{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39595"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39595","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Effects of Sensors, Age, and Gender on Fingerprint Image Quality","abstract":"The performance of the widely used fingerprint recognition system is heavily influenced by fingerprint quality which in turn is impacted by different factors. Many different algorithms were developed to measure fingerprint quality. This thesis analyzes the impact of different sensors, fingerprint quality algorithms and demographic factors on fingerprint image quality. Three different fingerprint quality algorithms are tested: vendor specific ones from each sensor manufacturer, NFIQ1 and NFIQ2. Our results showed that fingerprint quality decreases with age and males have better fingerprint quality than females on most sensors. The multispectral sensor has the best and stable fingerprint image quality. NFIQ2 worked well with all the tested sensors while NFIQ1 produced anomalous results on sensor 2, 3 and 9. Vendor quality scores from some sensors are either constant or not usable. These findings can help in selecting sensors for biometric systems with targeted subjects and in improving fingerprint sensor design","abstract_html":"The performance of the widely used fingerprint recognition system is heavily influenced by fingerprint quality which in turn is impacted by different factors. Many different algorithms were developed to measure fingerprint quality. This thesis analyzes the impact of different sensors, fingerprint quality algorithms and demographic factors on fingerprint image quality. Three different fingerprint quality algorithms are tested: vendor specific ones from each sensor manufacturer, NFIQ1 and NFIQ2. Our results showed that fingerprint quality decreases with age and males have better fingerprint quality than females on most sensors. The multispectral sensor has the best and stable fingerprint image quality. NFIQ2 worked well with all the tested sensors while NFIQ1 produced anomalous results on sensor 2, 3 and 9. Vendor quality scores from some sensors are either constant or not usable. These findings can help in selecting sensors for biometric systems with targeted subjects and in improving fingerprint sensor design","abstract_has_math":false,"creators":["Yang, Rong"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T07:10:07Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13180"],"render_values":[{"text":"10.22215/etd/2018-13180","href":"https://doi.org/10.22215/etd/2018-13180","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/39595","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/39595","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39595","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yang, Rong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:44:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:44:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13180"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39595"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The performance of the widely used fingerprint recognition system is heavily influenced by fingerprint quality which in turn is impacted by different factors. Many different algorithms were developed to measure fingerprint quality. This thesis analyzes the impact of different sensors, fingerprint quality algorithms and demographic factors on fingerprint image quality. Three different fingerprint quality algorithms are tested: vendor specific ones from each sensor manufacturer, NFIQ1 and NFIQ2. Our results showed that fingerprint quality decreases with age and males have better fingerprint quality than females on most sensors. The multispectral sensor has the best and stable fingerprint image quality. NFIQ2 worked well with all the tested sensors while NFIQ1 produced anomalous results on sensor 2, 3 and 9. Vendor quality scores from some sensors are either constant or not usable. These findings can help in selecting sensors for biometric systems with targeted subjects and in improving fingerprint sensor design"]},{"key":"dc:title","label":"Title","values":["Effects of Sensors, Age, and Gender on Fingerprint Image Quality"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Yang, Rong"],"dc:date.accessioned":["2025-04-08T19:44:34Z"],"dc:date.available":["2025-04-08T19:44:34Z"],"dc:date.issued":["2018"],"dc:description.abstract":["The performance of the widely used fingerprint recognition system is heavily influenced by fingerprint quality which in turn is impacted by different factors. Many different algorithms were developed to measure fingerprint quality. This thesis analyzes the impact of different sensors, fingerprint quality algorithms and demographic factors on fingerprint image quality. Three different fingerprint quality algorithms are tested: vendor specific ones from each sensor manufacturer, NFIQ1 and NFIQ2. Our results showed that fingerprint quality decreases with age and males have better fingerprint quality than females on most sensors. The multispectral sensor has the best and stable fingerprint image quality. NFIQ2 worked well with all the tested sensors while NFIQ1 produced anomalous results on sensor 2, 3 and 9. Vendor quality scores from some sensors are either constant or not usable. These findings can help in selecting sensors for biometric systems with targeted subjects and in improving fingerprint sensor design"],"dc:identifier.doi":["10.22215/etd/2018-13180"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39595"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Effects of Sensors, Age, and Gender on Fingerprint Image Quality"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:10:07Z"}