{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/39965"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/39965","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"The Use of Distributed Acoustic Sensing for 4D Monitoring Using Vertical Seismic Profiles: Results from the Aquistore CO2 Storage Project","abstract":"Distributed acoustic sensing (DAS) is a rapidly developing technology that employs optical fibers to detect acoustic disturbances in the subsurface. The Aquistore CO2 storage project uses time-lapse DAS VSP's to monitor injected CO2 in a deep geological reservoir (>3200 m) beneath the study site near Estevan, Saskatchewan, Canada. Reservoir monitoring is a crucial component to any geological storage project, and aims to ensure the safe and effective containment of the injected fluids, and evaluate the integrity of the storage and sealing units.An assessment of the ability of DAS VSP's to detect the CO2 response has been conducted for the Aquistore site. Prior to injection, fluid flow simulations were performed to predict CO2 distributions in the reservoir. These simulations were used to model the response of the CO2 plume in 2D time-lapse DAS VSP's. The expected responses were compared with estimates of time-lapse noise computed with field data from the baseline survey, and it was demonstrated that the plume would be visible in the reservoir after 27 kt of injection.After 36 kt of CO2 injection, the first monitor dataset was acquired. 4D VSP processing and imaging were applied to produce time-lapse difference volumes of the reservoir. Acceptable repeatability was attained, with normalized root-mean-square (nRMS) values less than 0.4 beneath the observation and injection wells. An anomaly in the lower part of the reservoir near the observation and injection wells was attributed to the replacement of brine with CO2.Updated fluid flow simulations were obtained that better replicated the injection parameters observed at the study site. Forward seismic modeling was then performed for 36 kt and 97 kt injection scenarios that reflected the 3D shot and receiver geometry in the field acquisitions. These data were processed using the same sequence applied to the field data to obtain comparable time-lapse difference volumes. Comparisons between the field and synthetic 36 kt anomalies were used to refine interpretations of the CO2 distribution in the reservoir. However, they also revealed the need to update the geological model to better reproduce the laterally asymmetric plume expansion.","abstract_html":"Distributed acoustic sensing (DAS) is a rapidly developing technology that employs optical fibers to detect acoustic disturbances in the subsurface. The Aquistore CO2 storage project uses time-lapse DAS VSP&#x27;s to monitor injected CO2 in a deep geological reservoir (&gt;3200 m) beneath the study site near Estevan, Saskatchewan, Canada. Reservoir monitoring is a crucial component to any geological storage project, and aims to ensure the safe and effective containment of the injected fluids, and evaluate the integrity of the storage and sealing units.An assessment of the ability of DAS VSP&#x27;s to detect the CO2 response has been conducted for the Aquistore site. Prior to injection, fluid flow simulations were performed to predict CO2 distributions in the reservoir. These simulations were used to model the response of the CO2 plume in 2D time-lapse DAS VSP&#x27;s. The expected responses were compared with estimates of time-lapse noise computed with field data from the baseline survey, and it was demonstrated that the plume would be visible in the reservoir after 27 kt of injection.After 36 kt of CO2 injection, the first monitor dataset was acquired. 4D VSP processing and imaging were applied to produce time-lapse difference volumes of the reservoir. Acceptable repeatability was attained, with normalized root-mean-square (nRMS) values less than 0.4 beneath the observation and injection wells. An anomaly in the lower part of the reservoir near the observation and injection wells was attributed to the replacement of brine with CO2.Updated fluid flow simulations were obtained that better replicated the injection parameters observed at the study site. Forward seismic modeling was then performed for 36 kt and 97 kt injection scenarios that reflected the 3D shot and receiver geometry in the field acquisitions. These data were processed using the same sequence applied to the field data to obtain comparable time-lapse difference volumes. Comparisons between the field and synthetic 36 kt anomalies were used to refine interpretations of the CO2 distribution in the reservoir. However, they also revealed the need to update the geological model to better reproduce the laterally asymmetric plume expansion.","abstract_has_math":false,"creators":["Harris, Kyle D."],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Earth Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T07:08:56Z","subjects":["Geophysics","Environmental sciences"],"languages":["en"],"rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-12677"],"render_values":[{"text":"10.22215/etd/2018-12677","href":"https://doi.org/10.22215/etd/2018-12677","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/39965","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/39965","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F39965","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Harris, Kyle D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:51:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:51:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Earth Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Geophysics","Environmental sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-12677"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/39965"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Distributed acoustic sensing (DAS) is a rapidly developing technology that employs optical fibers to detect acoustic disturbances in the subsurface. The Aquistore CO2 storage project uses time-lapse DAS VSP's to monitor injected CO2 in a deep geological reservoir (>3200 m) beneath the study site near Estevan, Saskatchewan, Canada. Reservoir monitoring is a crucial component to any geological storage project, and aims to ensure the safe and effective containment of the injected fluids, and evaluate the integrity of the storage and sealing units.An assessment of the ability of DAS VSP's to detect the CO2 response has been conducted for the Aquistore site. Prior to injection, fluid flow simulations were performed to predict CO2 distributions in the reservoir. These simulations were used to model the response of the CO2 plume in 2D time-lapse DAS VSP's. The expected responses were compared with estimates of time-lapse noise computed with field data from the baseline survey, and it was demonstrated that the plume would be visible in the reservoir after 27 kt of injection.After 36 kt of CO2 injection, the first monitor dataset was acquired. 4D VSP processing and imaging were applied to produce time-lapse difference volumes of the reservoir. Acceptable repeatability was attained, with normalized root-mean-square (nRMS) values less than 0.4 beneath the observation and injection wells. An anomaly in the lower part of the reservoir near the observation and injection wells was attributed to the replacement of brine with CO2.Updated fluid flow simulations were obtained that better replicated the injection parameters observed at the study site. Forward seismic modeling was then performed for 36 kt and 97 kt injection scenarios that reflected the 3D shot and receiver geometry in the field acquisitions. These data were processed using the same sequence applied to the field data to obtain comparable time-lapse difference volumes. Comparisons between the field and synthetic 36 kt anomalies were used to refine interpretations of the CO2 distribution in the reservoir. However, they also revealed the need to update the geological model to better reproduce the laterally asymmetric plume expansion."]},{"key":"dc:title","label":"Title","values":["The Use of Distributed Acoustic Sensing for 4D Monitoring Using Vertical Seismic Profiles: Results from the Aquistore CO2 Storage Project"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Harris, Kyle D."],"dc:date.accessioned":["2025-04-08T19:51:37Z"],"dc:date.available":["2025-04-08T19:51:37Z"],"dc:date.issued":["2018"],"dc:description.abstract":["Distributed acoustic sensing (DAS) is a rapidly developing technology that employs optical fibers to detect acoustic disturbances in the subsurface. The Aquistore CO2 storage project uses time-lapse DAS VSP's to monitor injected CO2 in a deep geological reservoir (>3200 m) beneath the study site near Estevan, Saskatchewan, Canada. Reservoir monitoring is a crucial component to any geological storage project, and aims to ensure the safe and effective containment of the injected fluids, and evaluate the integrity of the storage and sealing units.An assessment of the ability of DAS VSP's to detect the CO2 response has been conducted for the Aquistore site. Prior to injection, fluid flow simulations were performed to predict CO2 distributions in the reservoir. These simulations were used to model the response of the CO2 plume in 2D time-lapse DAS VSP's. The expected responses were compared with estimates of time-lapse noise computed with field data from the baseline survey, and it was demonstrated that the plume would be visible in the reservoir after 27 kt of injection.After 36 kt of CO2 injection, the first monitor dataset was acquired. 4D VSP processing and imaging were applied to produce time-lapse difference volumes of the reservoir. Acceptable repeatability was attained, with normalized root-mean-square (nRMS) values less than 0.4 beneath the observation and injection wells. An anomaly in the lower part of the reservoir near the observation and injection wells was attributed to the replacement of brine with CO2.Updated fluid flow simulations were obtained that better replicated the injection parameters observed at the study site. Forward seismic modeling was then performed for 36 kt and 97 kt injection scenarios that reflected the 3D shot and receiver geometry in the field acquisitions. These data were processed using the same sequence applied to the field data to obtain comparable time-lapse difference volumes. Comparisons between the field and synthetic 36 kt anomalies were used to refine interpretations of the CO2 distribution in the reservoir. However, they also revealed the need to update the geological model to better reproduce the laterally asymmetric plume expansion."],"dc:identifier.doi":["10.22215/etd/2018-12677"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/39965"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Geophysics","Environmental sciences"],"dc:title":["The Use of Distributed Acoustic Sensing for 4D Monitoring Using Vertical Seismic Profiles: Results from the Aquistore CO2 Storage Project"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Earth Sciences"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T07:08:56Z"}