{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38553"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38553","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Electrocardiogram Signal Quality Analysis to Reduce False Alarms in Myocardial Ischemia Monitoring","abstract":"The probability of myocardial ischemia is increased following a non-cardiac surgery, therefore, elevating the incidence of post-operative cardiac events. Myocardial ischemia causes a deviation of ST segment in the electrocardiogram (ECG), enabling targeted administration of β-Blockers; however, utilization of ECG was hindered by false alarms. The objective of this thesis is to develop a system to gate false alarms using the signal quality of the ECG and quality of the ST segment deviation estimate. The system was tested using ECG contaminated with motion artifact noise. The system gated 86% of all false alarms attaining a recall and precision of 0.72 and 0.73, respectively, marking an increase of 0.42 in precision and a decrease of 0.05 in recall from the bedside monitor performance (precision: 0.31, recall: 0.78). The signal quality analysis was extended to an ECG biometrics system, gating 57.8% of false identifications at the loss of 8.14% of true identifications.","abstract_html":"The probability of myocardial ischemia is increased following a non-cardiac surgery, therefore, elevating the incidence of post-operative cardiac events. Myocardial ischemia causes a deviation of ST segment in the electrocardiogram (ECG), enabling targeted administration of β-Blockers; however, utilization of ECG was hindered by false alarms. The objective of this thesis is to develop a system to gate false alarms using the signal quality of the ECG and quality of the ST segment deviation estimate. The system was tested using ECG contaminated with motion artifact noise. The system gated 86% of all false alarms attaining a recall and precision of 0.72 and 0.73, respectively, marking an increase of 0.42 in precision and a decrease of 0.05 in recall from the bedside monitor performance (precision: 0.31, recall: 0.78). The signal quality analysis was extended to an ECG biometrics system, gating 57.8% of false identifications at the loss of 8.14% of true identifications.","abstract_has_math":false,"creators":["Abdelazez, Mohamed Hazem"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T06:57:32Z","subjects":["System analysis","Biomedical engineering","System theory","Electric networks"],"languages":["en"],"rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38553"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/38553","href":"https://hdl.handle.net/20.500.14718/38553","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2016-11599","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2016-11599","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F38553","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38553","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Abdelazez, Mohamed Hazem"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:25:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:25:32Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["System analysis","Biomedical engineering","System theory","Electric networks"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2016-11599"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38553"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The probability of myocardial ischemia is increased following a non-cardiac surgery, therefore, elevating the incidence of post-operative cardiac events. Myocardial ischemia causes a deviation of ST segment in the electrocardiogram (ECG), enabling targeted administration of β-Blockers; however, utilization of ECG was hindered by false alarms. The objective of this thesis is to develop a system to gate false alarms using the signal quality of the ECG and quality of the ST segment deviation estimate. The system was tested using ECG contaminated with motion artifact noise. The system gated 86% of all false alarms attaining a recall and precision of 0.72 and 0.73, respectively, marking an increase of 0.42 in precision and a decrease of 0.05 in recall from the bedside monitor performance (precision: 0.31, recall: 0.78). The signal quality analysis was extended to an ECG biometrics system, gating 57.8% of false identifications at the loss of 8.14% of true identifications."]},{"key":"dc:title","label":"Title","values":["Electrocardiogram Signal Quality Analysis to Reduce False Alarms in Myocardial Ischemia Monitoring"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Abdelazez, Mohamed Hazem"],"dc:date.accessioned":["2025-04-08T19:25:32Z"],"dc:date.available":["2025-04-08T19:25:32Z"],"dc:date.issued":["2016"],"dc:description.abstract":["The probability of myocardial ischemia is increased following a non-cardiac surgery, therefore, elevating the incidence of post-operative cardiac events. Myocardial ischemia causes a deviation of ST segment in the electrocardiogram (ECG), enabling targeted administration of β-Blockers; however, utilization of ECG was hindered by false alarms. The objective of this thesis is to develop a system to gate false alarms using the signal quality of the ECG and quality of the ST segment deviation estimate. The system was tested using ECG contaminated with motion artifact noise. The system gated 86% of all false alarms attaining a recall and precision of 0.72 and 0.73, respectively, marking an increase of 0.42 in precision and a decrease of 0.05 in recall from the bedside monitor performance (precision: 0.31, recall: 0.78). The signal quality analysis was extended to an ECG biometrics system, gating 57.8% of false identifications at the loss of 8.14% of true identifications."],"dc:identifier.doi":["10.22215/etd/2016-11599"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38553"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["System analysis","Biomedical engineering","System theory","Electric networks"],"dc:title":["Electrocardiogram Signal Quality Analysis to Reduce False Alarms in Myocardial Ischemia Monitoring"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:57:32Z"}