{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/36236"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/36236","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Low-dose radiography by flying x-ray spot scanning (Lisar).","abstract":"Low-dose radiography can be achieved with flying x-ray spot scanning. An apparatus named 'LISAR', for Low-Intensity Scanning Apparatus for Radiography, was designed and built for the purpose of producing low-dose radiographs. The x-ray photon detection system uses a sodium iodide (thallium activated) crystal coupled to a photomultiplier tube resulting in an x-ray photon detection efficiency near 100%. Radiographs have been produced where the radiation dose given to the subject was as low as 6 urad. This thesis describes the theory and application of flying-spot scanning to low-dose radiography and the design of the LISAR.","abstract_html":"Low-dose radiography can be achieved with flying x-ray spot scanning. An apparatus named &#x27;LISAR&#x27;, for Low-Intensity Scanning Apparatus for Radiography, was designed and built for the purpose of producing low-dose radiographs. The x-ray photon detection system uses a sodium iodide (thallium activated) crystal coupled to a photomultiplier tube resulting in an x-ray photon detection efficiency near 100%. Radiographs have been produced where the radiation dose given to the subject was as low as 6 urad. This thesis describes the theory and application of flying-spot scanning to low-dose radiography and the design of the LISAR.","abstract_has_math":false,"creators":["Baleshta, Theodore M."],"institution":"Carleton University","degree_name":"Master of Arts (M.Eng.)","degree_level":"Master's","degree_discipline":"Engineering, Materials","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1969,"date_issued":"1969","date_published":"1969","updated_at":"2026-11-19T06:59:10Z","subjects":["Radiography","Radiation -- Dosage"],"languages":["en"],"rights":["Copyright © 1969 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/1969-12303"],"render_values":[{"text":"10.22215/etd/1969-12303","href":"https://doi.org/10.22215/etd/1969-12303","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/36236","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/36236","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F36236","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Baleshta, Theodore M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T18:46:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T18:46:04Z"]},{"key":"dc:date.issued","label":"Date","values":["1969"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Materials"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Arts (M.Eng.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Radiography","Radiation -- Dosage"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 1969 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/1969-12303"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/36236"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Low-dose radiography can be achieved with flying x-ray spot scanning. An apparatus named 'LISAR', for Low-Intensity Scanning Apparatus for Radiography, was designed and built for the purpose of producing low-dose radiographs. The x-ray photon detection system uses a sodium iodide (thallium activated) crystal coupled to a photomultiplier tube resulting in an x-ray photon detection efficiency near 100%. Radiographs have been produced where the radiation dose given to the subject was as low as 6 urad. This thesis describes the theory and application of flying-spot scanning to low-dose radiography and the design of the LISAR."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"]},{"key":"dc:title","label":"Title","values":["Low-dose radiography by flying x-ray spot scanning (Lisar)."]},{"key":"others:access_status","label":"Others Access Status","values":["metadata.only"]}]}],"canonical_facts":{"dc:creator":["Baleshta, Theodore M."],"dc:date.accessioned":["2025-04-08T18:46:04Z"],"dc:date.available":["2025-04-08T18:46:04Z"],"dc:date.issued":["1969"],"dc:description.abstract":["Low-dose radiography can be achieved with flying x-ray spot scanning. An apparatus named 'LISAR', for Low-Intensity Scanning Apparatus for Radiography, was designed and built for the purpose of producing low-dose radiographs. The x-ray photon detection system uses a sodium iodide (thallium activated) crystal coupled to a photomultiplier tube resulting in an x-ray photon detection efficiency near 100%. Radiographs have been produced where the radiation dose given to the subject was as low as 6 urad. This thesis describes the theory and application of flying-spot scanning to low-dose radiography and the design of the LISAR."],"dc:identifier.doi":["10.22215/etd/1969-12303"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/36236"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 1969 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Radiography","Radiation -- Dosage"],"dcterms:accessrights":["This work is available on request. You can request a copy at https://library.carleton.ca/forms/request-pdf-copy-thesis"],"dc:title":["Low-dose radiography by flying x-ray spot scanning (Lisar)."],"dc:type":["thesis"],"others:access_status":["metadata.only"],"thesis:degree_discipline":["Engineering, Materials"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Arts (M.Eng.)"]},"updated_at":"2026-11-19T06:59:10Z"}