{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41716"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41716","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Design and Characterization of a Flame Spray Pyrolysis Apparatus to Compare Soot Emissions from Liquid Fuels","abstract":"This study investigates flame spray pyrolysis (FSP) as a simple bench-top tool for comparison of soot emissions from different liquid jet fuels. A sampling assembly is designed for soot collection and particle property analysis. Soot agglomerate size distributions and elemental to total carbon ratios (EC/TC) are measured for three liquid fuels and flame conditions with Reynold's numbers and burner equivalence ratios ranging from 6000 to 9100 and 6.7 to 13.1. Day-to-day variations in the dilution ratio resulted in up to 20% variability in the measured total agglomerate number density and mobility diameters. Geometric mean primary particle and mobility diameter values are below 21 and 113 nm, in excellent agreement with those emitted from jet engines and earlier works using FSP. EC/TC is higher than 0.8 for all flames burning Jet A1, but values as low as 0.55 are measured for soot emitted from SAF burning flames.","abstract_html":"This study investigates flame spray pyrolysis (FSP) as a simple bench-top tool for comparison of soot emissions from different liquid jet fuels. A sampling assembly is designed for soot collection and particle property analysis. Soot agglomerate size distributions and elemental to total carbon ratios (EC/TC) are measured for three liquid fuels and flame conditions with Reynold&#x27;s numbers and burner equivalence ratios ranging from 6000 to 9100 and 6.7 to 13.1. Day-to-day variations in the dilution ratio resulted in up to 20% variability in the measured total agglomerate number density and mobility diameters. Geometric mean primary particle and mobility diameter values are below 21 and 113 nm, in excellent agreement with those emitted from jet engines and earlier works using FSP. EC/TC is higher than 0.8 for all flames burning Jet A1, but values as low as 0.55 are measured for soot emitted from SAF burning flames.","abstract_has_math":false,"creators":["Scott, Jason"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Aerospace","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T06:56:50Z","subjects":["Aerospace engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15367"],"render_values":[{"text":"10.22215/etd/2023-15367","href":"https://doi.org/10.22215/etd/2023-15367","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41716","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41716","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41716","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Scott, Jason"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:24:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:24:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Aerospace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Aerospace engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15367"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41716"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study investigates flame spray pyrolysis (FSP) as a simple bench-top tool for comparison of soot emissions from different liquid jet fuels. A sampling assembly is designed for soot collection and particle property analysis. Soot agglomerate size distributions and elemental to total carbon ratios (EC/TC) are measured for three liquid fuels and flame conditions with Reynold's numbers and burner equivalence ratios ranging from 6000 to 9100 and 6.7 to 13.1. Day-to-day variations in the dilution ratio resulted in up to 20% variability in the measured total agglomerate number density and mobility diameters. Geometric mean primary particle and mobility diameter values are below 21 and 113 nm, in excellent agreement with those emitted from jet engines and earlier works using FSP. EC/TC is higher than 0.8 for all flames burning Jet A1, but values as low as 0.55 are measured for soot emitted from SAF burning flames."]},{"key":"dc:title","label":"Title","values":["Design and Characterization of a Flame Spray Pyrolysis Apparatus to Compare Soot Emissions from Liquid Fuels"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Scott, Jason"],"dc:date.accessioned":["2025-04-08T20:24:20Z"],"dc:date.available":["2025-04-08T20:24:20Z"],"dc:date.issued":["2023"],"dc:description.abstract":["This study investigates flame spray pyrolysis (FSP) as a simple bench-top tool for comparison of soot emissions from different liquid jet fuels. A sampling assembly is designed for soot collection and particle property analysis. Soot agglomerate size distributions and elemental to total carbon ratios (EC/TC) are measured for three liquid fuels and flame conditions with Reynold's numbers and burner equivalence ratios ranging from 6000 to 9100 and 6.7 to 13.1. Day-to-day variations in the dilution ratio resulted in up to 20% variability in the measured total agglomerate number density and mobility diameters. Geometric mean primary particle and mobility diameter values are below 21 and 113 nm, in excellent agreement with those emitted from jet engines and earlier works using FSP. EC/TC is higher than 0.8 for all flames burning Jet A1, but values as low as 0.55 are measured for soot emitted from SAF burning flames."],"dc:identifier.doi":["10.22215/etd/2023-15367"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41716"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Aerospace engineering"],"dc:title":["Design and Characterization of a Flame Spray Pyrolysis Apparatus to Compare Soot Emissions from Liquid Fuels"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Aerospace"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:56:50Z"}