{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39321"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39321","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"An Evaluation of Model Predictive Control of Automated Shading to Optimize Passive Solar Gains","abstract":"Passive houses are prone to overheating, even sometimes in the winter. Model predictive control (MPC) of automated window blinds has proved to be effective at managing solar gains to reduce the thermal loads in buildings. MPC involves predicting a system's future response to several control inputs to determine the best current control decision. This is beneficial in buildings, which experience a delayed thermal response to solar gains.This thesis details a framework for MPC of automated blinds to optimize passive solar gains in a single-family home. Building performance simulations (BPS) were used to predict the interactions between the blind positions and the heating and cooling loads. Optimizations were performed to minimize the combined heating and cooling loads. The MPC's performance was simulated and compared to a rule-based controller (RBC), which is the standard practice in blind automation. Energy savings of up to 36% were recorded in comparison to the RBC.","abstract_html":"Passive houses are prone to overheating, even sometimes in the winter. Model predictive control (MPC) of automated window blinds has proved to be effective at managing solar gains to reduce the thermal loads in buildings. MPC involves predicting a system&#x27;s future response to several control inputs to determine the best current control decision. This is beneficial in buildings, which experience a delayed thermal response to solar gains.This thesis details a framework for MPC of automated blinds to optimize passive solar gains in a single-family home. Building performance simulations (BPS) were used to predict the interactions between the blind positions and the heating and cooling loads. Optimizations were performed to minimize the combined heating and cooling loads. The MPC&#x27;s performance was simulated and compared to a rule-based controller (RBC), which is the standard practice in blind automation. Energy savings of up to 36% were recorded in comparison to the RBC.","abstract_has_math":false,"creators":["Lawal, Nuriat Tiwatayo"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Sustainable Energy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-19T07:03:10Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39321"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/39321","href":"https://hdl.handle.net/20.500.14718/39321","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2015-11191","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2015-11191","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F39321","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39321","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Joseph A. Clarke (Figure contributor)"]},{"key":"dc:creator","label":"Author","values":["Lawal, Nuriat Tiwatayo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:39:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:39:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Sustainable Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2015-11191"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39321"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Passive houses are prone to overheating, even sometimes in the winter. Model predictive control (MPC) of automated window blinds has proved to be effective at managing solar gains to reduce the thermal loads in buildings. MPC involves predicting a system's future response to several control inputs to determine the best current control decision. This is beneficial in buildings, which experience a delayed thermal response to solar gains.This thesis details a framework for MPC of automated blinds to optimize passive solar gains in a single-family home. Building performance simulations (BPS) were used to predict the interactions between the blind positions and the heating and cooling loads. Optimizations were performed to minimize the combined heating and cooling loads. The MPC's performance was simulated and compared to a rule-based controller (RBC), which is the standard practice in blind automation. Energy savings of up to 36% were recorded in comparison to the RBC."]},{"key":"dc:title","label":"Title","values":["An Evaluation of Model Predictive Control of Automated Shading to Optimize Passive Solar Gains"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.other":["Joseph A. Clarke (Figure contributor)"],"dc:creator":["Lawal, Nuriat Tiwatayo"],"dc:date.accessioned":["2025-04-08T19:39:27Z"],"dc:date.available":["2025-04-08T19:39:27Z"],"dc:date.issued":["2015"],"dc:description.abstract":["Passive houses are prone to overheating, even sometimes in the winter. Model predictive control (MPC) of automated window blinds has proved to be effective at managing solar gains to reduce the thermal loads in buildings. MPC involves predicting a system's future response to several control inputs to determine the best current control decision. This is beneficial in buildings, which experience a delayed thermal response to solar gains.This thesis details a framework for MPC of automated blinds to optimize passive solar gains in a single-family home. Building performance simulations (BPS) were used to predict the interactions between the blind positions and the heating and cooling loads. Optimizations were performed to minimize the combined heating and cooling loads. The MPC's performance was simulated and compared to a rule-based controller (RBC), which is the standard practice in blind automation. Energy savings of up to 36% were recorded in comparison to the RBC."],"dc:identifier.doi":["10.22215/etd/2015-11191"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39321"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2015 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["An Evaluation of Model Predictive Control of Automated Shading to Optimize Passive Solar Gains"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Sustainable Energy"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:03:10Z"}