{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41235"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41235","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"A Numerical and Experimental Analysis of a Transcritical, CO2 Heat Pump Water Heater","abstract":"Due to the environmental concerns regarding traditional refrigerants, carbon dioxide (CO2) is being studied as an alternative refrigerant in HPWHs. In this study, a commercially available, transcritical CO2 HPWH was numerically and experimentally assessed. This included developing a model of the CO2 HPWH and calibrating it with experimental data. The model was theoretically verified and utilized to predict the cycle pressures and compressor isentropic efficiency. While the predicted discharge pressures were within the expected range, the significant biases indicate that further work is required to increase the model accuracy. Additionally, study of the control system indicated that the water outlet temperature controls the water pump, the ambient temperature controls the compressor and evaporator fan, and that the expansion valve controls the high side pressure. Lastly, the performance data shows that the HPWH achieves the best performance at ambient air temperatures above 0°C and at water inlet temperatures below 30°C.","abstract_html":"Due to the environmental concerns regarding traditional refrigerants, carbon dioxide (CO2) is being studied as an alternative refrigerant in HPWHs. In this study, a commercially available, transcritical CO2 HPWH was numerically and experimentally assessed. This included developing a model of the CO2 HPWH and calibrating it with experimental data. The model was theoretically verified and utilized to predict the cycle pressures and compressor isentropic efficiency. While the predicted discharge pressures were within the expected range, the significant biases indicate that further work is required to increase the model accuracy. Additionally, study of the control system indicated that the water outlet temperature controls the water pump, the ambient temperature controls the compressor and evaporator fan, and that the expansion valve controls the high side pressure. Lastly, the performance data shows that the HPWH achieves the best performance at ambient air temperatures above 0°C and at water inlet temperatures below 30°C.","abstract_has_math":false,"creators":["Lewry, Kayla Jean"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Sustainable Energy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T06:54:49Z","subjects":["Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14736"],"render_values":[{"text":"10.22215/etd/2021-14736","href":"https://doi.org/10.22215/etd/2021-14736","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41235","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41235","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41235","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lewry, Kayla Jean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:15:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:15:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sustainable Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14736"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41235"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Due to the environmental concerns regarding traditional refrigerants, carbon dioxide (CO2) is being studied as an alternative refrigerant in HPWHs. In this study, a commercially available, transcritical CO2 HPWH was numerically and experimentally assessed. This included developing a model of the CO2 HPWH and calibrating it with experimental data. The model was theoretically verified and utilized to predict the cycle pressures and compressor isentropic efficiency. While the predicted discharge pressures were within the expected range, the significant biases indicate that further work is required to increase the model accuracy. Additionally, study of the control system indicated that the water outlet temperature controls the water pump, the ambient temperature controls the compressor and evaporator fan, and that the expansion valve controls the high side pressure. Lastly, the performance data shows that the HPWH achieves the best performance at ambient air temperatures above 0°C and at water inlet temperatures below 30°C."]},{"key":"dc:title","label":"Title","values":["A Numerical and Experimental Analysis of a Transcritical, CO2 Heat Pump Water Heater"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Lewry, Kayla Jean"],"dc:date.accessioned":["2025-04-08T20:15:18Z"],"dc:date.available":["2025-04-08T20:15:18Z"],"dc:date.issued":["2021"],"dc:description.abstract":["Due to the environmental concerns regarding traditional refrigerants, carbon dioxide (CO2) is being studied as an alternative refrigerant in HPWHs. In this study, a commercially available, transcritical CO2 HPWH was numerically and experimentally assessed. This included developing a model of the CO2 HPWH and calibrating it with experimental data. The model was theoretically verified and utilized to predict the cycle pressures and compressor isentropic efficiency. While the predicted discharge pressures were within the expected range, the significant biases indicate that further work is required to increase the model accuracy. Additionally, study of the control system indicated that the water outlet temperature controls the water pump, the ambient temperature controls the compressor and evaporator fan, and that the expansion valve controls the high side pressure. Lastly, the performance data shows that the HPWH achieves the best performance at ambient air temperatures above 0°C and at water inlet temperatures below 30°C."],"dc:identifier.doi":["10.22215/etd/2021-14736"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41235"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Mechanical engineering"],"dc:title":["A Numerical and Experimental Analysis of a Transcritical, CO2 Heat Pump Water Heater"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Sustainable Energy"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:54:49Z"}