{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38825"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38825","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Analysis of Radiographic Contrast Markers for X-ray Digital Image Correlation of Tissue-Simulants Under Dynamic Load","abstract":"The study of traumatic brain injury is critical to the improvement of protective equipment. Numerical models of brain deformation require real-world data for validation. In preparation for upcoming cadaver studies, a novel method of measuring displacement and strain fields of optically inaccessible internal planes using high-speed X-ray, embedded contrast markers and digital image correlation (DIC) is presented herein. An uncoupled scintillator and optimally-selected high-speed camera enable continuous X-ray imaging through a human head at 10,000 fps. As varying composition creates radiographic contrast, contrast within a human brain is limited, therefore, artificial contrast markers are required. Markers must be dynamically coupled to the bulk material and provide sufficient X-ray contrast. An analytical tool was developed to design of contrast markers. The impact of contrast-to-noise ratio and out-of-plane motion on DIC accuracy were quantified. Finally, a feasibility study using a biofidelic headform subjected to a NOCSAE drop test is presented.","abstract_html":"The study of traumatic brain injury is critical to the improvement of protective equipment. Numerical models of brain deformation require real-world data for validation. In preparation for upcoming cadaver studies, a novel method of measuring displacement and strain fields of optically inaccessible internal planes using high-speed X-ray, embedded contrast markers and digital image correlation (DIC) is presented herein. An uncoupled scintillator and optimally-selected high-speed camera enable continuous X-ray imaging through a human head at 10,000 fps. As varying composition creates radiographic contrast, contrast within a human brain is limited, therefore, artificial contrast markers are required. Markers must be dynamically coupled to the bulk material and provide sufficient X-ray contrast. An analytical tool was developed to design of contrast markers. The impact of contrast-to-noise ratio and out-of-plane motion on DIC accuracy were quantified. Finally, a feasibility study using a biofidelic headform subjected to a NOCSAE drop test is presented.","abstract_has_math":false,"creators":["Magnan, Stephane"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T06:53:20Z","subjects":["Mechanical engineering","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13242"],"render_values":[{"text":"10.22215/etd/2018-13242","href":"https://doi.org/10.22215/etd/2018-13242","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/38825","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/38825","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38825","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Magnan, Stephane"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:30:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:30:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13242"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38825"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The study of traumatic brain injury is critical to the improvement of protective equipment. Numerical models of brain deformation require real-world data for validation. In preparation for upcoming cadaver studies, a novel method of measuring displacement and strain fields of optically inaccessible internal planes using high-speed X-ray, embedded contrast markers and digital image correlation (DIC) is presented herein. An uncoupled scintillator and optimally-selected high-speed camera enable continuous X-ray imaging through a human head at 10,000 fps. As varying composition creates radiographic contrast, contrast within a human brain is limited, therefore, artificial contrast markers are required. Markers must be dynamically coupled to the bulk material and provide sufficient X-ray contrast. An analytical tool was developed to design of contrast markers. The impact of contrast-to-noise ratio and out-of-plane motion on DIC accuracy were quantified. Finally, a feasibility study using a biofidelic headform subjected to a NOCSAE drop test is presented."]},{"key":"dc:title","label":"Title","values":["Analysis of Radiographic Contrast Markers for X-ray Digital Image Correlation of Tissue-Simulants Under Dynamic Load"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Magnan, Stephane"],"dc:date.accessioned":["2025-04-08T19:30:44Z"],"dc:date.available":["2025-04-08T19:30:44Z"],"dc:date.issued":["2018"],"dc:description.abstract":["The study of traumatic brain injury is critical to the improvement of protective equipment. Numerical models of brain deformation require real-world data for validation. In preparation for upcoming cadaver studies, a novel method of measuring displacement and strain fields of optically inaccessible internal planes using high-speed X-ray, embedded contrast markers and digital image correlation (DIC) is presented herein. An uncoupled scintillator and optimally-selected high-speed camera enable continuous X-ray imaging through a human head at 10,000 fps. As varying composition creates radiographic contrast, contrast within a human brain is limited, therefore, artificial contrast markers are required. Markers must be dynamically coupled to the bulk material and provide sufficient X-ray contrast. An analytical tool was developed to design of contrast markers. The impact of contrast-to-noise ratio and out-of-plane motion on DIC accuracy were quantified. Finally, a feasibility study using a biofidelic headform subjected to a NOCSAE drop test is presented."],"dc:identifier.doi":["10.22215/etd/2018-13242"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38825"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering","Biomedical engineering"],"dc:title":["Analysis of Radiographic Contrast Markers for X-ray Digital Image Correlation of Tissue-Simulants Under Dynamic Load"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:53:20Z"}