{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40710"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40710","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Ozone Chemically-Enhanced Backwashes For Ceramic Membrane Fouling Control in Cyanobacteria-Laden Surface Water Applications","abstract":"Membrane fouling in surface waters impacted by cyanobacteria is poorly controlled and results in high operating costs. A possible solution is the chemically-enhanced backwash (CEB). This research investigates the potential of using an ozone CEB to control the fouling caused by Microcystis aeruginosa in surface water on a ceramic ultrafiltration membrane. Batch ozonation and dead-end, continuous flow, experiments were conducted with ozone doses between 0 and 19 mg O3/mg carbon on the membrane. In the batch tests, ozone reacted more rapidly with the surface water than with cyanobacteria. The opposite was observed during a CEB, highlighting the contribution of the hydraulic force on CEB performance since ozone likely weakens the compressible cake layer formed by cyanobacteria on the membrane surface. Overall, all ozone CEBs were capable of recovering over 80% of the membrane's specific flux whereas only 66% overall was recovered without the use of ozone.","abstract_html":"Membrane fouling in surface waters impacted by cyanobacteria is poorly controlled and results in high operating costs. A possible solution is the chemically-enhanced backwash (CEB). This research investigates the potential of using an ozone CEB to control the fouling caused by Microcystis aeruginosa in surface water on a ceramic ultrafiltration membrane. Batch ozonation and dead-end, continuous flow, experiments were conducted with ozone doses between 0 and 19 mg O3/mg carbon on the membrane. In the batch tests, ozone reacted more rapidly with the surface water than with cyanobacteria. The opposite was observed during a CEB, highlighting the contribution of the hydraulic force on CEB performance since ozone likely weakens the compressible cake layer formed by cyanobacteria on the membrane surface. Overall, all ozone CEBs were capable of recovering over 80% of the membrane&#x27;s specific flux whereas only 66% overall was recovered without the use of ozone.","abstract_has_math":false,"creators":["Venne, Stephane Pierre"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T06:57:23Z","subjects":["Environmental sciences"],"languages":["en"],"rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-13962"],"render_values":[{"text":"10.22215/etd/2020-13962","href":"https://doi.org/10.22215/etd/2020-13962","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40710","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40710","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40710","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Onita Basu (Co-author)"]},{"key":"dc:creator","label":"Author","values":["Venne, Stephane Pierre"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:05:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:05:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Environmental sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-13962"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40710"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Membrane fouling in surface waters impacted by cyanobacteria is poorly controlled and results in high operating costs. A possible solution is the chemically-enhanced backwash (CEB). This research investigates the potential of using an ozone CEB to control the fouling caused by Microcystis aeruginosa in surface water on a ceramic ultrafiltration membrane. Batch ozonation and dead-end, continuous flow, experiments were conducted with ozone doses between 0 and 19 mg O3/mg carbon on the membrane. In the batch tests, ozone reacted more rapidly with the surface water than with cyanobacteria. The opposite was observed during a CEB, highlighting the contribution of the hydraulic force on CEB performance since ozone likely weakens the compressible cake layer formed by cyanobacteria on the membrane surface. Overall, all ozone CEBs were capable of recovering over 80% of the membrane's specific flux whereas only 66% overall was recovered without the use of ozone."]},{"key":"dc:title","label":"Title","values":["Ozone Chemically-Enhanced Backwashes For Ceramic Membrane Fouling Control in Cyanobacteria-Laden Surface Water Applications"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.other":["Onita Basu (Co-author)"],"dc:creator":["Venne, Stephane Pierre"],"dc:date.accessioned":["2025-04-08T20:05:17Z"],"dc:date.available":["2025-04-08T20:05:17Z"],"dc:date.issued":["2020"],"dc:description.abstract":["Membrane fouling in surface waters impacted by cyanobacteria is poorly controlled and results in high operating costs. A possible solution is the chemically-enhanced backwash (CEB). This research investigates the potential of using an ozone CEB to control the fouling caused by Microcystis aeruginosa in surface water on a ceramic ultrafiltration membrane. Batch ozonation and dead-end, continuous flow, experiments were conducted with ozone doses between 0 and 19 mg O3/mg carbon on the membrane. In the batch tests, ozone reacted more rapidly with the surface water than with cyanobacteria. The opposite was observed during a CEB, highlighting the contribution of the hydraulic force on CEB performance since ozone likely weakens the compressible cake layer formed by cyanobacteria on the membrane surface. Overall, all ozone CEBs were capable of recovering over 80% of the membrane's specific flux whereas only 66% overall was recovered without the use of ozone."],"dc:identifier.doi":["10.22215/etd/2020-13962"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40710"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Environmental sciences"],"dc:title":["Ozone Chemically-Enhanced Backwashes For Ceramic Membrane Fouling Control in Cyanobacteria-Laden Surface Water Applications"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:57:23Z"}