{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38121"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38121","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Identification of Thermal Abnormalities by Analysis of Abdominal Infrared Thermal Images of Neonatal Patients","abstract":"Necrotizing enterocolitis (NEC), is a devastating inflammatory disease of infants for which there is no cure and exact causes remain unknown. Diagnoses are limited to radiographic findings and in most institutions Modified Bell’s Criteria is used, neither are capable of reliable early detection. In this thesis, a novel method of abdominal infrared thermal imaging is proposed that allows direct measurements of skin temperature, which are capable of unveiling thermal abnormalities that may indicate intestinal inflammation characteristic of NEC. Abdominal thermal symmetry analysis was performed, results obtained from the 20 normal and the 9 NEC affected infants were statistically compared. A higher degree of thermal asymmetry was seen with the NEC group in comparison to the Normal group, notably when image enhancement techniques were done. We are hopeful that this new non-contact, non-ionizing method may potentially offer an early diagnostic tool.","abstract_html":"Necrotizing enterocolitis (NEC), is a devastating inflammatory disease of infants for which there is no cure and exact causes remain unknown. Diagnoses are limited to radiographic findings and in most institutions Modified Bell’s Criteria is used, neither are capable of reliable early detection. In this thesis, a novel method of abdominal infrared thermal imaging is proposed that allows direct measurements of skin temperature, which are capable of unveiling thermal abnormalities that may indicate intestinal inflammation characteristic of NEC. Abdominal thermal symmetry analysis was performed, results obtained from the 20 normal and the 9 NEC affected infants were statistically compared. A higher degree of thermal asymmetry was seen with the NEC group in comparison to the Normal group, notably when image enhancement techniques were done. We are hopeful that this new non-contact, non-ionizing method may potentially offer an early diagnostic tool.","abstract_has_math":false,"creators":["Nur, Ruqia"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:13:13Z","subjects":["PHYSICAL SCIENCES Engineering - Biomedical"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10076"],"render_values":[{"text":"10.22215/etd/2014-10076","href":"https://doi.org/10.22215/etd/2014-10076","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/38121","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/38121","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38121","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nur, Ruqia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:16:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:16:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["PHYSICAL SCIENCES Engineering - Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10076"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38121"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Necrotizing enterocolitis (NEC), is a devastating inflammatory disease of infants for which there is no cure and exact causes remain unknown. Diagnoses are limited to radiographic findings and in most institutions Modified Bell’s Criteria is used, neither are capable of reliable early detection. In this thesis, a novel method of abdominal infrared thermal imaging is proposed that allows direct measurements of skin temperature, which are capable of unveiling thermal abnormalities that may indicate intestinal inflammation characteristic of NEC. Abdominal thermal symmetry analysis was performed, results obtained from the 20 normal and the 9 NEC affected infants were statistically compared. A higher degree of thermal asymmetry was seen with the NEC group in comparison to the Normal group, notably when image enhancement techniques were done. We are hopeful that this new non-contact, non-ionizing method may potentially offer an early diagnostic tool."]},{"key":"dc:title","label":"Title","values":["Identification of Thermal Abnormalities by Analysis of Abdominal Infrared Thermal Images of Neonatal Patients"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Nur, Ruqia"],"dc:date.accessioned":["2025-04-08T19:16:38Z"],"dc:date.available":["2025-04-08T19:16:38Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Necrotizing enterocolitis (NEC), is a devastating inflammatory disease of infants for which there is no cure and exact causes remain unknown. Diagnoses are limited to radiographic findings and in most institutions Modified Bell’s Criteria is used, neither are capable of reliable early detection. In this thesis, a novel method of abdominal infrared thermal imaging is proposed that allows direct measurements of skin temperature, which are capable of unveiling thermal abnormalities that may indicate intestinal inflammation characteristic of NEC. Abdominal thermal symmetry analysis was performed, results obtained from the 20 normal and the 9 NEC affected infants were statistically compared. A higher degree of thermal asymmetry was seen with the NEC group in comparison to the Normal group, notably when image enhancement techniques were done. We are hopeful that this new non-contact, non-ionizing method may potentially offer an early diagnostic tool."],"dc:identifier.doi":["10.22215/etd/2014-10076"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38121"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["PHYSICAL SCIENCES Engineering - Biomedical"],"dc:title":["Identification of Thermal Abnormalities by Analysis of Abdominal Infrared Thermal Images of Neonatal Patients"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:13:13Z"}