{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41046"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41046","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Energy Calibration in the DEAP-3600 Dark Matter Detector","abstract":"DEAP-3600 is a direct dark matter detector and is a single phase liquid argon scintillator using pulse-shape discrimination techniques to remove backgrounds. This allows for the sensitivity required to measure spin-independent interactions with Weakly Interacting Massive Particles (WIMPs), a leading dark matter candidate. A new corrected energy variable has been developed using a three year data set. This calibration corrects for the number of working photomultiplier tubes and time drift with a mean uncertainty of 3.4 × 10^(−4) %. The uncertainty of the energy due to position dependence is constrained to be < 3.5% between the center and the edge of the detector. The effect of the energy scale non-linearity has been determined up to ~ 10 MeV, with the uncertainty constrained to be < 7.3%. The overall residual uncertainty of the measured energy is constrained to be < 8.1%, assuming no correlations between the dependencies.","abstract_html":"DEAP-3600 is a direct dark matter detector and is a single phase liquid argon scintillator using pulse-shape discrimination techniques to remove backgrounds. This allows for the sensitivity required to measure spin-independent interactions with Weakly Interacting Massive Particles (WIMPs), a leading dark matter candidate. A new corrected energy variable has been developed using a three year data set. This calibration corrects for the number of working photomultiplier tubes and time drift with a mean uncertainty of 3.4 × 10^(−4) %. The uncertainty of the energy due to position dependence is constrained to be &lt; 3.5% between the center and the edge of the detector. The effect of the energy scale non-linearity has been determined up to ~ 10 MeV, with the uncertainty constrained to be &lt; 7.3%. The overall residual uncertainty of the measured energy is constrained to be &lt; 8.1%, assuming no correlations between the dependencies.","abstract_has_math":false,"creators":["Sobotkiewich, Kazmir"],"institution":"Carleton University","degree_name":"Master of Science (M.Sc.)","degree_level":"Master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:05:47Z","subjects":["Particles (Nuclear physics)"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41046"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/41046","href":"https://hdl.handle.net/20.500.14718/41046","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2023-15763","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2023-15763","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acarleton%3Aoai%3Acarleton.scholaris.ca%3A20.500.14718%2F41046","prefix":"oai_dc"},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41046","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Sobotkiewich, Kazmir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:11:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:11:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Particles (Nuclear physics)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15763"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41046"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["DEAP-3600 is a direct dark matter detector and is a single phase liquid argon scintillator using pulse-shape discrimination techniques to remove backgrounds. This allows for the sensitivity required to measure spin-independent interactions with Weakly Interacting Massive Particles (WIMPs), a leading dark matter candidate. A new corrected energy variable has been developed using a three year data set. This calibration corrects for the number of working photomultiplier tubes and time drift with a mean uncertainty of 3.4 × 10^(−4) %. The uncertainty of the energy due to position dependence is constrained to be < 3.5% between the center and the edge of the detector. The effect of the energy scale non-linearity has been determined up to ~ 10 MeV, with the uncertainty constrained to be < 7.3%. The overall residual uncertainty of the measured energy is constrained to be < 8.1%, assuming no correlations between the dependencies."]},{"key":"dc:title","label":"Title","values":["Energy Calibration in the DEAP-3600 Dark Matter Detector"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Sobotkiewich, Kazmir"],"dc:date.accessioned":["2025-04-08T20:11:48Z"],"dc:date.available":["2025-04-08T20:11:48Z"],"dc:date.issued":["2023"],"dc:description.abstract":["DEAP-3600 is a direct dark matter detector and is a single phase liquid argon scintillator using pulse-shape discrimination techniques to remove backgrounds. This allows for the sensitivity required to measure spin-independent interactions with Weakly Interacting Massive Particles (WIMPs), a leading dark matter candidate. A new corrected energy variable has been developed using a three year data set. This calibration corrects for the number of working photomultiplier tubes and time drift with a mean uncertainty of 3.4 × 10^(−4) %. The uncertainty of the energy due to position dependence is constrained to be < 3.5% between the center and the edge of the detector. The effect of the energy scale non-linearity has been determined up to ~ 10 MeV, with the uncertainty constrained to be < 7.3%. The overall residual uncertainty of the measured energy is constrained to be < 8.1%, assuming no correlations between the dependencies."],"dc:identifier.doi":["10.22215/etd/2023-15763"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41046"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Particles (Nuclear physics)"],"dc:title":["Energy Calibration in the DEAP-3600 Dark Matter Detector"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T07:05:47Z"}