{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41561"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41561","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Universal Control of Permanent Magnet Synchronous Motors with Uncertain Dynamics","abstract":"Permanent magnet synchronous motors (PMSMs) are used in various industrial applications and many theoretical advances have been achieved in the domain of PMSM control. However, more research is needed in area of self-commissioning drives which can operate with very minimum information of motor parameters. This thesis focuses on the universal control design of PMSMs and uses two control methods: conventional field-oriented vector control and simplified control. In vector control, the classical proportional-integral (PI) controller is used to control the d-q axis currents and speed of the PMSM. The main aim is to determine the PI controller gains using an empirical study and generalized mathematical expressions. In vector control, these equations use power ratings, while in simplified control, the product of number of pole pairs and flux linkage is used for automatic gain calculation. Validation of both the proposed control strategies is done in MATLAB/Simulink, and satisfactory results are obtained.","abstract_html":"Permanent magnet synchronous motors (PMSMs) are used in various industrial applications and many theoretical advances have been achieved in the domain of PMSM control. However, more research is needed in area of self-commissioning drives which can operate with very minimum information of motor parameters. This thesis focuses on the universal control design of PMSMs and uses two control methods: conventional field-oriented vector control and simplified control. In vector control, the classical proportional-integral (PI) controller is used to control the d-q axis currents and speed of the PMSM. The main aim is to determine the PI controller gains using an empirical study and generalized mathematical expressions. In vector control, these equations use power ratings, while in simplified control, the product of number of pole pairs and flux linkage is used for automatic gain calculation. Validation of both the proposed control strategies is done in MATLAB/Simulink, and satisfactory results are obtained.","abstract_has_math":false,"creators":["Lakhe, Rishil Kirankumar"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T06:54:02Z","subjects":["Electrical engineering","Industrial engineering","Robotics"],"languages":["en"],"rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14390"],"render_values":[{"text":"10.22215/etd/2021-14390","href":"https://doi.org/10.22215/etd/2021-14390","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41561","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41561","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41561","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lakhe, Rishil Kirankumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:21:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:21:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Industrial engineering","Robotics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2021-14390"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41561"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Permanent magnet synchronous motors (PMSMs) are used in various industrial applications and many theoretical advances have been achieved in the domain of PMSM control. However, more research is needed in area of self-commissioning drives which can operate with very minimum information of motor parameters. This thesis focuses on the universal control design of PMSMs and uses two control methods: conventional field-oriented vector control and simplified control. In vector control, the classical proportional-integral (PI) controller is used to control the d-q axis currents and speed of the PMSM. The main aim is to determine the PI controller gains using an empirical study and generalized mathematical expressions. In vector control, these equations use power ratings, while in simplified control, the product of number of pole pairs and flux linkage is used for automatic gain calculation. Validation of both the proposed control strategies is done in MATLAB/Simulink, and satisfactory results are obtained."]},{"key":"dc:title","label":"Title","values":["Universal Control of Permanent Magnet Synchronous Motors with Uncertain Dynamics"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Lakhe, Rishil Kirankumar"],"dc:date.accessioned":["2025-04-08T20:21:34Z"],"dc:date.available":["2025-04-08T20:21:34Z"],"dc:date.issued":["2021"],"dc:description.abstract":["Permanent magnet synchronous motors (PMSMs) are used in various industrial applications and many theoretical advances have been achieved in the domain of PMSM control. However, more research is needed in area of self-commissioning drives which can operate with very minimum information of motor parameters. This thesis focuses on the universal control design of PMSMs and uses two control methods: conventional field-oriented vector control and simplified control. In vector control, the classical proportional-integral (PI) controller is used to control the d-q axis currents and speed of the PMSM. The main aim is to determine the PI controller gains using an empirical study and generalized mathematical expressions. In vector control, these equations use power ratings, while in simplified control, the product of number of pole pairs and flux linkage is used for automatic gain calculation. Validation of both the proposed control strategies is done in MATLAB/Simulink, and satisfactory results are obtained."],"dc:identifier.doi":["10.22215/etd/2021-14390"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41561"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2021 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Industrial engineering","Robotics"],"dc:title":["Universal Control of Permanent Magnet Synchronous Motors with Uncertain Dynamics"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:54:02Z"}