{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38169"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38169","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Ultrasonic Signal Processing for Continuous Measurements of Tissue Displacement and Thickness During Muscle Contraction","abstract":"Tissue displacement and thickness are useful parameters for quantifying muscle function. These parameters can be obtained using ultrasound with high frame rate and reasonable spatial resolution. However, a conventional hand-held ultrasonic probe that is bulky, rigid, and heavy may not be suitable for continuous muscle monitoring during physical activities. This research aimed to measure tissue displacement and thickness variation during muscle contraction using a wearable ultrasonic sensor. However, the energy of the transmitted ultrasonic waves using the wearable ultrasonic sensor is lower than that of a conventional probe. In order to overcome this issue, selected signal processing techniques were applied and compared. It was found in the numerical simulation experiments that the frequency-domain techniques, in particular LQ-factorization, had better tracking accuracy than the time-domain techniques. In the in-vivo experiment, ultrasonic signals were acquired at a forearm during isometric contraction. The tissue boundary displacements and thickness changes were successfully obtained","abstract_html":"Tissue displacement and thickness are useful parameters for quantifying muscle function. These parameters can be obtained using ultrasound with high frame rate and reasonable spatial resolution. However, a conventional hand-held ultrasonic probe that is bulky, rigid, and heavy may not be suitable for continuous muscle monitoring during physical activities. This research aimed to measure tissue displacement and thickness variation during muscle contraction using a wearable ultrasonic sensor. However, the energy of the transmitted ultrasonic waves using the wearable ultrasonic sensor is lower than that of a conventional probe. In order to overcome this issue, selected signal processing techniques were applied and compared. It was found in the numerical simulation experiments that the frequency-domain techniques, in particular LQ-factorization, had better tracking accuracy than the time-domain techniques. In the in-vivo experiment, ultrasonic signals were acquired at a forearm during isometric contraction. The tissue boundary displacements and thickness changes were successfully obtained","abstract_has_math":false,"creators":["Turkistani, Hisham"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T07:05:56Z","subjects":["PHYSICAL SCIENCES Computer Science","PHYSICAL SCIENCES Engineering - System Science","PHYSICAL SCIENCES Engineering - Biomedical"],"languages":["en"],"rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38169"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/38169","href":"https://hdl.handle.net/20.500.14718/38169","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2014-10092","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2014-10092","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38169","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Turkistani, Hisham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:18:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:18:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["PHYSICAL SCIENCES Computer Science","PHYSICAL SCIENCES Engineering - System Science","PHYSICAL SCIENCES Engineering - Biomedical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2014-10092"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38169"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Tissue displacement and thickness are useful parameters for quantifying muscle function. These parameters can be obtained using ultrasound with high frame rate and reasonable spatial resolution. However, a conventional hand-held ultrasonic probe that is bulky, rigid, and heavy may not be suitable for continuous muscle monitoring during physical activities. This research aimed to measure tissue displacement and thickness variation during muscle contraction using a wearable ultrasonic sensor. However, the energy of the transmitted ultrasonic waves using the wearable ultrasonic sensor is lower than that of a conventional probe. In order to overcome this issue, selected signal processing techniques were applied and compared. It was found in the numerical simulation experiments that the frequency-domain techniques, in particular LQ-factorization, had better tracking accuracy than the time-domain techniques. In the in-vivo experiment, ultrasonic signals were acquired at a forearm during isometric contraction. The tissue boundary displacements and thickness changes were successfully obtained"]},{"key":"dc:title","label":"Title","values":["Ultrasonic Signal Processing for Continuous Measurements of Tissue Displacement and Thickness During Muscle Contraction"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Turkistani, Hisham"],"dc:date.accessioned":["2025-04-08T19:18:32Z"],"dc:date.available":["2025-04-08T19:18:32Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Tissue displacement and thickness are useful parameters for quantifying muscle function. These parameters can be obtained using ultrasound with high frame rate and reasonable spatial resolution. However, a conventional hand-held ultrasonic probe that is bulky, rigid, and heavy may not be suitable for continuous muscle monitoring during physical activities. This research aimed to measure tissue displacement and thickness variation during muscle contraction using a wearable ultrasonic sensor. However, the energy of the transmitted ultrasonic waves using the wearable ultrasonic sensor is lower than that of a conventional probe. In order to overcome this issue, selected signal processing techniques were applied and compared. It was found in the numerical simulation experiments that the frequency-domain techniques, in particular LQ-factorization, had better tracking accuracy than the time-domain techniques. In the in-vivo experiment, ultrasonic signals were acquired at a forearm during isometric contraction. The tissue boundary displacements and thickness changes were successfully obtained"],"dc:identifier.doi":["10.22215/etd/2014-10092"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38169"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2014 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["PHYSICAL SCIENCES Computer Science","PHYSICAL SCIENCES Engineering - System Science","PHYSICAL SCIENCES Engineering - Biomedical"],"dc:title":["Ultrasonic Signal Processing for Continuous Measurements of Tissue Displacement and Thickness During Muscle Contraction"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:05:56Z"}