{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40529"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40529","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Dynamic Model-Based Dose Calculations of Permanent Implant Prostate Brachytherapy","abstract":"This thesis presents the development of a framework for performing dynamic model-based dose calculations in target organs exhibiting geometry changes during permanent implant brachytherapy. The framework is applied to investigate the dosimetric effect of edema during125I prostate brachytherapy. Dynamic dose distributions are accumulated from mapped dose distributions calculated using Monte Carlo (MC) simulations on treatment geometries predicted from post-implant images and clinically-observed models of edema. Ten unique edema resolution models are implemented for 120 patients. Clinical AAPM TG-43 and static MC dose calculations overestimate D90 values compared to dynamically-calculated dose distributions; these overestimations range from 5 to >30% depending on edema model and patient parameters,e.g., the presence of intraprostatic calcifications. Edema should be considered for accurate dose calculations of permanent implant prostate brachytherapy treatments.","abstract_html":"This thesis presents the development of a framework for performing dynamic model-based dose calculations in target organs exhibiting geometry changes during permanent implant brachytherapy. The framework is applied to investigate the dosimetric effect of edema during125I prostate brachytherapy. Dynamic dose distributions are accumulated from mapped dose distributions calculated using Monte Carlo (MC) simulations on treatment geometries predicted from post-implant images and clinically-observed models of edema. Ten unique edema resolution models are implemented for 120 patients. Clinical AAPM TG-43 and static MC dose calculations overestimate D90 values compared to dynamically-calculated dose distributions; these overestimations range from 5 to &gt;30% depending on edema model and patient parameters,e.g., the presence of intraprostatic calcifications. Edema should be considered for accurate dose calculations of permanent implant prostate brachytherapy treatments.","abstract_has_math":false,"creators":["McCooeye, Luke Pollard"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T07:09:57Z","subjects":["Physics","Radiation"],"languages":["en"],"rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13820"],"render_values":[{"text":"10.22215/etd/2019-13820","href":"https://doi.org/10.22215/etd/2019-13820","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40529","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40529","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40529","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["McCooeye, Luke Pollard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:01:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:01:59Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics","Radiation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13820"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40529"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the development of a framework for performing dynamic model-based dose calculations in target organs exhibiting geometry changes during permanent implant brachytherapy. The framework is applied to investigate the dosimetric effect of edema during125I prostate brachytherapy. Dynamic dose distributions are accumulated from mapped dose distributions calculated using Monte Carlo (MC) simulations on treatment geometries predicted from post-implant images and clinically-observed models of edema. Ten unique edema resolution models are implemented for 120 patients. Clinical AAPM TG-43 and static MC dose calculations overestimate D90 values compared to dynamically-calculated dose distributions; these overestimations range from 5 to >30% depending on edema model and patient parameters,e.g., the presence of intraprostatic calcifications. Edema should be considered for accurate dose calculations of permanent implant prostate brachytherapy treatments."]},{"key":"dc:title","label":"Title","values":["Dynamic Model-Based Dose Calculations of Permanent Implant Prostate Brachytherapy"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["McCooeye, Luke Pollard"],"dc:date.accessioned":["2025-04-08T20:01:59Z"],"dc:date.available":["2025-04-08T20:01:59Z"],"dc:date.issued":["2019"],"dc:description.abstract":["This thesis presents the development of a framework for performing dynamic model-based dose calculations in target organs exhibiting geometry changes during permanent implant brachytherapy. The framework is applied to investigate the dosimetric effect of edema during125I prostate brachytherapy. Dynamic dose distributions are accumulated from mapped dose distributions calculated using Monte Carlo (MC) simulations on treatment geometries predicted from post-implant images and clinically-observed models of edema. Ten unique edema resolution models are implemented for 120 patients. Clinical AAPM TG-43 and static MC dose calculations overestimate D90 values compared to dynamically-calculated dose distributions; these overestimations range from 5 to >30% depending on edema model and patient parameters,e.g., the presence of intraprostatic calcifications. Edema should be considered for accurate dose calculations of permanent implant prostate brachytherapy treatments."],"dc:identifier.doi":["10.22215/etd/2019-13820"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40529"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Physics","Radiation"],"dc:title":["Dynamic Model-Based Dose Calculations of Permanent Implant Prostate Brachytherapy"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:09:57Z"}