{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/40862"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/40862","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Argon Calibration of a Cryogenic Distillation Column for Xenon Isotopic Enrichment","abstract":"This work presents the calibration for a 14.6 m-high cryogenic distillation column which is performed using argon. This column is located at SNOLAB, an underground lab in Canada, and it is planned to study the potential of using distillation for xenon isotopic enrichment. Our study yields a measurement of the still’s height equivalent to theoretical plate (HETP) of 4.29±0.13 cm, consistent with a previous study using the same packing material. A new approach introduced in this analysis achieves a smaller error for this HETP compared to the previous study. Our HETP value will be used in the measurement of the vapour pressure isotopic effect of xenon in the future. In addition, we provide a measurement for the fractionation factor ln(α38−40) = (2.731± 0.017)×10−3 at the nominal boiling point, which has improved error and is consistent with theoretical values.","abstract_html":"This work presents the calibration for a 14.6 m-high cryogenic distillation column which is performed using argon. This column is located at SNOLAB, an underground lab in Canada, and it is planned to study the potential of using distillation for xenon isotopic enrichment. Our study yields a measurement of the still’s height equivalent to theoretical plate (HETP) of 4.29±0.13 cm, consistent with a previous study using the same packing material. A new approach introduced in this analysis achieves a smaller error for this HETP compared to the previous study. Our HETP value will be used in the measurement of the vapour pressure isotopic effect of xenon in the future. In addition, we provide a measurement for the fractionation factor ln(α38−40) = (2.731± 0.017)×10−3 at the nominal boiling point, which has improved error and is consistent with theoretical values.","abstract_has_math":false,"creators":["Emara, Abo-Bakr Mohamed Abdelfattah Mohamed"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:03:41Z","subjects":["Particles (Nuclear physics)"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15574"],"render_values":[{"text":"10.22215/etd/2023-15574","href":"https://doi.org/10.22215/etd/2023-15574","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/40862","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/40862","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F40862","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Emara, Abo-Bakr Mohamed Abdelfattah Mohamed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:08:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:08:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Particles (Nuclear physics)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15574"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/40862"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work presents the calibration for a 14.6 m-high cryogenic distillation column which is performed using argon. This column is located at SNOLAB, an underground lab in Canada, and it is planned to study the potential of using distillation for xenon isotopic enrichment. Our study yields a measurement of the still’s height equivalent to theoretical plate (HETP) of 4.29±0.13 cm, consistent with a previous study using the same packing material. A new approach introduced in this analysis achieves a smaller error for this HETP compared to the previous study. Our HETP value will be used in the measurement of the vapour pressure isotopic effect of xenon in the future. In addition, we provide a measurement for the fractionation factor ln(α38−40) = (2.731± 0.017)×10−3 at the nominal boiling point, which has improved error and is consistent with theoretical values."]},{"key":"dc:title","label":"Title","values":["Argon Calibration of a Cryogenic Distillation Column for Xenon Isotopic Enrichment"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Emara, Abo-Bakr Mohamed Abdelfattah Mohamed"],"dc:date.accessioned":["2025-04-08T20:08:19Z"],"dc:date.available":["2025-04-08T20:08:19Z"],"dc:date.issued":["2023"],"dc:description.abstract":["This work presents the calibration for a 14.6 m-high cryogenic distillation column which is performed using argon. This column is located at SNOLAB, an underground lab in Canada, and it is planned to study the potential of using distillation for xenon isotopic enrichment. Our study yields a measurement of the still’s height equivalent to theoretical plate (HETP) of 4.29±0.13 cm, consistent with a previous study using the same packing material. A new approach introduced in this analysis achieves a smaller error for this HETP compared to the previous study. Our HETP value will be used in the measurement of the vapour pressure isotopic effect of xenon in the future. In addition, we provide a measurement for the fractionation factor ln(α38−40) = (2.731± 0.017)×10−3 at the nominal boiling point, which has improved error and is consistent with theoretical values."],"dc:identifier.doi":["10.22215/etd/2023-15574"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/40862"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Particles (Nuclear physics)"],"dc:title":["Argon Calibration of a Cryogenic Distillation Column for Xenon Isotopic Enrichment"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:03:41Z"}