{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40260"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40260","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Performance Analysis and Modeling of a Printed Circuit Heat Exchanger with Air and Carbon Dioxide as Working Fluids","abstract":"A Printed Circuit Heat Exchanger (PCHE) was tested using air and carbon dioxide as working fluids. These tests are conducted and analyzed to pave way for testing the heat exchanger with supercritical carbon dioxide (S-CO2), to obtain data on its performance for use in S-CO2 Brayton cycles. The tests have been conducted at steady state with a total of 18 data sets. Air inlet temperature has been varied from 70C to 140C. The pressures for CO2 and air were varied from 5 to 10 bars while varying the flow from 5 to 10 LPM. A 3D COMSOL model has been created to simulate the PCHE's performance and the results obtained from the simulations have been compared to the results obtained experimentally. The results show an average percentage error of 5.65% when comparing the outlet temperatures of air and an average of 5.73% error when comparing the outlet temperatures of CO2.","abstract_html":"A Printed Circuit Heat Exchanger (PCHE) was tested using air and carbon dioxide as working fluids. These tests are conducted and analyzed to pave way for testing the heat exchanger with supercritical carbon dioxide (S-CO2), to obtain data on its performance for use in S-CO2 Brayton cycles. The tests have been conducted at steady state with a total of 18 data sets. Air inlet temperature has been varied from 70C to 140C. The pressures for CO2 and air were varied from 5 to 10 bars while varying the flow from 5 to 10 LPM. A 3D COMSOL model has been created to simulate the PCHE&#x27;s performance and the results obtained from the simulations have been compared to the results obtained experimentally. The results show an average percentage error of 5.65% when comparing the outlet temperatures of air and an average of 5.73% error when comparing the outlet temperatures of CO2.","abstract_has_math":false,"creators":["Daouk, Amr"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T07:11:29Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2017-11804"],"render_values":[{"text":"10.22215/etd/2017-11804","href":"https://doi.org/10.22215/etd/2017-11804","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40260","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40260","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40260","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Daouk, Amr"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T19:57:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T19:57:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2017-11804"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40260"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A Printed Circuit Heat Exchanger (PCHE) was tested using air and carbon dioxide as working fluids. These tests are conducted and analyzed to pave way for testing the heat exchanger with supercritical carbon dioxide (S-CO2), to obtain data on its performance for use in S-CO2 Brayton cycles. The tests have been conducted at steady state with a total of 18 data sets. Air inlet temperature has been varied from 70C to 140C. The pressures for CO2 and air were varied from 5 to 10 bars while varying the flow from 5 to 10 LPM. A 3D COMSOL model has been created to simulate the PCHE's performance and the results obtained from the simulations have been compared to the results obtained experimentally. The results show an average percentage error of 5.65% when comparing the outlet temperatures of air and an average of 5.73% error when comparing the outlet temperatures of CO2."]},{"key":"dc:title","label":"Title","values":["Performance Analysis and Modeling of a Printed Circuit Heat Exchanger with Air and Carbon Dioxide as Working Fluids"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Daouk, Amr"],"dc:date.accessioned":["2025-04-08T19:57:15Z"],"dc:date.available":["2025-04-08T19:57:15Z"],"dc:date.issued":["2017"],"dc:description.abstract":["A Printed Circuit Heat Exchanger (PCHE) was tested using air and carbon dioxide as working fluids. These tests are conducted and analyzed to pave way for testing the heat exchanger with supercritical carbon dioxide (S-CO2), to obtain data on its performance for use in S-CO2 Brayton cycles. The tests have been conducted at steady state with a total of 18 data sets. Air inlet temperature has been varied from 70C to 140C. The pressures for CO2 and air were varied from 5 to 10 bars while varying the flow from 5 to 10 LPM. A 3D COMSOL model has been created to simulate the PCHE's performance and the results obtained from the simulations have been compared to the results obtained experimentally. The results show an average percentage error of 5.65% when comparing the outlet temperatures of air and an average of 5.73% error when comparing the outlet temperatures of CO2."],"dc:identifier.doi":["10.22215/etd/2017-11804"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40260"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2017 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["Performance Analysis and Modeling of a Printed Circuit Heat Exchanger with Air and Carbon Dioxide as Working Fluids"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:11:29Z"}