{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40833"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40833","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Radiobiological modeling of Pd-103 permanent breast seed implant brachytherapy using Monte Carlo dose calculations","abstract":"Monte Carlo (MC) based dose calculations derived from real patient data are coupled to advanced radiobiological models to assess their sensitivity as well as the effectiveness of Pd-103 permanent breast seed implant brachytherapy (PBSI) treatments. Dose distributions are obtained following both the standard TG43 protocol and using realistic tissue models as recommended by TG186. Discrepancies in dose are investigated and TG43 results show consistent overestimations in dose metrics within the target volume when compared to the TG186 models, as well as an underestimation of the dose distributed to most normal tissues. The inconsistencies are investigated further by exploring the possible effects these have on the assessment of tumour control probabilities (TCP) and normal tissue complication probabilities (NTCP) using various sets of radiobiological parameters. The work presents evidence supporting a shift in focus from the standard TG43 water-based models towards realistic patient models for radiobiological modeling of low dose rate PBSI.","abstract_html":"Monte Carlo (MC) based dose calculations derived from real patient data are coupled to advanced radiobiological models to assess their sensitivity as well as the effectiveness of Pd-103 permanent breast seed implant brachytherapy (PBSI) treatments. Dose distributions are obtained following both the standard TG43 protocol and using realistic tissue models as recommended by TG186. Discrepancies in dose are investigated and TG43 results show consistent overestimations in dose metrics within the target volume when compared to the TG186 models, as well as an underestimation of the dose distributed to most normal tissues. The inconsistencies are investigated further by exploring the possible effects these have on the assessment of tumour control probabilities (TCP) and normal tissue complication probabilities (NTCP) using various sets of radiobiological parameters. The work presents evidence supporting a shift in focus from the standard TG43 water-based models towards realistic patient models for radiobiological modeling of low dose rate PBSI.","abstract_has_math":false,"creators":["Thibodeau, Michael Edward"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T06:59:17Z","subjects":["Radiation","Medical physics","Physics","Oncology"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15613"],"render_values":[{"text":"10.22215/etd/2023-15613","href":"https://doi.org/10.22215/etd/2023-15613","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40833","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40833","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40833","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Thibodeau, Michael Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:07:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:07:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Radiation","Medical physics","Physics","Oncology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15613"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40833"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Monte Carlo (MC) based dose calculations derived from real patient data are coupled to advanced radiobiological models to assess their sensitivity as well as the effectiveness of Pd-103 permanent breast seed implant brachytherapy (PBSI) treatments. Dose distributions are obtained following both the standard TG43 protocol and using realistic tissue models as recommended by TG186. Discrepancies in dose are investigated and TG43 results show consistent overestimations in dose metrics within the target volume when compared to the TG186 models, as well as an underestimation of the dose distributed to most normal tissues. The inconsistencies are investigated further by exploring the possible effects these have on the assessment of tumour control probabilities (TCP) and normal tissue complication probabilities (NTCP) using various sets of radiobiological parameters. The work presents evidence supporting a shift in focus from the standard TG43 water-based models towards realistic patient models for radiobiological modeling of low dose rate PBSI."]},{"key":"dc:title","label":"Title","values":["Radiobiological modeling of Pd-103 permanent breast seed implant brachytherapy using Monte Carlo dose calculations"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Thibodeau, Michael Edward"],"dc:date.accessioned":["2025-04-08T20:07:48Z"],"dc:date.available":["2025-04-08T20:07:48Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Monte Carlo (MC) based dose calculations derived from real patient data are coupled to advanced radiobiological models to assess their sensitivity as well as the effectiveness of Pd-103 permanent breast seed implant brachytherapy (PBSI) treatments. Dose distributions are obtained following both the standard TG43 protocol and using realistic tissue models as recommended by TG186. Discrepancies in dose are investigated and TG43 results show consistent overestimations in dose metrics within the target volume when compared to the TG186 models, as well as an underestimation of the dose distributed to most normal tissues. The inconsistencies are investigated further by exploring the possible effects these have on the assessment of tumour control probabilities (TCP) and normal tissue complication probabilities (NTCP) using various sets of radiobiological parameters. The work presents evidence supporting a shift in focus from the standard TG43 water-based models towards realistic patient models for radiobiological modeling of low dose rate PBSI."],"dc:identifier.doi":["10.22215/etd/2023-15613"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40833"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Radiation","Medical physics","Physics","Oncology"],"dc:title":["Radiobiological modeling of Pd-103 permanent breast seed implant brachytherapy using Monte Carlo dose calculations"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T06:59:17Z"}