been built using a liquid dielectric fluid. The device, often referred to as a fluid Van de Graaff generator, has a high internal impedance and produces a maximum voltage of between 50 and 60 KV at a current of 1.5x10-6 amps.The effect on the device output of varying several of the system parameters was examined, and it was found that varying the ionizer supply voltage was the best method for controlling the output current. Two factors, in particular, limited the output of the device, the fluid flow rate and the ionizer design. The problems of fluid contamination and fluid leakage caused the greatest experimental difficulties.","abstract_has_math":false,"creators":["Cope, Douglas Leon"],"institution":"Carleton University","degree_name":"Master of Engineering (M.Eng.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1970,"date_issued":"1970","date_published":"1970","updated_at":"2026-11-19T06:55:15Z","subjects":["Van De Graaf Generator"],"languages":["en"],"rights":["Copyright © 1970 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/29723"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/29723","href":"https://hdl.handle.net/20.500.14718/29723","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/1970-12489","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/1970-12489","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F29723","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F29723","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Cope, Douglas Leon"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T16:59:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T16:59:33Z"]},{"key":"dc:date.issued","label":"Date","values":["1970"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering (M.Eng.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Van De Graaf Generator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 1970 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/1970-12489"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/29723"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An eleotrofluiddynamic high voltage generator has been built using a liquid dielectric fluid. The device, often referred to as a fluid Van de Graaff generator, has a high internal impedance and produces a maximum voltage of between 50 and 60 KV at a current of 1.5x10-6 amps.The effect on the device output of varying several of the system parameters was examined, and it was found that varying the ionizer supply voltage was the best method for controlling the output current. Two factors, in particular, limited the output of the device, the fluid flow rate and the ionizer design. The problems of fluid contamination and fluid leakage caused the greatest experimental difficulties."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"]},{"key":"dc:title","label":"Title","values":["Liquid electrofluiddynamic high voltage generator"]},{"key":"others:access_status","label":"Others Access Status","values":["metadata.only"]}]}],"canonical_facts":{"dc:creator":["Cope, Douglas Leon"],"dc:date.accessioned":["2025-04-08T16:59:33Z"],"dc:date.available":["2025-04-08T16:59:33Z"],"dc:date.issued":["1970"],"dc:description.abstract":["An eleotrofluiddynamic high voltage generator has been built using a liquid dielectric fluid. The device, often referred to as a fluid Van de Graaff generator, has a high internal impedance and produces a maximum voltage of between 50 and 60 KV at a current of 1.5x10-6 amps.The effect on the device output of varying several of the system parameters was examined, and it was found that varying the ionizer supply voltage was the best method for controlling the output current. Two factors, in particular, limited the output of the device, the fluid flow rate and the ionizer design. The problems of fluid contamination and fluid leakage caused the greatest experimental difficulties."],"dc:identifier.doi":["10.22215/etd/1970-12489"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/29723"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 1970 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Van De Graaf Generator"],"dcterms:accessrights":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"],"dc:title":["Liquid electrofluiddynamic high voltage generator"],"dc:type":["thesis"],"others:access_status":["metadata.only"],"thesis:degree_discipline":["Engineering, Electrical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Engineering (M.Eng.)"]},"updated_at":"2026-11-19T06:55:15Z"}