{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40683"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40683","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Background Rejection in Two-Phase Xenon using Scintillation Pulse-Shape Discrimination for Neutrinoless Double-Beta Decay Searches","abstract":"This work attempted to identify measurable differences in the pulse shapes of one and two electron scintillation events in liquid xenon, with the goal of developing a technique for improved background rejection in neutrinoless double-beta decay (0νββ) experiments. A system was constructed to generate one and two electron events using gamma rays from an external thorium-228 source. Sodium iodide counters were used to tag one and two electron events, which were produced from Compton scattering and pair-production of the thorium gamma respectively. A novel cryogenic compatible silicon photomultiplier was used to measure the light from scintillation events and it was demonstrated that the system could trigger on coincidence between the scintillation and event tag signals. No conclusions could be made on the timing structure of events, based on long decay times in the photomultiplier and electronics, and suggestions are made for future improvements.","abstract_html":"This work attempted to identify measurable differences in the pulse shapes of one and two electron scintillation events in liquid xenon, with the goal of developing a technique for improved background rejection in neutrinoless double-beta decay (0νββ) experiments. A system was constructed to generate one and two electron events using gamma rays from an external thorium-228 source. Sodium iodide counters were used to tag one and two electron events, which were produced from Compton scattering and pair-production of the thorium gamma respectively. A novel cryogenic compatible silicon photomultiplier was used to measure the light from scintillation events and it was demonstrated that the system could trigger on coincidence between the scintillation and event tag signals. No conclusions could be made on the timing structure of events, based on long decay times in the photomultiplier and electronics, and suggestions are made for future improvements.","abstract_has_math":false,"creators":["Veenstra, Braeden Thomas"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T07:04:20Z","subjects":["Particles (Nuclear physics)"],"languages":["en"],"rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-13917"],"render_values":[{"text":"10.22215/etd/2020-13917","href":"https://doi.org/10.22215/etd/2020-13917","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40683","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40683","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40683","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Veenstra, Braeden Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:04:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:04:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Particles (Nuclear physics)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-13917"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40683"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work attempted to identify measurable differences in the pulse shapes of one and two electron scintillation events in liquid xenon, with the goal of developing a technique for improved background rejection in neutrinoless double-beta decay (0νββ) experiments. A system was constructed to generate one and two electron events using gamma rays from an external thorium-228 source. Sodium iodide counters were used to tag one and two electron events, which were produced from Compton scattering and pair-production of the thorium gamma respectively. A novel cryogenic compatible silicon photomultiplier was used to measure the light from scintillation events and it was demonstrated that the system could trigger on coincidence between the scintillation and event tag signals. No conclusions could be made on the timing structure of events, based on long decay times in the photomultiplier and electronics, and suggestions are made for future improvements."]},{"key":"dc:title","label":"Title","values":["Background Rejection in Two-Phase Xenon using Scintillation Pulse-Shape Discrimination for Neutrinoless Double-Beta Decay Searches"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Veenstra, Braeden Thomas"],"dc:date.accessioned":["2025-04-08T20:04:51Z"],"dc:date.available":["2025-04-08T20:04:51Z"],"dc:date.issued":["2020"],"dc:description.abstract":["This work attempted to identify measurable differences in the pulse shapes of one and two electron scintillation events in liquid xenon, with the goal of developing a technique for improved background rejection in neutrinoless double-beta decay (0νββ) experiments. A system was constructed to generate one and two electron events using gamma rays from an external thorium-228 source. Sodium iodide counters were used to tag one and two electron events, which were produced from Compton scattering and pair-production of the thorium gamma respectively. A novel cryogenic compatible silicon photomultiplier was used to measure the light from scintillation events and it was demonstrated that the system could trigger on coincidence between the scintillation and event tag signals. No conclusions could be made on the timing structure of events, based on long decay times in the photomultiplier and electronics, and suggestions are made for future improvements."],"dc:identifier.doi":["10.22215/etd/2020-13917"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40683"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Particles (Nuclear physics)"],"dc:title":["Background Rejection in Two-Phase Xenon using Scintillation Pulse-Shape Discrimination for Neutrinoless Double-Beta Decay Searches"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:04:20Z"}