{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/32535"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/32535","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Motion Estimation and Registration of B-Mode Ultrasound Images for Improved Visualisation","abstract":"This thesis presents a method for motion tracking between ultrasound images that originated from moving an ultrasound probe. The motion tracking is done in two steps: In the first step, a modified block-matching search is used to track the motion between frames by tracking the speckle and the tissues in the images. From the modified block-matching approach, the global motion vector can be seen. In the second step, areas with motion vectors in the direction of the probes’ motion are put through another motion tracking algorithm called phase correlation. Doing so will improve the overall motion estimation. Phase correlation provides a smoother vector field compared to block-matching. At the end, an extended field-of-view frame will be obtained.","abstract_html":"This thesis presents a method for motion tracking between ultrasound images that originated from moving an ultrasound probe. The motion tracking is done in two steps: In the first step, a modified block-matching search is used to track the motion between frames by tracking the speckle and the tissues in the images. From the modified block-matching approach, the global motion vector can be seen. In the second step, areas with motion vectors in the direction of the probes’ motion are put through another motion tracking algorithm called phase correlation. Doing so will improve the overall motion estimation. Phase correlation provides a smoother vector field compared to block-matching. At the end, an extended field-of-view frame will be obtained.","abstract_has_math":false,"creators":["Awwad, Yazan"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:06:21Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/32535"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/32535","href":"https://hdl.handle.net/20.500.14718/32535","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2014-10351","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2014-10351","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F32535","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Awwad, Yazan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T17:45:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T17:45:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10351"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/32535"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents a method for motion tracking between ultrasound images that originated from moving an ultrasound probe. The motion tracking is done in two steps: In the first step, a modified block-matching search is used to track the motion between frames by tracking the speckle and the tissues in the images. From the modified block-matching approach, the global motion vector can be seen. In the second step, areas with motion vectors in the direction of the probes’ motion are put through another motion tracking algorithm called phase correlation. Doing so will improve the overall motion estimation. Phase correlation provides a smoother vector field compared to block-matching. At the end, an extended field-of-view frame will be obtained."]},{"key":"dc:title","label":"Title","values":["Motion Estimation and Registration of B-Mode Ultrasound Images for Improved Visualisation"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Awwad, Yazan"],"dc:date.accessioned":["2025-04-08T17:45:16Z"],"dc:date.available":["2025-04-08T17:45:16Z"],"dc:date.issued":["2014"],"dc:description.abstract":["This thesis presents a method for motion tracking between ultrasound images that originated from moving an ultrasound probe. The motion tracking is done in two steps: In the first step, a modified block-matching search is used to track the motion between frames by tracking the speckle and the tissues in the images. From the modified block-matching approach, the global motion vector can be seen. In the second step, areas with motion vectors in the direction of the probes’ motion are put through another motion tracking algorithm called phase correlation. Doing so will improve the overall motion estimation. Phase correlation provides a smoother vector field compared to block-matching. At the end, an extended field-of-view frame will be obtained."],"dc:identifier.doi":["10.22215/etd/2014-10351"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/32535"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Motion Estimation and Registration of B-Mode Ultrasound Images for Improved Visualisation"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:06:21Z"}