{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38147"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38147","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Deformation and Stresses Generated on The Bolted Flange Joint Assembly and The Grayloc Clamp Connector at Elevated Temperatures","abstract":"Finite element analyses were performed to investigate the leakage and structural integrity of the bolted flange joint assembly (BFJA) and Grayloc clamp connector (GCC), when each assembly was subjected to bolt preload, internal pressure and thermal loadings. The thermal loadings were divided into spatially-uniform and spatially-nonuniform temperatures. The internal pressure for both assemblies was 27 MPa. The BFJA was found to have satisfactory leakage and structural performance for the thermal loadings expected on the low-temperature (260 °C) side of the Carleton Supercritical Water (CSCW) loop. The GCC was found to have satisfactory leakage and structural performance for the thermal loadings expected on the high-temperature (600 °C) side of the CSCW loop. The leakage integrity of the GCC was found to fail for temperature gradients as high as 100 °C. The use of the GCC on the exit of the test section employed on the CSCW loop was not recommended.","abstract_html":"Finite element analyses were performed to investigate the leakage and structural integrity of the bolted flange joint assembly (BFJA) and Grayloc clamp connector (GCC), when each assembly was subjected to bolt preload, internal pressure and thermal loadings. The thermal loadings were divided into spatially-uniform and spatially-nonuniform temperatures. The internal pressure for both assemblies was 27 MPa. The BFJA was found to have satisfactory leakage and structural performance for the thermal loadings expected on the low-temperature (260 °C) side of the Carleton Supercritical Water (CSCW) loop. The GCC was found to have satisfactory leakage and structural performance for the thermal loadings expected on the high-temperature (600 °C) side of the CSCW loop. The leakage integrity of the GCC was found to fail for temperature gradients as high as 100 °C. The use of the GCC on the exit of the test section employed on the CSCW loop was not recommended.","abstract_has_math":false,"creators":["Mogri, Mustafa"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:14:33Z","subjects":["PHYSICAL SCIENCES Engineering - Mechanical"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10104"],"render_values":[{"text":"10.22215/etd/2014-10104","href":"https://doi.org/10.22215/etd/2014-10104","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/38147","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/38147","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38147","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mogri, Mustafa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:17:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:17:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["PHYSICAL SCIENCES Engineering - Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10104"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38147"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Finite element analyses were performed to investigate the leakage and structural integrity of the bolted flange joint assembly (BFJA) and Grayloc clamp connector (GCC), when each assembly was subjected to bolt preload, internal pressure and thermal loadings. The thermal loadings were divided into spatially-uniform and spatially-nonuniform temperatures. The internal pressure for both assemblies was 27 MPa. The BFJA was found to have satisfactory leakage and structural performance for the thermal loadings expected on the low-temperature (260 °C) side of the Carleton Supercritical Water (CSCW) loop. The GCC was found to have satisfactory leakage and structural performance for the thermal loadings expected on the high-temperature (600 °C) side of the CSCW loop. The leakage integrity of the GCC was found to fail for temperature gradients as high as 100 °C. The use of the GCC on the exit of the test section employed on the CSCW loop was not recommended."]},{"key":"dc:title","label":"Title","values":["Deformation and Stresses Generated on The Bolted Flange Joint Assembly and The Grayloc Clamp Connector at Elevated Temperatures"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Mogri, Mustafa"],"dc:date.accessioned":["2025-04-08T19:17:57Z"],"dc:date.available":["2025-04-08T19:17:57Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Finite element analyses were performed to investigate the leakage and structural integrity of the bolted flange joint assembly (BFJA) and Grayloc clamp connector (GCC), when each assembly was subjected to bolt preload, internal pressure and thermal loadings. The thermal loadings were divided into spatially-uniform and spatially-nonuniform temperatures. The internal pressure for both assemblies was 27 MPa. The BFJA was found to have satisfactory leakage and structural performance for the thermal loadings expected on the low-temperature (260 °C) side of the Carleton Supercritical Water (CSCW) loop. The GCC was found to have satisfactory leakage and structural performance for the thermal loadings expected on the high-temperature (600 °C) side of the CSCW loop. The leakage integrity of the GCC was found to fail for temperature gradients as high as 100 °C. The use of the GCC on the exit of the test section employed on the CSCW loop was not recommended."],"dc:identifier.doi":["10.22215/etd/2014-10104"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38147"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["PHYSICAL SCIENCES Engineering - Mechanical"],"dc:title":["Deformation and Stresses Generated on The Bolted Flange Joint Assembly and The Grayloc Clamp Connector at Elevated Temperatures"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:14:33Z"}