{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40819"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40819","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Exploring Applicability of Direct Analysis in Real Time with Mass Spectrometry (DART-MS) to Identify Homemade Explosive Residues Post-Blast","abstract":"Application of Direct-Analysis-in-Real-Time (DART) ionization with mass spectrometry (DART-MS) to identify explosives from post-blast residues is presented. Explosives studied represent current threats encountered in criminal investigations: homemade organic peroxides, binary explosives and smokeless powder. Simulated improvised explosive devices (IEDs) were manufactured using triacetone triperoxide (TATP), hexamethylene triperoxide diamine (HMTD), methylethyl ketone peroxide (MEKP), homemade binary explosives (composed of a fuel-oxidizer) and smokeless powders. Each IED yielded bomb fragments representative of actual materials recovered from bombing investigations. Smokeless powder was of interest no reported method to identify nitrocellulose (NC) post-blast exists. This study aimed to demonstrate application of DART-MS for identification of homemade explosives using real-world samples and to characterize thermal breakdown products of NC. Recovered fragments were analyzed directly and in-directly using full scan high-resolution mass spectrometry (HRMS). This work demonstrates the forensic validity of DART-MS to provide rapid and quality-assured identification of explosive residues from real post-blast IED fragments.","abstract_html":"Application of Direct-Analysis-in-Real-Time (DART) ionization with mass spectrometry (DART-MS) to identify explosives from post-blast residues is presented. Explosives studied represent current threats encountered in criminal investigations: homemade organic peroxides, binary explosives and smokeless powder. Simulated improvised explosive devices (IEDs) were manufactured using triacetone triperoxide (TATP), hexamethylene triperoxide diamine (HMTD), methylethyl ketone peroxide (MEKP), homemade binary explosives (composed of a fuel-oxidizer) and smokeless powders. Each IED yielded bomb fragments representative of actual materials recovered from bombing investigations. Smokeless powder was of interest no reported method to identify nitrocellulose (NC) post-blast exists. This study aimed to demonstrate application of DART-MS for identification of homemade explosives using real-world samples and to characterize thermal breakdown products of NC. Recovered fragments were analyzed directly and in-directly using full scan high-resolution mass spectrometry (HRMS). This work demonstrates the forensic validity of DART-MS to provide rapid and quality-assured identification of explosive residues from real post-blast IED fragments.","abstract_has_math":false,"creators":["Black, Chelsea Elizabeth"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T07:04:26Z","subjects":["Analytical chemistry"],"languages":["en"],"rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13644"],"render_values":[{"text":"10.22215/etd/2019-13644","href":"https://doi.org/10.22215/etd/2019-13644","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40819","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40819","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40819","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Black, Chelsea Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:07:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:07:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Analytical chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13644"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40819"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Application of Direct-Analysis-in-Real-Time (DART) ionization with mass spectrometry (DART-MS) to identify explosives from post-blast residues is presented. Explosives studied represent current threats encountered in criminal investigations: homemade organic peroxides, binary explosives and smokeless powder. Simulated improvised explosive devices (IEDs) were manufactured using triacetone triperoxide (TATP), hexamethylene triperoxide diamine (HMTD), methylethyl ketone peroxide (MEKP), homemade binary explosives (composed of a fuel-oxidizer) and smokeless powders. Each IED yielded bomb fragments representative of actual materials recovered from bombing investigations. Smokeless powder was of interest no reported method to identify nitrocellulose (NC) post-blast exists. This study aimed to demonstrate application of DART-MS for identification of homemade explosives using real-world samples and to characterize thermal breakdown products of NC. Recovered fragments were analyzed directly and in-directly using full scan high-resolution mass spectrometry (HRMS). This work demonstrates the forensic validity of DART-MS to provide rapid and quality-assured identification of explosive residues from real post-blast IED fragments."]},{"key":"dc:title","label":"Title","values":["Exploring Applicability of Direct Analysis in Real Time with Mass Spectrometry (DART-MS) to Identify Homemade Explosive Residues Post-Blast"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Black, Chelsea Elizabeth"],"dc:date.accessioned":["2025-04-08T20:07:29Z"],"dc:date.available":["2025-04-08T20:07:29Z"],"dc:date.issued":["2019"],"dc:description.abstract":["Application of Direct-Analysis-in-Real-Time (DART) ionization with mass spectrometry (DART-MS) to identify explosives from post-blast residues is presented. Explosives studied represent current threats encountered in criminal investigations: homemade organic peroxides, binary explosives and smokeless powder. Simulated improvised explosive devices (IEDs) were manufactured using triacetone triperoxide (TATP), hexamethylene triperoxide diamine (HMTD), methylethyl ketone peroxide (MEKP), homemade binary explosives (composed of a fuel-oxidizer) and smokeless powders. Each IED yielded bomb fragments representative of actual materials recovered from bombing investigations. Smokeless powder was of interest no reported method to identify nitrocellulose (NC) post-blast exists. This study aimed to demonstrate application of DART-MS for identification of homemade explosives using real-world samples and to characterize thermal breakdown products of NC. Recovered fragments were analyzed directly and in-directly using full scan high-resolution mass spectrometry (HRMS). This work demonstrates the forensic validity of DART-MS to provide rapid and quality-assured identification of explosive residues from real post-blast IED fragments."],"dc:identifier.doi":["10.22215/etd/2019-13644"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40819"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Analytical chemistry"],"dc:title":["Exploring Applicability of Direct Analysis in Real Time with Mass Spectrometry (DART-MS) to Identify Homemade Explosive Residues Post-Blast"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:04:26Z"}