{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38878"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38878","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Continuous Monitoring of Mechanical Properties of Plantar Soft Tissue Using Wearable Ultrasonic and Force Sensors for Diabetic Patients","abstract":"Diabetic foot ulceration is one of the complications of diabetes mellitus. One of the reasons of diabetic ulcers is neuropathy in which the nerves of foot are damaged and diabetic patients cannot feel the pain. Thus it is possible that they injure their feet without their knowledge and undetected injuries lead to the foot ulcer. Research works indicate that ulcers begin from the underlying tissue where soft tissues become stiffer. In this study, a wearable ultrasonic stiffness sensor for continuous monitoring of mechanical properties of soft tissue was developed and tested. The performance of the developed system was evaluated using soft tissue mimicking phantoms. In-vivo experiment was conducted while the participant was stepping. Pressure-displacement curve for plantar tissue at heel part was obtained for one compression-release cycle where certain tissue mechanical properties such as Young’s modulus and stiffness are computable.","abstract_html":"Diabetic foot ulceration is one of the complications of diabetes mellitus. One of the reasons of diabetic ulcers is neuropathy in which the nerves of foot are damaged and diabetic patients cannot feel the pain. Thus it is possible that they injure their feet without their knowledge and undetected injuries lead to the foot ulcer. Research works indicate that ulcers begin from the underlying tissue where soft tissues become stiffer. In this study, a wearable ultrasonic stiffness sensor for continuous monitoring of mechanical properties of soft tissue was developed and tested. The performance of the developed system was evaluated using soft tissue mimicking phantoms. In-vivo experiment was conducted while the participant was stepping. Pressure-displacement curve for plantar tissue at heel part was obtained for one compression-release cycle where certain tissue mechanical properties such as Young’s modulus and stiffness are computable.","abstract_has_math":false,"creators":["Zabihollahy, Fatemeh"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T06:53:56Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2016-11505"],"render_values":[{"text":"10.22215/etd/2016-11505","href":"https://doi.org/10.22215/etd/2016-11505","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/38878","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/38878","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38878","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Zabihollahy, Fatemeh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:31:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:31:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2016-11505"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38878"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Diabetic foot ulceration is one of the complications of diabetes mellitus. One of the reasons of diabetic ulcers is neuropathy in which the nerves of foot are damaged and diabetic patients cannot feel the pain. Thus it is possible that they injure their feet without their knowledge and undetected injuries lead to the foot ulcer. Research works indicate that ulcers begin from the underlying tissue where soft tissues become stiffer. In this study, a wearable ultrasonic stiffness sensor for continuous monitoring of mechanical properties of soft tissue was developed and tested. The performance of the developed system was evaluated using soft tissue mimicking phantoms. In-vivo experiment was conducted while the participant was stepping. Pressure-displacement curve for plantar tissue at heel part was obtained for one compression-release cycle where certain tissue mechanical properties such as Young’s modulus and stiffness are computable."]},{"key":"dc:title","label":"Title","values":["Continuous Monitoring of Mechanical Properties of Plantar Soft Tissue Using Wearable Ultrasonic and Force Sensors for Diabetic Patients"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Zabihollahy, Fatemeh"],"dc:date.accessioned":["2025-04-08T19:31:36Z"],"dc:date.available":["2025-04-08T19:31:36Z"],"dc:date.issued":["2016"],"dc:description.abstract":["Diabetic foot ulceration is one of the complications of diabetes mellitus. One of the reasons of diabetic ulcers is neuropathy in which the nerves of foot are damaged and diabetic patients cannot feel the pain. Thus it is possible that they injure their feet without their knowledge and undetected injuries lead to the foot ulcer. Research works indicate that ulcers begin from the underlying tissue where soft tissues become stiffer. In this study, a wearable ultrasonic stiffness sensor for continuous monitoring of mechanical properties of soft tissue was developed and tested. The performance of the developed system was evaluated using soft tissue mimicking phantoms. In-vivo experiment was conducted while the participant was stepping. Pressure-displacement curve for plantar tissue at heel part was obtained for one compression-release cycle where certain tissue mechanical properties such as Young’s modulus and stiffness are computable."],"dc:identifier.doi":["10.22215/etd/2016-11505"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38878"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Continuous Monitoring of Mechanical Properties of Plantar Soft Tissue Using Wearable Ultrasonic and Force Sensors for Diabetic Patients"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:53:56Z"}