{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/32175"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/32175","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Non-invasive Assessment and Compensation of Soft-tissue Artefacts in Hip Joint Kinematics","abstract":"Determination of the hip joint centre by functional methods suffers inaccuracy due to the soft tissue artefact; this is the relative motion between the markers and the underlying bone due to the muscle and skin deformation. To solve this issue, we present a non-invasive method to assess and reduce the effect of the soft tissue artefact using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction of the hip joint. The marker displacements are dependent on the movement type, being relatively larger in abduction movement. The quantification of soft tissue artefacts is used as a basis for a correction procedure for hip joint centre and minimizing the soft tissue artefact effects. Results show that our method for soft tissue artefact assessment and minimization reduces the error in the functional hip joint centre approximately from 13-23mm to 7-14 mm.","abstract_html":"Determination of the hip joint centre by functional methods suffers inaccuracy due to the soft tissue artefact; this is the relative motion between the markers and the underlying bone due to the muscle and skin deformation. To solve this issue, we present a non-invasive method to assess and reduce the effect of the soft tissue artefact using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction of the hip joint. The marker displacements are dependent on the movement type, being relatively larger in abduction movement. The quantification of soft tissue artefacts is used as a basis for a correction procedure for hip joint centre and minimizing the soft tissue artefact effects. Results show that our method for soft tissue artefact assessment and minimization reduces the error in the functional hip joint centre approximately from 13-23mm to 7-14 mm.","abstract_has_math":false,"creators":["Rouhandeh, Azadeh"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T06:55:34Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10578"],"render_values":[{"text":"10.22215/etd/2014-10578","href":"https://doi.org/10.22215/etd/2014-10578","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/32175","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/32175","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F32175","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rouhandeh, Azadeh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T17:38:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T17:38:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10578"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/32175"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Determination of the hip joint centre by functional methods suffers inaccuracy due to the soft tissue artefact; this is the relative motion between the markers and the underlying bone due to the muscle and skin deformation. To solve this issue, we present a non-invasive method to assess and reduce the effect of the soft tissue artefact using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction of the hip joint. The marker displacements are dependent on the movement type, being relatively larger in abduction movement. The quantification of soft tissue artefacts is used as a basis for a correction procedure for hip joint centre and minimizing the soft tissue artefact effects. Results show that our method for soft tissue artefact assessment and minimization reduces the error in the functional hip joint centre approximately from 13-23mm to 7-14 mm."]},{"key":"dc:title","label":"Title","values":["Non-invasive Assessment and Compensation of Soft-tissue Artefacts in Hip Joint Kinematics"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Rouhandeh, Azadeh"],"dc:date.accessioned":["2025-04-08T17:38:51Z"],"dc:date.available":["2025-04-08T17:38:51Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Determination of the hip joint centre by functional methods suffers inaccuracy due to the soft tissue artefact; this is the relative motion between the markers and the underlying bone due to the muscle and skin deformation. To solve this issue, we present a non-invasive method to assess and reduce the effect of the soft tissue artefact using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction of the hip joint. The marker displacements are dependent on the movement type, being relatively larger in abduction movement. The quantification of soft tissue artefacts is used as a basis for a correction procedure for hip joint centre and minimizing the soft tissue artefact effects. Results show that our method for soft tissue artefact assessment and minimization reduces the error in the functional hip joint centre approximately from 13-23mm to 7-14 mm."],"dc:identifier.doi":["10.22215/etd/2014-10578"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/32175"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Non-invasive Assessment and Compensation of Soft-tissue Artefacts in Hip Joint Kinematics"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:55:34Z"}