{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39314"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39314","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Monitoring Breathing Using a Doppler Radar","abstract":"Correctional institutions are looking to adopt a non-obtrusive method for monitoring the vital signs of inmates in Canada. Doppler radar has been previously investigated as a potential method of vital signs detection and monitoring. This thesis presents an algorithm which uses the baseband output signal received by a Doppler radar to estimate the breathing rate from the detected motion associated with breathing. A reliability measure is provided with breathing rate estimates through the analysis of various signal quality indices. Results demonstrate that the algorithm is able to estimate the subject’s breathing rate (with high reliability) when the subject is motionless and breathing normally (mean error of 6 breaths per minute). The algorithm cannot accurately estimate the breathing rate when the subject is moving or holding their breath (mean error of 21 breaths per minute). During breath holds, it was found that the algorithm can likely estimate the subject’s heart rate.","abstract_html":"Correctional institutions are looking to adopt a non-obtrusive method for monitoring the vital signs of inmates in Canada. Doppler radar has been previously investigated as a potential method of vital signs detection and monitoring. This thesis presents an algorithm which uses the baseband output signal received by a Doppler radar to estimate the breathing rate from the detected motion associated with breathing. A reliability measure is provided with breathing rate estimates through the analysis of various signal quality indices. Results demonstrate that the algorithm is able to estimate the subject’s breathing rate (with high reliability) when the subject is motionless and breathing normally (mean error of 6 breaths per minute). The algorithm cannot accurately estimate the breathing rate when the subject is moving or holding their breath (mean error of 21 breaths per minute). During breath holds, it was found that the algorithm can likely estimate the subject’s heart rate.","abstract_has_math":false,"creators":["Tworzydlo, Philip"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T06:51:48Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39314"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/39314","href":"https://hdl.handle.net/20.500.14718/39314","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2016-11230","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2016-11230","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F39314","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39314","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Tworzydlo, Philip"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:39:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:39:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2016-11230"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39314"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Correctional institutions are looking to adopt a non-obtrusive method for monitoring the vital signs of inmates in Canada. Doppler radar has been previously investigated as a potential method of vital signs detection and monitoring. This thesis presents an algorithm which uses the baseband output signal received by a Doppler radar to estimate the breathing rate from the detected motion associated with breathing. A reliability measure is provided with breathing rate estimates through the analysis of various signal quality indices. Results demonstrate that the algorithm is able to estimate the subject’s breathing rate (with high reliability) when the subject is motionless and breathing normally (mean error of 6 breaths per minute). The algorithm cannot accurately estimate the breathing rate when the subject is moving or holding their breath (mean error of 21 breaths per minute). During breath holds, it was found that the algorithm can likely estimate the subject’s heart rate."]},{"key":"dc:title","label":"Title","values":["Monitoring Breathing Using a Doppler Radar"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Tworzydlo, Philip"],"dc:date.accessioned":["2025-04-08T19:39:19Z"],"dc:date.available":["2025-04-08T19:39:19Z"],"dc:date.issued":["2016"],"dc:description.abstract":["Correctional institutions are looking to adopt a non-obtrusive method for monitoring the vital signs of inmates in Canada. Doppler radar has been previously investigated as a potential method of vital signs detection and monitoring. This thesis presents an algorithm which uses the baseband output signal received by a Doppler radar to estimate the breathing rate from the detected motion associated with breathing. A reliability measure is provided with breathing rate estimates through the analysis of various signal quality indices. Results demonstrate that the algorithm is able to estimate the subject’s breathing rate (with high reliability) when the subject is motionless and breathing normally (mean error of 6 breaths per minute). The algorithm cannot accurately estimate the breathing rate when the subject is moving or holding their breath (mean error of 21 breaths per minute). During breath holds, it was found that the algorithm can likely estimate the subject’s heart rate."],"dc:identifier.doi":["10.22215/etd/2016-11230"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39314"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2016 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Monitoring Breathing Using a Doppler Radar"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:51:48Z"}