{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38131"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38131","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Prototype Testing of a Modified Poroelastic Matric Suction Sensor.","abstract":"The matric suction is one of the stress state variables used in the interpretation of the engineering behaviour of soils. This thesis documents development of a Poroelastic Matric Suction Sensor (PE sensor). The advantage of this sensor is that it is a direct method with a relatively large range of suction measurement (up to 8MPa), without any cavitation. Modifications of the sensor were carried out to increase accuracy. The modified sensor was then evaluated by comparison with total suction measurements made in artificial silt and in fine grained material. In addition, the behaviour of the sensor when using oil sand tailings was also monitored and compared. The experimental results showed that the suction range of the sensor is about 8MPa, with a mean relative uncertainty of 0.5MPa, a standard deviation of 0.5MPa compared to the WP4T PotentiaMeter Device. The behaviour of the sensor at temperatures below 00C was also investigated.","abstract_html":"The matric suction is one of the stress state variables used in the interpretation of the engineering behaviour of soils. This thesis documents development of a Poroelastic Matric Suction Sensor (PE sensor). The advantage of this sensor is that it is a direct method with a relatively large range of suction measurement (up to 8MPa), without any cavitation. Modifications of the sensor were carried out to increase accuracy. The modified sensor was then evaluated by comparison with total suction measurements made in artificial silt and in fine grained material. In addition, the behaviour of the sensor when using oil sand tailings was also monitored and compared. The experimental results showed that the suction range of the sensor is about 8MPa, with a mean relative uncertainty of 0.5MPa, a standard deviation of 0.5MPa compared to the WP4T PotentiaMeter Device. The behaviour of the sensor at temperatures below 00C was also investigated.","abstract_has_math":false,"creators":["Jayasinghe, Prabodha"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T06:51:54Z","subjects":["PHYSICAL SCIENCES Geotechnology","PHYSICAL SCIENCES Engineering - Environmental","PHYSICAL SCIENCES Engineering - General"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38131"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/38131","href":"https://hdl.handle.net/20.500.14718/38131","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2014-10071","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2014-10071","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38131","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Jayasinghe, Prabodha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:17:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:17:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["PHYSICAL SCIENCES Geotechnology","PHYSICAL SCIENCES Engineering - Environmental","PHYSICAL SCIENCES Engineering - General"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10071"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38131"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The matric suction is one of the stress state variables used in the interpretation of the engineering behaviour of soils. This thesis documents development of a Poroelastic Matric Suction Sensor (PE sensor). The advantage of this sensor is that it is a direct method with a relatively large range of suction measurement (up to 8MPa), without any cavitation. Modifications of the sensor were carried out to increase accuracy. The modified sensor was then evaluated by comparison with total suction measurements made in artificial silt and in fine grained material. In addition, the behaviour of the sensor when using oil sand tailings was also monitored and compared. The experimental results showed that the suction range of the sensor is about 8MPa, with a mean relative uncertainty of 0.5MPa, a standard deviation of 0.5MPa compared to the WP4T PotentiaMeter Device. The behaviour of the sensor at temperatures below 00C was also investigated."]},{"key":"dc:title","label":"Title","values":["Prototype Testing of a Modified Poroelastic Matric Suction Sensor."]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Jayasinghe, Prabodha"],"dc:date.accessioned":["2025-04-08T19:17:22Z"],"dc:date.available":["2025-04-08T19:17:22Z"],"dc:date.issued":["2014"],"dc:description.abstract":["The matric suction is one of the stress state variables used in the interpretation of the engineering behaviour of soils. This thesis documents development of a Poroelastic Matric Suction Sensor (PE sensor). The advantage of this sensor is that it is a direct method with a relatively large range of suction measurement (up to 8MPa), without any cavitation. Modifications of the sensor were carried out to increase accuracy. The modified sensor was then evaluated by comparison with total suction measurements made in artificial silt and in fine grained material. In addition, the behaviour of the sensor when using oil sand tailings was also monitored and compared. The experimental results showed that the suction range of the sensor is about 8MPa, with a mean relative uncertainty of 0.5MPa, a standard deviation of 0.5MPa compared to the WP4T PotentiaMeter Device. The behaviour of the sensor at temperatures below 00C was also investigated."],"dc:identifier.doi":["10.22215/etd/2014-10071"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38131"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["PHYSICAL SCIENCES Geotechnology","PHYSICAL SCIENCES Engineering - Environmental","PHYSICAL SCIENCES Engineering - General"],"dc:title":["Prototype Testing of a Modified Poroelastic Matric Suction Sensor."],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:51:54Z"}