{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39660"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39660","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Neonatal Respiratory Rate Monitoring Using a Pressure-Sensitive Mat","abstract":"Pressure measurement using a Pressure Sensitive Mat (PSM) enables a non-contact approach for monitoring patient vital signs such as respiration rate (RR) and heart rate (HR). Non-contact patient monitoring in Neonatal Intensive Care Units (NICU) can improve the quality of patient care and reduce patient discomfort. A clinical trial was conducted with the Children's Hospital of Eastern Ontario (CHEO) collecting PSM data from 15 patients in three different bed types. Algorithms for estimating RR were developed. The best RR estimation algorithm worked well when the patient is on ventilator support achieving a mean absolute error (MAE) of 3.92 +/- 6.61 bpm on clean data without patient movements or interventions. When the RR estimation algorithm is evaluated on all patients, RR estimation performance is mixed. In particular, very low mass neonates and patients laying on multiple blankets presented challenges for RR estimation.","abstract_html":"Pressure measurement using a Pressure Sensitive Mat (PSM) enables a non-contact approach for monitoring patient vital signs such as respiration rate (RR) and heart rate (HR). Non-contact patient monitoring in Neonatal Intensive Care Units (NICU) can improve the quality of patient care and reduce patient discomfort. A clinical trial was conducted with the Children&#x27;s Hospital of Eastern Ontario (CHEO) collecting PSM data from 15 patients in three different bed types. Algorithms for estimating RR were developed. The best RR estimation algorithm worked well when the patient is on ventilator support achieving a mean absolute error (MAE) of 3.92 +/- 6.61 bpm on clean data without patient movements or interventions. When the RR estimation algorithm is evaluated on all patients, RR estimation performance is mixed. In particular, very low mass neonates and patients laying on multiple blankets presented challenges for RR estimation.","abstract_has_math":false,"creators":["Bekele, Amente Bullo"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T06:59:51Z","subjects":["Electrical engineering","Electric networks","System analysis","System theory","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13457"],"render_values":[{"text":"10.22215/etd/2018-13457","href":"https://doi.org/10.22215/etd/2018-13457","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/39660","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/39660","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39660","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bekele, Amente Bullo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:45:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:45:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Electric networks","System analysis","System theory","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-13457"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39660"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Pressure measurement using a Pressure Sensitive Mat (PSM) enables a non-contact approach for monitoring patient vital signs such as respiration rate (RR) and heart rate (HR). Non-contact patient monitoring in Neonatal Intensive Care Units (NICU) can improve the quality of patient care and reduce patient discomfort. A clinical trial was conducted with the Children's Hospital of Eastern Ontario (CHEO) collecting PSM data from 15 patients in three different bed types. Algorithms for estimating RR were developed. The best RR estimation algorithm worked well when the patient is on ventilator support achieving a mean absolute error (MAE) of 3.92 +/- 6.61 bpm on clean data without patient movements or interventions. When the RR estimation algorithm is evaluated on all patients, RR estimation performance is mixed. In particular, very low mass neonates and patients laying on multiple blankets presented challenges for RR estimation."]},{"key":"dc:title","label":"Title","values":["Neonatal Respiratory Rate Monitoring Using a Pressure-Sensitive Mat"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bekele, Amente Bullo"],"dc:date.accessioned":["2025-04-08T19:45:41Z"],"dc:date.available":["2025-04-08T19:45:41Z"],"dc:date.issued":["2019"],"dc:description.abstract":["Pressure measurement using a Pressure Sensitive Mat (PSM) enables a non-contact approach for monitoring patient vital signs such as respiration rate (RR) and heart rate (HR). Non-contact patient monitoring in Neonatal Intensive Care Units (NICU) can improve the quality of patient care and reduce patient discomfort. A clinical trial was conducted with the Children's Hospital of Eastern Ontario (CHEO) collecting PSM data from 15 patients in three different bed types. Algorithms for estimating RR were developed. The best RR estimation algorithm worked well when the patient is on ventilator support achieving a mean absolute error (MAE) of 3.92 +/- 6.61 bpm on clean data without patient movements or interventions. When the RR estimation algorithm is evaluated on all patients, RR estimation performance is mixed. In particular, very low mass neonates and patients laying on multiple blankets presented challenges for RR estimation."],"dc:identifier.doi":["10.22215/etd/2018-13457"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39660"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Electric networks","System analysis","System theory","Biomedical engineering"],"dc:title":["Neonatal Respiratory Rate Monitoring Using a Pressure-Sensitive Mat"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:59:51Z"}