{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39575"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39575","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Framework for Ensuring the Ongoing Maintenance of Existing Buildings Applied to a National Capital Commission Case Study","abstract":"All buildings deteriorate over time. If neglected, the severity of their deterioration and the repair work required increases. The deterioration of buildings, however, can be slowed with ongoing maintenance. This research created an informative, user-friendly, and uniform workflow that can ensure the ongoing maintenance of buildings, with Header House as a case study. The framework begins with research and surveying the building. As-built and condition drawings and a BIM are produced. A seismic analysis was also conducted for a range of values and connectivity conditions. The drift of the building was not sensitive to these range cases, while the acceleration and base shear were affected by the change in stiffness. The results determined that Header House requires no seismic interventions. A monitoring program and maintenance plan were then created based on the information gathered. The process is repeated every five years to ensure that the building continues to be maintained.","abstract_html":"All buildings deteriorate over time. If neglected, the severity of their deterioration and the repair work required increases. The deterioration of buildings, however, can be slowed with ongoing maintenance. This research created an informative, user-friendly, and uniform workflow that can ensure the ongoing maintenance of buildings, with Header House as a case study. The framework begins with research and surveying the building. As-built and condition drawings and a BIM are produced. A seismic analysis was also conducted for a range of values and connectivity conditions. The drift of the building was not sensitive to these range cases, while the acceleration and base shear were affected by the change in stiffness. The results determined that Header House requires no seismic interventions. A monitoring program and maintenance plan were then created based on the information gathered. The process is repeated every five years to ensure that the building continues to be maintained.","abstract_has_math":false,"creators":["Dobrotescu, Raluca Michaela"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Civil","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T07:05:39Z","subjects":["Civil engineering","Architecture"],"languages":["en"],"rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39575"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/39575","href":"https://hdl.handle.net/20.500.14718/39575","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2018-13254","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2018-13254","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F39575","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39575","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dobrotescu, Raluca Michaela"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:44:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:44:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Civil"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering","Architecture"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13254"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39575"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["All buildings deteriorate over time. If neglected, the severity of their deterioration and the repair work required increases. The deterioration of buildings, however, can be slowed with ongoing maintenance. This research created an informative, user-friendly, and uniform workflow that can ensure the ongoing maintenance of buildings, with Header House as a case study. The framework begins with research and surveying the building. As-built and condition drawings and a BIM are produced. A seismic analysis was also conducted for a range of values and connectivity conditions. The drift of the building was not sensitive to these range cases, while the acceleration and base shear were affected by the change in stiffness. The results determined that Header House requires no seismic interventions. A monitoring program and maintenance plan were then created based on the information gathered. The process is repeated every five years to ensure that the building continues to be maintained."]},{"key":"dc:title","label":"Title","values":["Framework for Ensuring the Ongoing Maintenance of Existing Buildings Applied to a National Capital Commission Case Study"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Dobrotescu, Raluca Michaela"],"dc:date.accessioned":["2025-04-08T19:44:12Z"],"dc:date.available":["2025-04-08T19:44:12Z"],"dc:date.issued":["2018"],"dc:description.abstract":["All buildings deteriorate over time. If neglected, the severity of their deterioration and the repair work required increases. The deterioration of buildings, however, can be slowed with ongoing maintenance. This research created an informative, user-friendly, and uniform workflow that can ensure the ongoing maintenance of buildings, with Header House as a case study. The framework begins with research and surveying the building. As-built and condition drawings and a BIM are produced. A seismic analysis was also conducted for a range of values and connectivity conditions. The drift of the building was not sensitive to these range cases, while the acceleration and base shear were affected by the change in stiffness. The results determined that Header House requires no seismic interventions. A monitoring program and maintenance plan were then created based on the information gathered. The process is repeated every five years to ensure that the building continues to be maintained."],"dc:identifier.doi":["10.22215/etd/2018-13254"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39575"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering","Architecture"],"dc:title":["Framework for Ensuring the Ongoing Maintenance of Existing Buildings Applied to a National Capital Commission Case Study"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Civil"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:05:39Z"}