{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/38977"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/38977","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Analysis of Contact Pressure for Monitoring Body Fluid Distribution","abstract":"Fluid distribution is a key indicator for diseases that become more prevalent as we age, such as congestive heart failure (CHF) and nocturia. Current methods to monitor fluid distribution rely on infrequent and often self-report measures, which are unreliable. This thesis aims to develop and evaluate a continuous, unobtrusive, and non-invasive alternative method using pressure sensitive mats (PSM) to accurately measure fluid distribution.A series of four increasingly complex experiments were performed. The first three experiments established that PSMs are sufficiently sensitive to detect small variations in mass typical of fluid retention observed in CHF. The final experiment and corresponding algorithm aimed to differentiate when an individual exits the bed to: do nothing, void their bladder, or drink water. Based on the results from a single participant in three postures (prone, supine, and side), the system could identify bed exits associated with large voids and drinking events (p < 0.05).","abstract_html":"Fluid distribution is a key indicator for diseases that become more prevalent as we age, such as congestive heart failure (CHF) and nocturia. Current methods to monitor fluid distribution rely on infrequent and often self-report measures, which are unreliable. This thesis aims to develop and evaluate a continuous, unobtrusive, and non-invasive alternative method using pressure sensitive mats (PSM) to accurately measure fluid distribution.A series of four increasingly complex experiments were performed. The first three experiments established that PSMs are sufficiently sensitive to detect small variations in mass typical of fluid retention observed in CHF. The final experiment and corresponding algorithm aimed to differentiate when an individual exits the bed to: do nothing, void their bladder, or drink water. Based on the results from a single participant in three postures (prone, supine, and side), the system could identify bed exits associated with large voids and drinking events (p &lt; 0.05).","abstract_has_math":false,"creators":["Cohen-McFarlane, Madison"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T07:03:34Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38977"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/38977","href":"https://hdl.handle.net/20.500.14718/38977","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2017-11981","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2017-11981","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F38977","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F38977","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Cohen-McFarlane, Madison"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:33:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:33:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2017-11981"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/38977"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fluid distribution is a key indicator for diseases that become more prevalent as we age, such as congestive heart failure (CHF) and nocturia. Current methods to monitor fluid distribution rely on infrequent and often self-report measures, which are unreliable. This thesis aims to develop and evaluate a continuous, unobtrusive, and non-invasive alternative method using pressure sensitive mats (PSM) to accurately measure fluid distribution.A series of four increasingly complex experiments were performed. The first three experiments established that PSMs are sufficiently sensitive to detect small variations in mass typical of fluid retention observed in CHF. The final experiment and corresponding algorithm aimed to differentiate when an individual exits the bed to: do nothing, void their bladder, or drink water. Based on the results from a single participant in three postures (prone, supine, and side), the system could identify bed exits associated with large voids and drinking events (p < 0.05)."]},{"key":"dc:title","label":"Title","values":["Analysis of Contact Pressure for Monitoring Body Fluid Distribution"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Cohen-McFarlane, Madison"],"dc:date.accessioned":["2025-04-08T19:33:25Z"],"dc:date.available":["2025-04-08T19:33:25Z"],"dc:date.issued":["2017"],"dc:description.abstract":["Fluid distribution is a key indicator for diseases that become more prevalent as we age, such as congestive heart failure (CHF) and nocturia. Current methods to monitor fluid distribution rely on infrequent and often self-report measures, which are unreliable. This thesis aims to develop and evaluate a continuous, unobtrusive, and non-invasive alternative method using pressure sensitive mats (PSM) to accurately measure fluid distribution.A series of four increasingly complex experiments were performed. The first three experiments established that PSMs are sufficiently sensitive to detect small variations in mass typical of fluid retention observed in CHF. The final experiment and corresponding algorithm aimed to differentiate when an individual exits the bed to: do nothing, void their bladder, or drink water. Based on the results from a single participant in three postures (prone, supine, and side), the system could identify bed exits associated with large voids and drinking events (p < 0.05)."],"dc:identifier.doi":["10.22215/etd/2017-11981"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/38977"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Analysis of Contact Pressure for Monitoring Body Fluid Distribution"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:03:34Z"}