{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41649"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41649","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"An Automated System to Assess Air Space Size in Histopathology Images of Lung Tissue","abstract":"The mean linear intercept (MLI) score is a useful and common approach for quantifying lung structure in histopathological images. This thesis describes a system developed to calculate the MLI score in a fully automated manner. The system was tested using 20 WSIs from mice. The root-mean-squared deviation between the MLI score of the proposed method and a human rater was 5.73 (standard deviation 5.65), and there was a very strong correlation (r=0.9931). Biases for the indirect method of MLI scoring are examined and shown to account for the differences with the direct MLI scores. Results suggest that shorter guideline length and smaller number of accepted FOV images have a higher standard error when estimating the MLI score when compared to longer guideline lengths and higher number of accepted FOV images. The proposed automated system provides an efficient, accurate, and accessible method that could replace current manual and semi-automated techniques.","abstract_html":"The mean linear intercept (MLI) score is a useful and common approach for quantifying lung structure in histopathological images. This thesis describes a system developed to calculate the MLI score in a fully automated manner. The system was tested using 20 WSIs from mice. The root-mean-squared deviation between the MLI score of the proposed method and a human rater was 5.73 (standard deviation 5.65), and there was a very strong correlation (r=0.9931). Biases for the indirect method of MLI scoring are examined and shown to account for the differences with the direct MLI scores. Results suggest that shorter guideline length and smaller number of accepted FOV images have a higher standard error when estimating the MLI score when compared to longer guideline lengths and higher number of accepted FOV images. The proposed automated system provides an efficient, accurate, and accessible method that could replace current manual and semi-automated techniques.","abstract_has_math":false,"creators":["Politis, Diego Andreas"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Biomedical","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:12:01Z","subjects":["Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15308"],"render_values":[{"text":"10.22215/etd/2022-15308","href":"https://doi.org/10.22215/etd/2022-15308","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41649","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41649","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41649","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Politis, Diego Andreas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:23:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:23:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Biomedical"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15308"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41649"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The mean linear intercept (MLI) score is a useful and common approach for quantifying lung structure in histopathological images. This thesis describes a system developed to calculate the MLI score in a fully automated manner. The system was tested using 20 WSIs from mice. The root-mean-squared deviation between the MLI score of the proposed method and a human rater was 5.73 (standard deviation 5.65), and there was a very strong correlation (r=0.9931). Biases for the indirect method of MLI scoring are examined and shown to account for the differences with the direct MLI scores. Results suggest that shorter guideline length and smaller number of accepted FOV images have a higher standard error when estimating the MLI score when compared to longer guideline lengths and higher number of accepted FOV images. The proposed automated system provides an efficient, accurate, and accessible method that could replace current manual and semi-automated techniques."]},{"key":"dc:title","label":"Title","values":["An Automated System to Assess Air Space Size in Histopathology Images of Lung Tissue"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Politis, Diego Andreas"],"dc:date.accessioned":["2025-04-08T20:23:10Z"],"dc:date.available":["2025-04-08T20:23:10Z"],"dc:date.issued":["2022"],"dc:description.abstract":["The mean linear intercept (MLI) score is a useful and common approach for quantifying lung structure in histopathological images. This thesis describes a system developed to calculate the MLI score in a fully automated manner. The system was tested using 20 WSIs from mice. The root-mean-squared deviation between the MLI score of the proposed method and a human rater was 5.73 (standard deviation 5.65), and there was a very strong correlation (r=0.9931). Biases for the indirect method of MLI scoring are examined and shown to account for the differences with the direct MLI scores. Results suggest that shorter guideline length and smaller number of accepted FOV images have a higher standard error when estimating the MLI score when compared to longer guideline lengths and higher number of accepted FOV images. The proposed automated system provides an efficient, accurate, and accessible method that could replace current manual and semi-automated techniques."],"dc:identifier.doi":["10.22215/etd/2022-15308"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41649"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Biomedical engineering"],"dc:title":["An Automated System to Assess Air Space Size in Histopathology Images of Lung Tissue"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Biomedical"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:12:01Z"}