{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41043"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41043","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Towards Smart Building Maintenance: Leveraging Multi-Source Data and Digital Twins with Ecological Momentary Assessment","abstract":"Complaint management, fault detection and diagnosis (FDD) are critical for building performance and occupants' well-being. Facility management addresses these services with work order logs containing occupant complaints and FDD identifying system faults. This thesis enhances these aspects using existing and new data sources. The first section maximizes existing data (Chapters 2 and 3). Text analytics (Chapter 2) is used to create benchmarks for maintenance performance evaluation and transforms data into visual insights. Additionally, facility management-enabled building information models (FM-BIMs) (Chapter 3) integrate maintenance logs with BIM, enhancing decisionmaking through contextual data exchange. A case study is presented to demonstrate the effectiveness of this methodology. The second section employs novel data collection methods and their application in digital twins (Chapters 4 and 5). Cozie smartwatch app representing micro-ecological assessment gathers occupants’ thermal comfort and air quality feedback. This data source is integrated with building system sensor data. FDD rulesets utilize this data for fault detection, validated by occupants’ accurate feedback. Surveys revealed that occupants seldom report discomfort unless the temperature deviates by 3°C. This approach reduces reporting thresholds, enhancing issue reporting by 29%. Chapter 5 introduces a digital twin framework for maintenance, integrating diverse building system data and real-time insights. Occupant feedback collection methods are diversified through online surveys and a smartwatch app, enhancing indoor quality assessment. The framework supports two tiers of analysis and user interfaces for facility management, demonstrated via a prototype that leverages existing infrastructure. This methodology allows facility management agents to develop digital-twin-enabled workflows bringing multiple real-time data streams together to make more informed decisions. In conclusion, this thesis advances complaint management, FDD, and other maintenance practices by innovating existing and new data sources. The proposed methodologies, from text analytics to digital twin frameworks, empower facility management to enhance building performance and occupant satisfaction proactively.","abstract_html":"Complaint management, fault detection and diagnosis (FDD) are critical for building performance and occupants&#x27; well-being. Facility management addresses these services with work order logs containing occupant complaints and FDD identifying system faults. This thesis enhances these aspects using existing and new data sources. The first section maximizes existing data (Chapters 2 and 3). Text analytics (Chapter 2) is used to create benchmarks for maintenance performance evaluation and transforms data into visual insights. Additionally, facility management-enabled building information models (FM-BIMs) (Chapter 3) integrate maintenance logs with BIM, enhancing decisionmaking through contextual data exchange. A case study is presented to demonstrate the effectiveness of this methodology. The second section employs novel data collection methods and their application in digital twins (Chapters 4 and 5). Cozie smartwatch app representing micro-ecological assessment gathers occupants’ thermal comfort and air quality feedback. This data source is integrated with building system sensor data. FDD rulesets utilize this data for fault detection, validated by occupants’ accurate feedback. Surveys revealed that occupants seldom report discomfort unless the temperature deviates by 3°C. This approach reduces reporting thresholds, enhancing issue reporting by 29%. Chapter 5 introduces a digital twin framework for maintenance, integrating diverse building system data and real-time insights. Occupant feedback collection methods are diversified through online surveys and a smartwatch app, enhancing indoor quality assessment. The framework supports two tiers of analysis and user interfaces for facility management, demonstrated via a prototype that leverages existing infrastructure. This methodology allows facility management agents to develop digital-twin-enabled workflows bringing multiple real-time data streams together to make more informed decisions. In conclusion, this thesis advances complaint management, FDD, and other maintenance practices by innovating existing and new data sources. The proposed methodologies, from text analytics to digital twin frameworks, empower facility management to enhance building performance and occupant satisfaction proactively.","abstract_has_math":false,"creators":["Nojedehi, Pedram"],"institution":"Carleton University","degree_name":"Doctor of Philosophy (Ph.D.)","degree_level":"Doctoral","degree_discipline":"Engineering, Building","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:12:22Z","subjects":["Civil engineering","Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41043"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/41043","href":"https://hdl.handle.net/20.500.14718/41043","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2023-15650","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2023-15650","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F41043","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41043","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nojedehi, Pedram"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:11:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:11:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Building"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (Ph.D.