{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38859"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38859","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"An Experimental Evaluation of Fixed and Fluidized Beds of Zeolite 13X for the Application of Compact Thermal Energy Storage","abstract":"A bench-scale adsorption-based TES system was designed, constructed, instrumented, and commissioned. In demonstrating this technology, the objective of this research was to obtain thermodynamic data for the adsorption of water vapour onto zeolite 13X under fluidization to evaluate fluidized beds as potential reactor or adsorber designs. Multiple adsorption experiments were performed on samples of an 8x12 and 60x65 mesh zeolite 13X molecular sieve, comparing the effects of air flow rate and concentration of water vapour on the breakthrough and temperature lift on the energy density of fixed and fluidized adsorbent beds. The concentraion of water vapour at the inlet or relative humidity of the air was shown to be one of the most significant parameters for controlling the delivery temperature of each bed. The results of the experimental data are were then considered in scaling the adsorbent beds to meet a range of heating loads.","abstract_html":"A bench-scale adsorption-based TES system was designed, constructed, instrumented, and commissioned. In demonstrating this technology, the objective of this research was to obtain thermodynamic data for the adsorption of water vapour onto zeolite 13X under fluidization to evaluate fluidized beds as potential reactor or adsorber designs. Multiple adsorption experiments were performed on samples of an 8x12 and 60x65 mesh zeolite 13X molecular sieve, comparing the effects of air flow rate and concentration of water vapour on the breakthrough and temperature lift on the energy density of fixed and fluidized adsorbent beds. The concentraion of water vapour at the inlet or relative humidity of the air was shown to be one of the most significant parameters for controlling the delivery temperature of each bed. The results of the experimental data are were then considered in scaling the adsorbent beds to meet a range of heating loads.","abstract_has_math":false,"creators":["Bardy, Dylan Alexander"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Sustainable Energy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T07:11:36Z","subjects":["Chemical engineering","Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13325"],"render_values":[{"text":"10.22215/etd/2018-13325","href":"https://doi.org/10.22215/etd/2018-13325","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/38859","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/38859","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38859","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bardy, Dylan Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:31:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:31:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Sustainable Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Chemical engineering","Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13325"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38859"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A bench-scale adsorption-based TES system was designed, constructed, instrumented, and commissioned. In demonstrating this technology, the objective of this research was to obtain thermodynamic data for the adsorption of water vapour onto zeolite 13X under fluidization to evaluate fluidized beds as potential reactor or adsorber designs. Multiple adsorption experiments were performed on samples of an 8x12 and 60x65 mesh zeolite 13X molecular sieve, comparing the effects of air flow rate and concentration of water vapour on the breakthrough and temperature lift on the energy density of fixed and fluidized adsorbent beds. The concentraion of water vapour at the inlet or relative humidity of the air was shown to be one of the most significant parameters for controlling the delivery temperature of each bed. The results of the experimental data are were then considered in scaling the adsorbent beds to meet a range of heating loads."]},{"key":"dc:title","label":"Title","values":["An Experimental Evaluation of Fixed and Fluidized Beds of Zeolite 13X for the Application of Compact Thermal Energy Storage"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bardy, Dylan Alexander"],"dc:date.accessioned":["2025-04-08T19:31:18Z"],"dc:date.available":["2025-04-08T19:31:18Z"],"dc:date.issued":["2018"],"dc:description.abstract":["A bench-scale adsorption-based TES system was designed, constructed, instrumented, and commissioned. In demonstrating this technology, the objective of this research was to obtain thermodynamic data for the adsorption of water vapour onto zeolite 13X under fluidization to evaluate fluidized beds as potential reactor or adsorber designs. Multiple adsorption experiments were performed on samples of an 8x12 and 60x65 mesh zeolite 13X molecular sieve, comparing the effects of air flow rate and concentration of water vapour on the breakthrough and temperature lift on the energy density of fixed and fluidized adsorbent beds. The concentraion of water vapour at the inlet or relative humidity of the air was shown to be one of the most significant parameters for controlling the delivery temperature of each bed. The results of the experimental data are were then considered in scaling the adsorbent beds to meet a range of heating loads."],"dc:identifier.doi":["10.22215/etd/2018-13325"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38859"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Chemical engineering","Mechanical engineering"],"dc:title":["An Experimental Evaluation of Fixed and Fluidized Beds of Zeolite 13X for the Application of Compact Thermal Energy Storage"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Sustainable Energy"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:11:36Z"}