{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/37022"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/37022","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Aspects of nonlinear dielectric spectroscopy in the noninvasive determination of glucose","abstract":"Diabetes is a chronic disease of the metabolic system with serious health and social implications. Research in noninvasive methods to measure blood glucose levels is ongoing as a means to improve the monitoring techniques necessary for the management of this disease.In this dissertation the technique of nonlinear dielectric spectroscopy (NLDS) is evaluated as a noninvasive method in measuring glucose levels. NLDS injects a low frequency probing current into a sample, and obtains meaningful information through the analysis of system nonlinearity. A suspension of the yeast S. cerevisiae is used in the experimental NLDS work, and metabolically active and quiescent yeast states are considered, as well as the electrolyte medium. Experimental time-course spectral data are presented. Electrode polarization artifacts are examined as masking the biological signal of interest. An empirical model is fitted to the experimental data at discrete points over time as a method to compensate for artifacts.","abstract_html":"Diabetes is a chronic disease of the metabolic system with serious health and social implications. Research in noninvasive methods to measure blood glucose levels is ongoing as a means to improve the monitoring techniques necessary for the management of this disease.In this dissertation the technique of nonlinear dielectric spectroscopy (NLDS) is evaluated as a noninvasive method in measuring glucose levels. NLDS injects a low frequency probing current into a sample, and obtains meaningful information through the analysis of system nonlinearity. A suspension of the yeast S. cerevisiae is used in the experimental NLDS work, and metabolically active and quiescent yeast states are considered, as well as the electrolyte medium. Experimental time-course spectral data are presented. Electrode polarization artifacts are examined as masking the biological signal of interest. An empirical model is fitted to the experimental data at discrete points over time as a method to compensate for artifacts.","abstract_has_math":false,"creators":["McLellan, Christopher Jarl"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Systems and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-19T07:07:11Z","subjects":["Blood sugar -- Analysis","Glucose -- Measurement","Spectrum analysis","Nonlinear optics","Impedance spectroscopy","Blood sugar monitoring","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2007 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2007-07648"],"render_values":[{"text":"10.22215/etd/2007-07648","href":"https://doi.org/10.22215/etd/2007-07648","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/37022","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/37022","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F37022","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["McLellan, Christopher Jarl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T18:58:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T18:58:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Systems and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Blood sugar -- Analysis","Glucose -- Measurement","Spectrum analysis","Nonlinear optics","Impedance spectroscopy","Blood sugar monitoring","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2007 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2007-07648"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/37022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Diabetes is a chronic disease of the metabolic system with serious health and social implications. Research in noninvasive methods to measure blood glucose levels is ongoing as a means to improve the monitoring techniques necessary for the management of this disease.In this dissertation the technique of nonlinear dielectric spectroscopy (NLDS) is evaluated as a noninvasive method in measuring glucose levels. NLDS injects a low frequency probing current into a sample, and obtains meaningful information through the analysis of system nonlinearity. A suspension of the yeast S. cerevisiae is used in the experimental NLDS work, and metabolically active and quiescent yeast states are considered, as well as the electrolyte medium. Experimental time-course spectral data are presented. Electrode polarization artifacts are examined as masking the biological signal of interest. An empirical model is fitted to the experimental data at discrete points over time as a method to compensate for artifacts."]},{"key":"dc:title","label":"Title","values":["Aspects of nonlinear dielectric spectroscopy in the noninvasive determination of glucose"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["McLellan, Christopher Jarl"],"dc:date.accessioned":["2025-04-08T18:58:48Z"],"dc:date.available":["2025-04-08T18:58:48Z"],"dc:date.issued":["2007"],"dc:description.abstract":["Diabetes is a chronic disease of the metabolic system with serious health and social implications. Research in noninvasive methods to measure blood glucose levels is ongoing as a means to improve the monitoring techniques necessary for the management of this disease.In this dissertation the technique of nonlinear dielectric spectroscopy (NLDS) is evaluated as a noninvasive method in measuring glucose levels. NLDS injects a low frequency probing current into a sample, and obtains meaningful information through the analysis of system nonlinearity. A suspension of the yeast S. cerevisiae is used in the experimental NLDS work, and metabolically active and quiescent yeast states are considered, as well as the electrolyte medium. Experimental time-course spectral data are presented. Electrode polarization artifacts are examined as masking the biological signal of interest. An empirical model is fitted to the experimental data at discrete points over time as a method to compensate for artifacts."],"dc:identifier.doi":["10.22215/etd/2007-07648"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/37022"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2007 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Blood sugar -- Analysis","Glucose -- Measurement","Spectrum analysis","Nonlinear optics","Impedance spectroscopy","Blood sugar monitoring","Biomedical engineering"],"dc:title":["Aspects of nonlinear dielectric spectroscopy in the noninvasive determination of glucose"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Systems and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:07:11Z"}