{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41119"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41119","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"The effect of pH and alkalinity on drinking water biofiltration performance","abstract":"Two bench-scale biofiltration columns were monitored to examine the influence of water-quality parameters, including pH and alkalinity to enhance drinking water biofiltration efficiency. The biofilters were operated at four pH values with low and high alkalinity levels. Applying a higher pH level of 7.5 compared to 6.0 led to similar total organic carbon (TOC) removal efficiency. Raising the pH to 10.0 resulted in a significantly lower TOC removal efficiency. Increasing pH was also observed to influence ammonia removal significantly such that ammonia removal efficiency improved from 13% at pH 6.0 to 93% at pH 10.0; however, the higher pH was no longer attributed to biological removal but ammonia stripping. The assessment of theoretical oxygen demand revealed that dissolved oxygen (DO) availability was an influential factor in nitrification efficiency. No direct correlation was observed between adenosine triphosphate (ATP) and TOC removal. Overall, pH 7.5 demonstrated optimal biofilter conditions.","abstract_html":"Two bench-scale biofiltration columns were monitored to examine the influence of water-quality parameters, including pH and alkalinity to enhance drinking water biofiltration efficiency. The biofilters were operated at four pH values with low and high alkalinity levels. Applying a higher pH level of 7.5 compared to 6.0 led to similar total organic carbon (TOC) removal efficiency. Raising the pH to 10.0 resulted in a significantly lower TOC removal efficiency. Increasing pH was also observed to influence ammonia removal significantly such that ammonia removal efficiency improved from 13% at pH 6.0 to 93% at pH 10.0; however, the higher pH was no longer attributed to biological removal but ammonia stripping. The assessment of theoretical oxygen demand revealed that dissolved oxygen (DO) availability was an influential factor in nitrification efficiency. No direct correlation was observed between adenosine triphosphate (ATP) and TOC removal. Overall, pH 7.5 demonstrated optimal biofilter conditions.","abstract_has_math":false,"creators":["Pirouz Hamidi, Hamideh"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T06:52:59Z","subjects":["Biology"],"languages":["en"],"rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41119"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/41119","href":"https://hdl.handle.net/20.500.14718/41119","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2019-13880","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2019-13880","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41119","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Pirouz Hamidi, Hamideh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:13:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:13:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2019-13880"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41119"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Two bench-scale biofiltration columns were monitored to examine the influence of water-quality parameters, including pH and alkalinity to enhance drinking water biofiltration efficiency. The biofilters were operated at four pH values with low and high alkalinity levels. Applying a higher pH level of 7.5 compared to 6.0 led to similar total organic carbon (TOC) removal efficiency. Raising the pH to 10.0 resulted in a significantly lower TOC removal efficiency. Increasing pH was also observed to influence ammonia removal significantly such that ammonia removal efficiency improved from 13% at pH 6.0 to 93% at pH 10.0; however, the higher pH was no longer attributed to biological removal but ammonia stripping. The assessment of theoretical oxygen demand revealed that dissolved oxygen (DO) availability was an influential factor in nitrification efficiency. No direct correlation was observed between adenosine triphosphate (ATP) and TOC removal. Overall, pH 7.5 demonstrated optimal biofilter conditions."]},{"key":"dc:title","label":"Title","values":["The effect of pH and alkalinity on drinking water biofiltration performance"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Pirouz Hamidi, Hamideh"],"dc:date.accessioned":["2025-04-08T20:13:14Z"],"dc:date.available":["2025-04-08T20:13:14Z"],"dc:date.issued":["2019"],"dc:description.abstract":["Two bench-scale biofiltration columns were monitored to examine the influence of water-quality parameters, including pH and alkalinity to enhance drinking water biofiltration efficiency. The biofilters were operated at four pH values with low and high alkalinity levels. Applying a higher pH level of 7.5 compared to 6.0 led to similar total organic carbon (TOC) removal efficiency. Raising the pH to 10.0 resulted in a significantly lower TOC removal efficiency. Increasing pH was also observed to influence ammonia removal significantly such that ammonia removal efficiency improved from 13% at pH 6.0 to 93% at pH 10.0; however, the higher pH was no longer attributed to biological removal but ammonia stripping. The assessment of theoretical oxygen demand revealed that dissolved oxygen (DO) availability was an influential factor in nitrification efficiency. No direct correlation was observed between adenosine triphosphate (ATP) and TOC removal. Overall, pH 7.5 demonstrated optimal biofilter conditions."],"dc:identifier.doi":["10.22215/etd/2019-13880"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41119"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2019 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biology"],"dc:title":["The effect of pH and alkalinity on drinking water biofiltration performance"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:52:59Z"}