{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41774"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41774","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"The Lateral and Post-Impact Residual Lateral Strength of Reinforced Concrete Columns","abstract":"Lateral load resistance tests were conducted on 24 concrete columns with various reinforcement configurations and sizes by the author. Of these specimens, 13 were previously subjected to impact loading by Abdallah et al. and were used to evaluate the post-impact performance and lateral load capacity retention. From these tests it was determined that the CFST specimens exhibited both the largest lateral and residual lateral capacities of 37.37 kN and 40.17 kN, respectively. The CFST member had the highest retention of lateral load capacity for both low and high impact energy, retaining 75% and 107% of the capacity of the unimpacted specimen, respectively. Increasing the specimen diameter had no discernible effect on lateral strength retention but reduced the residual deformation especially at high impact energies with the residual deformation being reduced as much as 85% compared to the smaller specimen.","abstract_html":"Lateral load resistance tests were conducted on 24 concrete columns with various reinforcement configurations and sizes by the author. Of these specimens, 13 were previously subjected to impact loading by Abdallah et al. and were used to evaluate the post-impact performance and lateral load capacity retention. From these tests it was determined that the CFST specimens exhibited both the largest lateral and residual lateral capacities of 37.37 kN and 40.17 kN, respectively. The CFST member had the highest retention of lateral load capacity for both low and high impact energy, retaining 75% and 107% of the capacity of the unimpacted specimen, respectively. Increasing the specimen diameter had no discernible effect on lateral strength retention but reduced the residual deformation especially at high impact energies with the residual deformation being reduced as much as 85% compared to the smaller specimen.","abstract_has_math":false,"creators":["George, Mickey Brayden"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Civil","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:15:23Z","subjects":["Civil engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15931"],"render_values":[{"text":"10.22215/etd/2023-15931","href":"https://doi.org/10.22215/etd/2023-15931","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41774","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41774","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41774","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["George, Mickey Brayden"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:25:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:25:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Civil"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Civil engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15931"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41774"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lateral load resistance tests were conducted on 24 concrete columns with various reinforcement configurations and sizes by the author. Of these specimens, 13 were previously subjected to impact loading by Abdallah et al. and were used to evaluate the post-impact performance and lateral load capacity retention. From these tests it was determined that the CFST specimens exhibited both the largest lateral and residual lateral capacities of 37.37 kN and 40.17 kN, respectively. The CFST member had the highest retention of lateral load capacity for both low and high impact energy, retaining 75% and 107% of the capacity of the unimpacted specimen, respectively. Increasing the specimen diameter had no discernible effect on lateral strength retention but reduced the residual deformation especially at high impact energies with the residual deformation being reduced as much as 85% compared to the smaller specimen."]},{"key":"dc:title","label":"Title","values":["The Lateral and Post-Impact Residual Lateral Strength of Reinforced Concrete Columns"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["George, Mickey Brayden"],"dc:date.accessioned":["2025-04-08T20:25:21Z"],"dc:date.available":["2025-04-08T20:25:21Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Lateral load resistance tests were conducted on 24 concrete columns with various reinforcement configurations and sizes by the author. Of these specimens, 13 were previously subjected to impact loading by Abdallah et al. and were used to evaluate the post-impact performance and lateral load capacity retention. From these tests it was determined that the CFST specimens exhibited both the largest lateral and residual lateral capacities of 37.37 kN and 40.17 kN, respectively. The CFST member had the highest retention of lateral load capacity for both low and high impact energy, retaining 75% and 107% of the capacity of the unimpacted specimen, respectively. Increasing the specimen diameter had no discernible effect on lateral strength retention but reduced the residual deformation especially at high impact energies with the residual deformation being reduced as much as 85% compared to the smaller specimen."],"dc:identifier.doi":["10.22215/etd/2023-15931"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41774"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Civil engineering"],"dc:title":["The Lateral and Post-Impact Residual Lateral Strength of Reinforced Concrete Columns"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Civil"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:15:23Z"}