{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39701"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39701","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Corrosion Behaviour of High-Carbon High-Molybdenum Stellite Alloys in Amine Environment","abstract":"Stellite alloys are cobalt-based alloys which display exceptional mechanical properties, wear and corrosion resistance owing to its unique chemical compositions. Stellite 6, which is used for hardfacing of valve trim components within control valves in boiler feedwater systems, have failed in application where hydrazine and amine derivatives are used. To find a better replacement of Stellite 6 for improved corrosion resistance, 700 series Stellite alloys, including Stellite 706, Stellite 712 and Stellite 720, are proposed, which are high-carbon high-molybdenum Stellite alloys. The corrosion performance of these alloys is studied using various testing methods in morpholine solution with pH 9.5. It is shown that these 700 series Stellite alloys are comparably better than Stellite 6 with respect to oxide film stability, general and localized corrosion resistance. The outcomes of this research suggest that 700 series Stellite alloys are good candidates for replacing Stellite 6.","abstract_html":"Stellite alloys are cobalt-based alloys which display exceptional mechanical properties, wear and corrosion resistance owing to its unique chemical compositions. Stellite 6, which is used for hardfacing of valve trim components within control valves in boiler feedwater systems, have failed in application where hydrazine and amine derivatives are used. To find a better replacement of Stellite 6 for improved corrosion resistance, 700 series Stellite alloys, including Stellite 706, Stellite 712 and Stellite 720, are proposed, which are high-carbon high-molybdenum Stellite alloys. The corrosion performance of these alloys is studied using various testing methods in morpholine solution with pH 9.5. It is shown that these 700 series Stellite alloys are comparably better than Stellite 6 with respect to oxide film stability, general and localized corrosion resistance. The outcomes of this research suggest that 700 series Stellite alloys are good candidates for replacing Stellite 6.","abstract_has_math":false,"creators":["Kamal, Kafeel"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T07:03:10Z","subjects":["Materials science","Analytical chemistry"],"languages":["en"],"rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13448"],"render_values":[{"text":"10.22215/etd/2019-13448","href":"https://doi.org/10.22215/etd/2019-13448","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/39701","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/39701","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39701","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kamal, Kafeel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:46:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:46:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Materials science","Analytical chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13448"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39701"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Stellite alloys are cobalt-based alloys which display exceptional mechanical properties, wear and corrosion resistance owing to its unique chemical compositions. Stellite 6, which is used for hardfacing of valve trim components within control valves in boiler feedwater systems, have failed in application where hydrazine and amine derivatives are used. To find a better replacement of Stellite 6 for improved corrosion resistance, 700 series Stellite alloys, including Stellite 706, Stellite 712 and Stellite 720, are proposed, which are high-carbon high-molybdenum Stellite alloys. The corrosion performance of these alloys is studied using various testing methods in morpholine solution with pH 9.5. It is shown that these 700 series Stellite alloys are comparably better than Stellite 6 with respect to oxide film stability, general and localized corrosion resistance. The outcomes of this research suggest that 700 series Stellite alloys are good candidates for replacing Stellite 6."]},{"key":"dc:title","label":"Title","values":["Corrosion Behaviour of High-Carbon High-Molybdenum Stellite Alloys in Amine Environment"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Kamal, Kafeel"],"dc:date.accessioned":["2025-04-08T19:46:37Z"],"dc:date.available":["2025-04-08T19:46:37Z"],"dc:date.issued":["2019"],"dc:description.abstract":["Stellite alloys are cobalt-based alloys which display exceptional mechanical properties, wear and corrosion resistance owing to its unique chemical compositions. Stellite 6, which is used for hardfacing of valve trim components within control valves in boiler feedwater systems, have failed in application where hydrazine and amine derivatives are used. To find a better replacement of Stellite 6 for improved corrosion resistance, 700 series Stellite alloys, including Stellite 706, Stellite 712 and Stellite 720, are proposed, which are high-carbon high-molybdenum Stellite alloys. The corrosion performance of these alloys is studied using various testing methods in morpholine solution with pH 9.5. It is shown that these 700 series Stellite alloys are comparably better than Stellite 6 with respect to oxide film stability, general and localized corrosion resistance. The outcomes of this research suggest that 700 series Stellite alloys are good candidates for replacing Stellite 6."],"dc:identifier.doi":["10.22215/etd/2019-13448"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39701"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Materials science","Analytical chemistry"],"dc:title":["Corrosion Behaviour of High-Carbon High-Molybdenum Stellite Alloys in Amine Environment"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:03:10Z"}