{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38626"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38626","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Development of a Tunable Diode Laser Absorption Spectroscopy Mass-Flux Sensor for Quantifying Hydrocarbon Storage Tank Venting","abstract":"Fixed-roof liquid hydrocarbon storage tanks are a recognized source of volatile organic compounds. However, current emissions estimates suffer from a lack of reliable models. This work presents the development and characterization of an intrinsically safe, low velocity mass-flux sensor for monitoring storage tank venting. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulation targeting oxygen within the tank vent line. Similar sensors have been successfully used to measure high velocity flows. Sensor design, optimum operational parameters, and indoor characterization results are presented. An oxygen concentration precision of 0.11% absolute was achieved over the tested range of 2.5-21%. For measurements at 21% O2, a velocity standard deviation of 0.24 m/s for 30-s average measurements was achieved, which could be improved to 0.07 m/s with a 10-minute interval drift correction. However, velocity measurement accuracy was poor at lower O2 concentrations.","abstract_html":"Fixed-roof liquid hydrocarbon storage tanks are a recognized source of volatile organic compounds. However, current emissions estimates suffer from a lack of reliable models. This work presents the development and characterization of an intrinsically safe, low velocity mass-flux sensor for monitoring storage tank venting. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulation targeting oxygen within the tank vent line. Similar sensors have been successfully used to measure high velocity flows. Sensor design, optimum operational parameters, and indoor characterization results are presented. An oxygen concentration precision of 0.11% absolute was achieved over the tested range of 2.5-21%. For measurements at 21% O2, a velocity standard deviation of 0.24 m/s for 30-s average measurements was achieved, which could be improved to 0.07 m/s with a 10-minute interval drift correction. However, velocity measurement accuracy was poor at lower O2 concentrations.","abstract_has_math":false,"creators":["Festa-Bianchet, Simon Alberto"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:05:39Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38626"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/38626","href":"https://hdl.handle.net/20.500.14718/38626","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2016-11617","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2016-11617","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38626","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Festa-Bianchet, Simon Alberto"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:26:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:26:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2016-11617"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38626"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fixed-roof liquid hydrocarbon storage tanks are a recognized source of volatile organic compounds. However, current emissions estimates suffer from a lack of reliable models. This work presents the development and characterization of an intrinsically safe, low velocity mass-flux sensor for monitoring storage tank venting. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulation targeting oxygen within the tank vent line. Similar sensors have been successfully used to measure high velocity flows. Sensor design, optimum operational parameters, and indoor characterization results are presented. An oxygen concentration precision of 0.11% absolute was achieved over the tested range of 2.5-21%. For measurements at 21% O2, a velocity standard deviation of 0.24 m/s for 30-s average measurements was achieved, which could be improved to 0.07 m/s with a 10-minute interval drift correction. However, velocity measurement accuracy was poor at lower O2 concentrations."]},{"key":"dc:title","label":"Title","values":["Development of a Tunable Diode Laser Absorption Spectroscopy Mass-Flux Sensor for Quantifying Hydrocarbon Storage Tank Venting"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Festa-Bianchet, Simon Alberto"],"dc:date.accessioned":["2025-04-08T19:26:52Z"],"dc:date.available":["2025-04-08T19:26:52Z"],"dc:date.issued":["2016"],"dc:description.abstract":["Fixed-roof liquid hydrocarbon storage tanks are a recognized source of volatile organic compounds. However, current emissions estimates suffer from a lack of reliable models. This work presents the development and characterization of an intrinsically safe, low velocity mass-flux sensor for monitoring storage tank venting. The sensor is based on tunable diode laser absorption spectroscopy (TDLAS) with wavelength modulation targeting oxygen within the tank vent line. Similar sensors have been successfully used to measure high velocity flows. Sensor design, optimum operational parameters, and indoor characterization results are presented. An oxygen concentration precision of 0.11% absolute was achieved over the tested range of 2.5-21%. For measurements at 21% O2, a velocity standard deviation of 0.24 m/s for 30-s average measurements was achieved, which could be improved to 0.07 m/s with a 10-minute interval drift correction. However, velocity measurement accuracy was poor at lower O2 concentrations."],"dc:identifier.doi":["10.22215/etd/2016-11617"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38626"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Development of a Tunable Diode Laser Absorption Spectroscopy Mass-Flux Sensor for Quantifying Hydrocarbon Storage Tank Venting"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:05:39Z"}