{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/32414"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/32414","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Sensitivity and Distortion Studies of Positron Emission Trancking System (PeTrack)","abstract":"Positron Emission Tracking (PeTrack) is a new real-time 3D tracking technique. The project studied the sensitivity and distortion of the PeTrack system with four different detector field of view (FOV) configurations using Monte-Carlo simulation software (GATE). The simulation studies demonstrated the clear boundaries for FOV and also revealed a local distortion up to 1 mm for PeTrack. The simulation also showed that the detector misalignment could introduce the distortion to the system. The results of simulations lead us to calibrate the PeTrack system to obtain the global scaling factors. However, since PeTrack has a non-uniform distortion across FOV, the global scaling factors were helpful to only some extent. The value of calculated average error after global scaling correction is less than 1 mm. The PeTrack system is also co-registered with an x-ray imaging C-arm to evaluate the tracking performance.","abstract_html":"Positron Emission Tracking (PeTrack) is a new real-time 3D tracking technique. The project studied the sensitivity and distortion of the PeTrack system with four different detector field of view (FOV) configurations using Monte-Carlo simulation software (GATE). The simulation studies demonstrated the clear boundaries for FOV and also revealed a local distortion up to 1 mm for PeTrack. The simulation also showed that the detector misalignment could introduce the distortion to the system. The results of simulations lead us to calibrate the PeTrack system to obtain the global scaling factors. However, since PeTrack has a non-uniform distortion across FOV, the global scaling factors were helpful to only some extent. The value of calculated average error after global scaling correction is less than 1 mm. The PeTrack system is also co-registered with an x-ray imaging C-arm to evaluate the tracking performance.","abstract_has_math":false,"creators":["Razavi, Simin"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:14:08Z","subjects":["Medical physics"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10460"],"render_values":[{"text":"10.22215/etd/2014-10460","href":"https://doi.org/10.22215/etd/2014-10460","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/32414","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/32414","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F32414","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Razavi, Simin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T17:43:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T17:43:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Medical physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10460"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/32414"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Positron Emission Tracking (PeTrack) is a new real-time 3D tracking technique. The project studied the sensitivity and distortion of the PeTrack system with four different detector field of view (FOV) configurations using Monte-Carlo simulation software (GATE). The simulation studies demonstrated the clear boundaries for FOV and also revealed a local distortion up to 1 mm for PeTrack. The simulation also showed that the detector misalignment could introduce the distortion to the system. The results of simulations lead us to calibrate the PeTrack system to obtain the global scaling factors. However, since PeTrack has a non-uniform distortion across FOV, the global scaling factors were helpful to only some extent. The value of calculated average error after global scaling correction is less than 1 mm. The PeTrack system is also co-registered with an x-ray imaging C-arm to evaluate the tracking performance."]},{"key":"dc:title","label":"Title","values":["Sensitivity and Distortion Studies of Positron Emission Trancking System (PeTrack)"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Razavi, Simin"],"dc:date.accessioned":["2025-04-08T17:43:16Z"],"dc:date.available":["2025-04-08T17:43:16Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Positron Emission Tracking (PeTrack) is a new real-time 3D tracking technique. The project studied the sensitivity and distortion of the PeTrack system with four different detector field of view (FOV) configurations using Monte-Carlo simulation software (GATE). The simulation studies demonstrated the clear boundaries for FOV and also revealed a local distortion up to 1 mm for PeTrack. The simulation also showed that the detector misalignment could introduce the distortion to the system. The results of simulations lead us to calibrate the PeTrack system to obtain the global scaling factors. However, since PeTrack has a non-uniform distortion across FOV, the global scaling factors were helpful to only some extent. The value of calculated average error after global scaling correction is less than 1 mm. The PeTrack system is also co-registered with an x-ray imaging C-arm to evaluate the tracking performance."],"dc:identifier.doi":["10.22215/etd/2014-10460"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/32414"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Medical physics"],"dc:title":["Sensitivity and Distortion Studies of Positron Emission Trancking System (PeTrack)"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:14:08Z"}