{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41491"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41491","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Development of a Simplified Method for Optimally Sizing Hot Water Storage Tanks Subject to Short-Term Intermittent Charge/Discharge Cycles","abstract":"Hot water storage plays a pivotal role in the transition to low carbon energy systems by increasing energy efficiency and allowing a range of non-conventional intermittent energy sources in the energy mix. In the current study, a simple analytical method is developed to optimally size hot water storage tanks using only the system residual heating profile and the following system characteristics: the heat source temperature, the load service temperature, the auxiliary energy price, and the tank's surrounding temperature. Results show that all scenarios with a source temperature of 95°C, a source to load temperature difference of at least 35°C, and an auxiliary energy price of at least 0.105 USD/kWh have associated R2 values of 0.8 or greater, indicating the sizing method is able to predict the optimal storage tank volume with a high degree of confidence. A case study is presented for a hypothetical solar-thermal DHW system in Montréal, Canada.","abstract_html":"Hot water storage plays a pivotal role in the transition to low carbon energy systems by increasing energy efficiency and allowing a range of non-conventional intermittent energy sources in the energy mix. In the current study, a simple analytical method is developed to optimally size hot water storage tanks using only the system residual heating profile and the following system characteristics: the heat source temperature, the load service temperature, the auxiliary energy price, and the tank&#x27;s surrounding temperature. Results show that all scenarios with a source temperature of 95°C, a source to load temperature difference of at least 35°C, and an auxiliary energy price of at least 0.105 USD/kWh have associated R2 values of 0.8 or greater, indicating the sizing method is able to predict the optimal storage tank volume with a high degree of confidence. A case study is presented for a hypothetical solar-thermal DHW system in Montréal, Canada.","abstract_has_math":false,"creators":["Stalinski, Danisz"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Sustainable Energy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T07:00:43Z","subjects":["Force and energy"],"languages":["en"],"rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-14191"],"render_values":[{"text":"10.22215/etd/2020-14191","href":"https://doi.org/10.22215/etd/2020-14191","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41491","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41491","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41491","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Stalinski, Danisz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:20:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:20:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Sustainable Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Force and energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2020-14191"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41491"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hot water storage plays a pivotal role in the transition to low carbon energy systems by increasing energy efficiency and allowing a range of non-conventional intermittent energy sources in the energy mix. In the current study, a simple analytical method is developed to optimally size hot water storage tanks using only the system residual heating profile and the following system characteristics: the heat source temperature, the load service temperature, the auxiliary energy price, and the tank's surrounding temperature. Results show that all scenarios with a source temperature of 95°C, a source to load temperature difference of at least 35°C, and an auxiliary energy price of at least 0.105 USD/kWh have associated R2 values of 0.8 or greater, indicating the sizing method is able to predict the optimal storage tank volume with a high degree of confidence. A case study is presented for a hypothetical solar-thermal DHW system in Montréal, Canada."]},{"key":"dc:title","label":"Title","values":["Development of a Simplified Method for Optimally Sizing Hot Water Storage Tanks Subject to Short-Term Intermittent Charge/Discharge Cycles"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Stalinski, Danisz"],"dc:date.accessioned":["2025-04-08T20:20:04Z"],"dc:date.available":["2025-04-08T20:20:04Z"],"dc:date.issued":["2020"],"dc:description.abstract":["Hot water storage plays a pivotal role in the transition to low carbon energy systems by increasing energy efficiency and allowing a range of non-conventional intermittent energy sources in the energy mix. In the current study, a simple analytical method is developed to optimally size hot water storage tanks using only the system residual heating profile and the following system characteristics: the heat source temperature, the load service temperature, the auxiliary energy price, and the tank's surrounding temperature. Results show that all scenarios with a source temperature of 95°C, a source to load temperature difference of at least 35°C, and an auxiliary energy price of at least 0.105 USD/kWh have associated R2 values of 0.8 or greater, indicating the sizing method is able to predict the optimal storage tank volume with a high degree of confidence. A case study is presented for a hypothetical solar-thermal DHW system in Montréal, Canada."],"dc:identifier.doi":["10.22215/etd/2020-14191"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41491"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2020 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Force and energy"],"dc:title":["Development of a Simplified Method for Optimally Sizing Hot Water Storage Tanks Subject to Short-Term Intermittent Charge/Discharge Cycles"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Sustainable Energy"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:00:43Z"}