{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41644"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41644","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Data-driven Modeling of Green Roof Thermal Performance in Ottawa, Canada.","abstract":"This research investigates the thermal performance of a green roof in Ottawa, Canada. In chapter 1, the measured thermal performance of the green roof is defined as the percent reduction in total monthly heat exchange promoted by the green roof, relative to a conventional roof. Thermal performance ranged between 31.0 - 62.8% between May and September in 2016 and 2017, with reduced performance in the shoulder and winter seasons. In chapter 2, a resistor-capacitor (RC) and implicit finite difference (FD) model are developed, calibrated, and validated over the same period and are used to predict hourly rates of heat flux and thermal performance. Predicted heat flux exhibited a root-mean-square-error between 0.51 - 1.0 W/m2 and 0.41 - 0.81 W/m2 for the RC and FD models, respectively, in 2016.","abstract_html":"This research investigates the thermal performance of a green roof in Ottawa, Canada. In chapter 1, the measured thermal performance of the green roof is defined as the percent reduction in total monthly heat exchange promoted by the green roof, relative to a conventional roof. Thermal performance ranged between 31.0 - 62.8% between May and September in 2016 and 2017, with reduced performance in the shoulder and winter seasons. In chapter 2, a resistor-capacitor (RC) and implicit finite difference (FD) model are developed, calibrated, and validated over the same period and are used to predict hourly rates of heat flux and thermal performance. Predicted heat flux exhibited a root-mean-square-error between 0.51 - 1.0 W/m2 and 0.41 - 0.81 W/m2 for the RC and FD models, respectively, in 2016.","abstract_has_math":false,"creators":["Gunn, Peter"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Environmental","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:11:36Z","subjects":["Environmental engineering","Green roofs (Gardening)"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15275"],"render_values":[{"text":"10.22215/etd/2022-15275","href":"https://doi.org/10.22215/etd/2022-15275","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41644","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41644","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41644","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gunn, Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:23:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:23:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Environmental"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Environmental engineering","Green roofs (Gardening)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15275"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41644"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research investigates the thermal performance of a green roof in Ottawa, Canada. In chapter 1, the measured thermal performance of the green roof is defined as the percent reduction in total monthly heat exchange promoted by the green roof, relative to a conventional roof. Thermal performance ranged between 31.0 - 62.8% between May and September in 2016 and 2017, with reduced performance in the shoulder and winter seasons. In chapter 2, a resistor-capacitor (RC) and implicit finite difference (FD) model are developed, calibrated, and validated over the same period and are used to predict hourly rates of heat flux and thermal performance. Predicted heat flux exhibited a root-mean-square-error between 0.51 - 1.0 W/m2 and 0.41 - 0.81 W/m2 for the RC and FD models, respectively, in 2016."]},{"key":"dc:title","label":"Title","values":["Data-driven Modeling of Green Roof Thermal Performance in Ottawa, Canada."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Gunn, Peter"],"dc:date.accessioned":["2025-04-08T20:23:05Z"],"dc:date.available":["2025-04-08T20:23:05Z"],"dc:date.issued":["2022"],"dc:description.abstract":["This research investigates the thermal performance of a green roof in Ottawa, Canada. In chapter 1, the measured thermal performance of the green roof is defined as the percent reduction in total monthly heat exchange promoted by the green roof, relative to a conventional roof. Thermal performance ranged between 31.0 - 62.8% between May and September in 2016 and 2017, with reduced performance in the shoulder and winter seasons. In chapter 2, a resistor-capacitor (RC) and implicit finite difference (FD) model are developed, calibrated, and validated over the same period and are used to predict hourly rates of heat flux and thermal performance. Predicted heat flux exhibited a root-mean-square-error between 0.51 - 1.0 W/m2 and 0.41 - 0.81 W/m2 for the RC and FD models, respectively, in 2016."],"dc:identifier.doi":["10.22215/etd/2022-15275"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41644"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Environmental engineering","Green roofs (Gardening)"],"dc:title":["Data-driven Modeling of Green Roof Thermal Performance in Ottawa, Canada."],"dc:type":["thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Environmental"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:11:36Z"}