{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40215"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40215","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Thermal Evaluation of Vacuum Insulation Panels Within Residential Building Envelopes","abstract":"In Canada, heating and cooling in buildings accounts for 16.5% of the total secondary end energy use in the residential sector. Improvements in the building enclosure can reduce the energy required to maintain the interior conditions through additional insulation. The thesis analyzes the effects of vacuum insulation panels (VIPs) within a residential building envelope. The VIPs were evaluated using a guarded hot-box at steady-state conditions. Paneling and encasing techniques were performed in the guarded hot-box to quantify the change in performance between the panel center and edges. The VIP thermal performance showed a 36% decay in performance at the edge, when compared to the center, proving the materials acts non-homogenous within the building envelope. The results indicate that VIPs encased in insulation offer high performance and minimize the risk of puncture. Also, a single profile simulation can provide reliable results of a wall assembly containing multiple non-homogenous layers.","abstract_html":"In Canada, heating and cooling in buildings accounts for 16.5% of the total secondary end energy use in the residential sector. Improvements in the building enclosure can reduce the energy required to maintain the interior conditions through additional insulation. The thesis analyzes the effects of vacuum insulation panels (VIPs) within a residential building envelope. The VIPs were evaluated using a guarded hot-box at steady-state conditions. Paneling and encasing techniques were performed in the guarded hot-box to quantify the change in performance between the panel center and edges. The VIP thermal performance showed a 36% decay in performance at the edge, when compared to the center, proving the materials acts non-homogenous within the building envelope. The results indicate that VIPs encased in insulation offer high performance and minimize the risk of puncture. Also, a single profile simulation can provide reliable results of a wall assembly containing multiple non-homogenous layers.","abstract_has_math":false,"creators":["Conley, Brock Paul"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T06:54:02Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2017-11946"],"render_values":[{"text":"10.22215/etd/2017-11946","href":"https://doi.org/10.22215/etd/2017-11946","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40215","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40215","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40215","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Conley, Brock Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:56:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:56:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2017-11946"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40215"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In Canada, heating and cooling in buildings accounts for 16.5% of the total secondary end energy use in the residential sector. Improvements in the building enclosure can reduce the energy required to maintain the interior conditions through additional insulation. The thesis analyzes the effects of vacuum insulation panels (VIPs) within a residential building envelope. The VIPs were evaluated using a guarded hot-box at steady-state conditions. Paneling and encasing techniques were performed in the guarded hot-box to quantify the change in performance between the panel center and edges. The VIP thermal performance showed a 36% decay in performance at the edge, when compared to the center, proving the materials acts non-homogenous within the building envelope. The results indicate that VIPs encased in insulation offer high performance and minimize the risk of puncture. Also, a single profile simulation can provide reliable results of a wall assembly containing multiple non-homogenous layers."]},{"key":"dc:title","label":"Title","values":["Thermal Evaluation of Vacuum Insulation Panels Within Residential Building Envelopes"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Conley, Brock Paul"],"dc:date.accessioned":["2025-04-08T19:56:19Z"],"dc:date.available":["2025-04-08T19:56:19Z"],"dc:date.issued":["2017"],"dc:description.abstract":["In Canada, heating and cooling in buildings accounts for 16.5% of the total secondary end energy use in the residential sector. Improvements in the building enclosure can reduce the energy required to maintain the interior conditions through additional insulation. The thesis analyzes the effects of vacuum insulation panels (VIPs) within a residential building envelope. The VIPs were evaluated using a guarded hot-box at steady-state conditions. Paneling and encasing techniques were performed in the guarded hot-box to quantify the change in performance between the panel center and edges. The VIP thermal performance showed a 36% decay in performance at the edge, when compared to the center, proving the materials acts non-homogenous within the building envelope. The results indicate that VIPs encased in insulation offer high performance and minimize the risk of puncture. Also, a single profile simulation can provide reliable results of a wall assembly containing multiple non-homogenous layers."],"dc:identifier.doi":["10.22215/etd/2017-11946"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40215"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Thermal Evaluation of Vacuum Insulation Panels Within Residential Building Envelopes"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:54:02Z"}