{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40009"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40009","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Evaluation of the Signal Quality of Wrist-Based Photoplethysmography","abstract":"Detection of paroxysmal atrial fibrillation requires continuous cardiovascular monitoring due to its episodic nature. Such monitoring is impractical with electrocardiogram Holter monitors, which are the currently employed for ambulatory cardiovascular monitoring, but are cumbersome for prolonged use. This thesis studies monitoring using photoplethysmography (PPG) devices, which may be embedded into wristband devices which can be easily worn continuously. However, the quality of wrist-based PPG is highly variable, and is subject to artifacts from motion and other interferences. The goal of this thesis is to evaluate the signal quality obtained from wrist-based PPG when used in an ambulatory setting. Ambulatory data is collected over a 24-hour period for 10 elderly, and 16 non-elderly participants. Visual assessment is used as the gold standard for PPG signal quality, with Fleiss's Kappa being used to evaluate the agreement between raters. With this gold standard, 5 classifiers are evaluated using a modified 13-fold cross-validation approach.","abstract_html":"Detection of paroxysmal atrial fibrillation requires continuous cardiovascular monitoring due to its episodic nature. Such monitoring is impractical with electrocardiogram Holter monitors, which are the currently employed for ambulatory cardiovascular monitoring, but are cumbersome for prolonged use. This thesis studies monitoring using photoplethysmography (PPG) devices, which may be embedded into wristband devices which can be easily worn continuously. However, the quality of wrist-based PPG is highly variable, and is subject to artifacts from motion and other interferences. The goal of this thesis is to evaluate the signal quality obtained from wrist-based PPG when used in an ambulatory setting. Ambulatory data is collected over a 24-hour period for 10 elderly, and 16 non-elderly participants. Visual assessment is used as the gold standard for PPG signal quality, with Fleiss&#x27;s Kappa being used to evaluate the agreement between raters. With this gold standard, 5 classifiers are evaluated using a modified 13-fold cross-validation approach.","abstract_has_math":false,"creators":["Pradhan, Nikhilesh"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T07:12:22Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40009"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/40009","href":"https://hdl.handle.net/20.500.14718/40009","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2018-12624","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2018-12624","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F40009","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40009","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pradhan, Nikhilesh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:52:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:52:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2018-12624"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40009"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Detection of paroxysmal atrial fibrillation requires continuous cardiovascular monitoring due to its episodic nature. Such monitoring is impractical with electrocardiogram Holter monitors, which are the currently employed for ambulatory cardiovascular monitoring, but are cumbersome for prolonged use. This thesis studies monitoring using photoplethysmography (PPG) devices, which may be embedded into wristband devices which can be easily worn continuously. However, the quality of wrist-based PPG is highly variable, and is subject to artifacts from motion and other interferences. The goal of this thesis is to evaluate the signal quality obtained from wrist-based PPG when used in an ambulatory setting. Ambulatory data is collected over a 24-hour period for 10 elderly, and 16 non-elderly participants. Visual assessment is used as the gold standard for PPG signal quality, with Fleiss's Kappa being used to evaluate the agreement between raters. With this gold standard, 5 classifiers are evaluated using a modified 13-fold cross-validation approach."]},{"key":"dc:title","label":"Title","values":["Evaluation of the Signal Quality of Wrist-Based Photoplethysmography"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Pradhan, Nikhilesh"],"dc:date.accessioned":["2025-04-08T19:52:29Z"],"dc:date.available":["2025-04-08T19:52:29Z"],"dc:date.issued":["2018"],"dc:description.abstract":["Detection of paroxysmal atrial fibrillation requires continuous cardiovascular monitoring due to its episodic nature. Such monitoring is impractical with electrocardiogram Holter monitors, which are the currently employed for ambulatory cardiovascular monitoring, but are cumbersome for prolonged use. This thesis studies monitoring using photoplethysmography (PPG) devices, which may be embedded into wristband devices which can be easily worn continuously. However, the quality of wrist-based PPG is highly variable, and is subject to artifacts from motion and other interferences. The goal of this thesis is to evaluate the signal quality obtained from wrist-based PPG when used in an ambulatory setting. Ambulatory data is collected over a 24-hour period for 10 elderly, and 16 non-elderly participants. Visual assessment is used as the gold standard for PPG signal quality, with Fleiss's Kappa being used to evaluate the agreement between raters. With this gold standard, 5 classifiers are evaluated using a modified 13-fold cross-validation approach."],"dc:identifier.doi":["10.22215/etd/2018-12624"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40009"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["Evaluation of the Signal Quality of Wrist-Based Photoplethysmography"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:12:22Z"}