{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41524"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41524","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Durability Characterization of a High Performance Building Envelope with Vacuum Insulation Panels and Energy Recovery Ventilation","abstract":"Vacuum insulation panels (VIPs) can help achieve thin, highly insulated building envelopes, but poor implementation and insufficient ventilation can lead to durability issues. This thesis describes a field study that was used to characterize the durability of a research house with a thin, VIP-integrated building envelope and an energy recovery ventilator (ERV). The study employed long term hygrothermal monitoring of the building envelope and various tests to evaluate the insulation performance, airtightness, and ventilation effectiveness. The impacts of VIPs and ventilation on durability were discussed, with emphasis on moisture buffering, drying potential, mold growth risk, and VIP aging. The house demonstrated exceptional insulation performance with no risk of visible mold growth during the study. The walls and floor showed acceptable conditions for VIP longevity, and the ERV showed a potential to sufficiently buffer indoor moisture loads. Recommendations were provided to improve the durability and efficiency of the house.","abstract_html":"Vacuum insulation panels (VIPs) can help achieve thin, highly insulated building envelopes, but poor implementation and insufficient ventilation can lead to durability issues. This thesis describes a field study that was used to characterize the durability of a research house with a thin, VIP-integrated building envelope and an energy recovery ventilator (ERV). The study employed long term hygrothermal monitoring of the building envelope and various tests to evaluate the insulation performance, airtightness, and ventilation effectiveness. The impacts of VIPs and ventilation on durability were discussed, with emphasis on moisture buffering, drying potential, mold growth risk, and VIP aging. The house demonstrated exceptional insulation performance with no risk of visible mold growth during the study. The walls and floor showed acceptable conditions for VIP longevity, and the ERV showed a potential to sufficiently buffer indoor moisture loads. Recommendations were provided to improve the durability and efficiency of the house.","abstract_has_math":false,"creators":["Campbell, Christopher Lee"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Mechanical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T06:55:03Z","subjects":["Civil engineering","Mechanical engineering"],"languages":["en"],"rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14505"],"render_values":[{"text":"10.22215/etd/2021-14505","href":"https://doi.org/10.22215/etd/2021-14505","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41524","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41524","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41524","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Campbell, Christopher Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:20:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:20:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Mechanical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering","Mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14505"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41524"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Vacuum insulation panels (VIPs) can help achieve thin, highly insulated building envelopes, but poor implementation and insufficient ventilation can lead to durability issues. This thesis describes a field study that was used to characterize the durability of a research house with a thin, VIP-integrated building envelope and an energy recovery ventilator (ERV). The study employed long term hygrothermal monitoring of the building envelope and various tests to evaluate the insulation performance, airtightness, and ventilation effectiveness. The impacts of VIPs and ventilation on durability were discussed, with emphasis on moisture buffering, drying potential, mold growth risk, and VIP aging. The house demonstrated exceptional insulation performance with no risk of visible mold growth during the study. The walls and floor showed acceptable conditions for VIP longevity, and the ERV showed a potential to sufficiently buffer indoor moisture loads. Recommendations were provided to improve the durability and efficiency of the house."]},{"key":"dc:title","label":"Title","values":["Durability Characterization of a High Performance Building Envelope with Vacuum Insulation Panels and Energy Recovery Ventilation"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Campbell, Christopher Lee"],"dc:date.accessioned":["2025-04-08T20:20:55Z"],"dc:date.available":["2025-04-08T20:20:55Z"],"dc:date.issued":["2021"],"dc:description.abstract":["Vacuum insulation panels (VIPs) can help achieve thin, highly insulated building envelopes, but poor implementation and insufficient ventilation can lead to durability issues. This thesis describes a field study that was used to characterize the durability of a research house with a thin, VIP-integrated building envelope and an energy recovery ventilator (ERV). The study employed long term hygrothermal monitoring of the building envelope and various tests to evaluate the insulation performance, airtightness, and ventilation effectiveness. The impacts of VIPs and ventilation on durability were discussed, with emphasis on moisture buffering, drying potential, mold growth risk, and VIP aging. The house demonstrated exceptional insulation performance with no risk of visible mold growth during the study. The walls and floor showed acceptable conditions for VIP longevity, and the ERV showed a potential to sufficiently buffer indoor moisture loads. Recommendations were provided to improve the durability and efficiency of the house."],"dc:identifier.doi":["10.22215/etd/2021-14505"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41524"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering","Mechanical engineering"],"dc:title":["Durability Characterization of a High Performance Building Envelope with Vacuum Insulation Panels and Energy Recovery Ventilation"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Mechanical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:55:03Z"}