{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40794"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40794","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Leg Scanner for Detection and Tracking of Evolving Pigmented Skin Lesions for Melanoma Cancer Prevention","abstract":"Melanoma is an aggressive skin cancer prevalent among the Caucasian population. The site of melanoma is gender dependent: for women the prevalent site is the legs. Success of the treatment strongly correlates with early dysplastic nevus excision. Diagnosis relies on full-body skin examination and baseline photography to locate evolving, and therefore suspicious, moles.We designed the first semi-automated legs scanner which uses one camera and laser range finder to capture images and measurements respectively. The scanner circulates around the leg, along its full length. From the collected data, a 3D leg model with moles is created. The moles are registered over temporal scans for comparison and detection of moles' evolution.Our algorithm was tested on simulated leg model that changes over time. The average accuracy of mole registration from two temporal scans at optimal scanner settings was 94.87% with standard deviation of 6.10.","abstract_html":"Melanoma is an aggressive skin cancer prevalent among the Caucasian population. The site of melanoma is gender dependent: for women the prevalent site is the legs. Success of the treatment strongly correlates with early dysplastic nevus excision. Diagnosis relies on full-body skin examination and baseline photography to locate evolving, and therefore suspicious, moles.We designed the first semi-automated legs scanner which uses one camera and laser range finder to capture images and measurements respectively. The scanner circulates around the leg, along its full length. From the collected data, a 3D leg model with moles is created. The moles are registered over temporal scans for comparison and detection of moles&#x27; evolution.Our algorithm was tested on simulated leg model that changes over time. The average accuracy of mole registration from two temporal scans at optimal scanner settings was 94.87% with standard deviation of 6.10.","abstract_has_math":false,"creators":["Bondarev, Alisa"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T06:54:43Z","subjects":["Biomedical engineering","Computer science"],"languages":["en"],"rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13624"],"render_values":[{"text":"10.22215/etd/2019-13624","href":"https://doi.org/10.22215/etd/2019-13624","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40794","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40794","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40794","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bondarev, Alisa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:06:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:06:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering","Computer science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13624"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40794"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Melanoma is an aggressive skin cancer prevalent among the Caucasian population. The site of melanoma is gender dependent: for women the prevalent site is the legs. Success of the treatment strongly correlates with early dysplastic nevus excision. Diagnosis relies on full-body skin examination and baseline photography to locate evolving, and therefore suspicious, moles.We designed the first semi-automated legs scanner which uses one camera and laser range finder to capture images and measurements respectively. The scanner circulates around the leg, along its full length. From the collected data, a 3D leg model with moles is created. The moles are registered over temporal scans for comparison and detection of moles' evolution.Our algorithm was tested on simulated leg model that changes over time. The average accuracy of mole registration from two temporal scans at optimal scanner settings was 94.87% with standard deviation of 6.10."]},{"key":"dc:title","label":"Title","values":["Leg Scanner for Detection and Tracking of Evolving Pigmented Skin Lesions for Melanoma Cancer Prevention"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Bondarev, Alisa"],"dc:date.accessioned":["2025-04-08T20:06:57Z"],"dc:date.available":["2025-04-08T20:06:57Z"],"dc:date.issued":["2019"],"dc:description.abstract":["Melanoma is an aggressive skin cancer prevalent among the Caucasian population. The site of melanoma is gender dependent: for women the prevalent site is the legs. Success of the treatment strongly correlates with early dysplastic nevus excision. Diagnosis relies on full-body skin examination and baseline photography to locate evolving, and therefore suspicious, moles.We designed the first semi-automated legs scanner which uses one camera and laser range finder to capture images and measurements respectively. The scanner circulates around the leg, along its full length. From the collected data, a 3D leg model with moles is created. The moles are registered over temporal scans for comparison and detection of moles' evolution.Our algorithm was tested on simulated leg model that changes over time. The average accuracy of mole registration from two temporal scans at optimal scanner settings was 94.87% with standard deviation of 6.10."],"dc:identifier.doi":["10.22215/etd/2019-13624"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40794"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering","Computer science"],"dc:title":["Leg Scanner for Detection and Tracking of Evolving Pigmented Skin Lesions for Melanoma Cancer Prevention"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:54:43Z"}