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering","Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15650"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41043"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Complaint management, fault detection and diagnosis (FDD) are critical for building performance and occupants' well-being. Facility management addresses these services with work order logs containing occupant complaints and FDD identifying system faults. This thesis enhances these aspects using existing and new data sources. The first section maximizes existing data (Chapters 2 and 3). Text analytics (Chapter 2) is used to create benchmarks for maintenance performance evaluation and transforms data into visual insights. Additionally, facility management-enabled building information models (FM-BIMs) (Chapter 3) integrate maintenance logs with BIM, enhancing decisionmaking through contextual data exchange. A case study is presented to demonstrate the effectiveness of this methodology. The second section employs novel data collection methods and their application in digital twins (Chapters 4 and 5). Cozie smartwatch app representing micro-ecological assessment gathers occupants’ thermal comfort and air quality feedback. This data source is integrated with building system sensor data. FDD rulesets utilize this data for fault detection, validated by occupants’ accurate feedback. Surveys revealed that occupants seldom report discomfort unless the temperature deviates by 3°C. This approach reduces reporting thresholds, enhancing issue reporting by 29%. Chapter 5 introduces a digital twin framework for maintenance, integrating diverse building system data and real-time insights. Occupant feedback collection methods are diversified through online surveys and a smartwatch app, enhancing indoor quality assessment. The framework supports two tiers of analysis and user interfaces for facility management, demonstrated via a prototype that leverages existing infrastructure. This methodology allows facility management agents to develop digital-twin-enabled workflows bringing multiple real-time data streams together to make more informed decisions. In conclusion, this thesis advances complaint management, FDD, and other maintenance practices by innovating existing and new data sources. The proposed methodologies, from text analytics to digital twin frameworks, empower facility management to enhance building performance and occupant satisfaction proactively."]},{"key":"dc:title","label":"Title","values":["Towards Smart Building Maintenance: Leveraging Multi-Source Data and Digital Twins with Ecological Momentary Assessment"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Nojedehi, Pedram"],"dc:date.accessioned":["2025-04-08T20:11:45Z"],"dc:date.available":["2025-04-08T20:11:45Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Complaint management, fault detection and diagnosis (FDD) are critical for building performance and occupants' well-being. Facility management addresses these services with work order logs containing occupant complaints and FDD identifying system faults. This thesis enhances these aspects using existing and new data sources. The first section maximizes existing data (Chapters 2 and 3). Text analytics (Chapter 2) is used to create benchmarks for maintenance performance evaluation and transforms data into visual insights. Additionally, facility management-enabled building information models (FM-BIMs) (Chapter 3) integrate maintenance logs with BIM, enhancing decisionmaking through contextual data exchange. A case study is presented to demonstrate the effectiveness of this methodology. The second section employs novel data collection methods and their application in digital twins (Chapters 4 and 5). Cozie smartwatch app representing micro-ecological assessment gathers occupants’ thermal comfort and air quality feedback. This data source is integrated with building system sensor data. FDD rulesets utilize this data for fault detection, validated by occupants’ accurate feedback. Surveys revealed that occupants seldom report discomfort unless the temperature deviates by 3°C. This approach reduces reporting thresholds, enhancing issue reporting by 29%. Chapter 5 introduces a digital twin framework for maintenance, integrating diverse building system data and real-time insights. Occupant feedback collection methods are diversified through online surveys and a smartwatch app, enhancing indoor quality assessment. The framework supports two tiers of analysis and user interfaces for facility management, demonstrated via a prototype that leverages existing infrastructure. This methodology allows facility management agents to develop digital-twin-enabled workflows bringing multiple real-time data streams together to make more informed decisions. In conclusion, this thesis advances complaint management, FDD, and other maintenance practices by innovating existing and new data sources. The proposed methodologies, from text analytics to digital twin frameworks, empower facility management to enhance building performance and occupant satisfaction proactively."],"dc:identifier.doi":["10.22215/etd/2023-15650"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41043"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering","Mechanical engineering"],"dc:title":["Towards Smart Building Maintenance: Leveraging Multi-Source Data and Digital Twins with Ecological Momentary Assessment"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Building"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Doctor of Philosophy (Ph.D.)"]},"updated_at":"2026-11-19T07:12:22Z"}