{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41175"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41175","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"A Pulsating Heat Pipe Based Thermal Management System for Lithium-ion Batteries","abstract":"Under high-intensity usage, an effective thermal management system is essential to control battery pack temperature within the desired range to guarantee battery safety and ensure a proper life cycle. This study developed a pulsating heat pipe (PHP) based thermal management system to promote battery temperature control. The system was tested for a large battery pack (2 kWh) under mild and severe ambient conditions via ANSYS Fluent simulation. A sensitivity study identified optimal PHP dimensions regarding the battery pack. The performance of PHP for both small and large scales was also evaluated. The system's effectiveness was compared to classical battery thermal management (BTM) systems such as forced air cooling, sidewall water cooling, and traditional heat pipes. The results demonstrated that the developed PHP-based passive cooling system effectively controls temperature, saves space, and reduces power consumption.","abstract_html":"Under high-intensity usage, an effective thermal management system is essential to control battery pack temperature within the desired range to guarantee battery safety and ensure a proper life cycle. This study developed a pulsating heat pipe (PHP) based thermal management system to promote battery temperature control. The system was tested for a large battery pack (2 kWh) under mild and severe ambient conditions via ANSYS Fluent simulation. A sensitivity study identified optimal PHP dimensions regarding the battery pack. The performance of PHP for both small and large scales was also evaluated. The system&#x27;s effectiveness was compared to classical battery thermal management (BTM) systems such as forced air cooling, sidewall water cooling, and traditional heat pipes. The results demonstrated that the developed PHP-based passive cooling system effectively controls temperature, saves space, and reduces power consumption.","abstract_has_math":false,"creators":["Liu, Jianyu"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T06:55:28Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41175"],"render_values":[{"text":"https://hdl.handle.net/20.500.14718/41175","href":"https://hdl.handle.net/20.500.14718/41175","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.22215/etd/2021-14707","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.22215/etd/2021-14707","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41175","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Liu, Jianyu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:14:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:14:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14707"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41175"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Under high-intensity usage, an effective thermal management system is essential to control battery pack temperature within the desired range to guarantee battery safety and ensure a proper life cycle. This study developed a pulsating heat pipe (PHP) based thermal management system to promote battery temperature control. The system was tested for a large battery pack (2 kWh) under mild and severe ambient conditions via ANSYS Fluent simulation. A sensitivity study identified optimal PHP dimensions regarding the battery pack. The performance of PHP for both small and large scales was also evaluated. The system's effectiveness was compared to classical battery thermal management (BTM) systems such as forced air cooling, sidewall water cooling, and traditional heat pipes. The results demonstrated that the developed PHP-based passive cooling system effectively controls temperature, saves space, and reduces power consumption."]},{"key":"dc:title","label":"Title","values":["A Pulsating Heat Pipe Based Thermal Management System for Lithium-ion Batteries"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Liu, Jianyu"],"dc:date.accessioned":["2025-04-08T20:14:17Z"],"dc:date.available":["2025-04-08T20:14:17Z"],"dc:date.issued":["2021"],"dc:description.abstract":["Under high-intensity usage, an effective thermal management system is essential to control battery pack temperature within the desired range to guarantee battery safety and ensure a proper life cycle. This study developed a pulsating heat pipe (PHP) based thermal management system to promote battery temperature control. The system was tested for a large battery pack (2 kWh) under mild and severe ambient conditions via ANSYS Fluent simulation. A sensitivity study identified optimal PHP dimensions regarding the battery pack. The performance of PHP for both small and large scales was also evaluated. The system's effectiveness was compared to classical battery thermal management (BTM) systems such as forced air cooling, sidewall water cooling, and traditional heat pipes. The results demonstrated that the developed PHP-based passive cooling system effectively controls temperature, saves space, and reduces power consumption."],"dc:identifier.doi":["10.22215/etd/2021-14707"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41175"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["A Pulsating Heat Pipe Based Thermal Management System for Lithium-ion Batteries"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:55:28Z"}