{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/32375"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/32375","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Numerical Modelling of the No-Core-Melt Passive Safety Feature in the Generation IV Canadian SCWR","abstract":"Heat transfer through a typical fuel channel in a Generation IV Canadian Supercritical Water Reactor was modelled numerically using Finite Element Method software. With the objective of limiting the fuel cladding to sub-melting temperatures during a Loss of Coolant Accident, it was found that two distinct fuel channel designs both attained maximum cladding surface temperatures of T = 1,120 C; a result that compared favourably with the 1,450 C melting point of the stainless steel cladding. However, given the similar temperatures yielded by the reference and alternate fuel channel designs, it was deemed necessary to devise another metric for identifying the better performing variant. In this vein, the ratios of LOCA to normal operation thermal fluxes were computed and it was observed that the reference configuration performed best by limiting losses in normal operation while also permitting sufficient heat rejection to the moderator during the LOCA.","abstract_html":"Heat transfer through a typical fuel channel in a Generation IV Canadian Supercritical Water Reactor was modelled numerically using Finite Element Method software. With the objective of limiting the fuel cladding to sub-melting temperatures during a Loss of Coolant Accident, it was found that two distinct fuel channel designs both attained maximum cladding surface temperatures of T = 1,120 C; a result that compared favourably with the 1,450 C melting point of the stainless steel cladding. However, given the similar temperatures yielded by the reference and alternate fuel channel designs, it was deemed necessary to devise another metric for identifying the better performing variant. In this vein, the ratios of LOCA to normal operation thermal fluxes were computed and it was observed that the reference configuration performed best by limiting losses in normal operation while also permitting sufficient heat rejection to the moderator during the LOCA.","abstract_has_math":false,"creators":["Schmidt, Graeme"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Aerospace","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:05:31Z","subjects":["Aerospace engineering"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10489"],"render_values":[{"text":"10.22215/etd/2014-10489","href":"https://doi.org/10.22215/etd/2014-10489","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/32375","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/32375","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F32375","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Schmidt, Graeme"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T17:42:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T17:42:35Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Aerospace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aerospace engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10489"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/32375"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Heat transfer through a typical fuel channel in a Generation IV Canadian Supercritical Water Reactor was modelled numerically using Finite Element Method software. With the objective of limiting the fuel cladding to sub-melting temperatures during a Loss of Coolant Accident, it was found that two distinct fuel channel designs both attained maximum cladding surface temperatures of T = 1,120 C; a result that compared favourably with the 1,450 C melting point of the stainless steel cladding. However, given the similar temperatures yielded by the reference and alternate fuel channel designs, it was deemed necessary to devise another metric for identifying the better performing variant. In this vein, the ratios of LOCA to normal operation thermal fluxes were computed and it was observed that the reference configuration performed best by limiting losses in normal operation while also permitting sufficient heat rejection to the moderator during the LOCA."]},{"key":"dc:title","label":"Title","values":["Numerical Modelling of the No-Core-Melt Passive Safety Feature in the Generation IV Canadian SCWR"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Schmidt, Graeme"],"dc:date.accessioned":["2025-04-08T17:42:35Z"],"dc:date.available":["2025-04-08T17:42:35Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Heat transfer through a typical fuel channel in a Generation IV Canadian Supercritical Water Reactor was modelled numerically using Finite Element Method software. With the objective of limiting the fuel cladding to sub-melting temperatures during a Loss of Coolant Accident, it was found that two distinct fuel channel designs both attained maximum cladding surface temperatures of T = 1,120 C; a result that compared favourably with the 1,450 C melting point of the stainless steel cladding. However, given the similar temperatures yielded by the reference and alternate fuel channel designs, it was deemed necessary to devise another metric for identifying the better performing variant. In this vein, the ratios of LOCA to normal operation thermal fluxes were computed and it was observed that the reference configuration performed best by limiting losses in normal operation while also permitting sufficient heat rejection to the moderator during the LOCA."],"dc:identifier.doi":["10.22215/etd/2014-10489"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/32375"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Aerospace engineering"],"dc:title":["Numerical Modelling of the No-Core-Melt Passive Safety Feature in the Generation IV Canadian SCWR"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Aerospace"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:05:31Z"}