{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41780"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41780","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"A Portable, Rapid Isothermal Nucleic Acid Amplification System with Integrated Microfluidics for Pandemic Surveillance","abstract":"Integration of small-footprint cost-effective isothermal rapid DNA extraction, amplification, and detection systems is crucial to achieving a point-of-care pathogen detection system suitable for resource-limited locations. The herein system measures low-level fluorescent signals in real-time during nucleic acid amplification, while maintaining the desired assay temperature on a low-power, portable footprint. A thermally stable microfluidic device was implemented to mitigate thermocapillary effects and facilitate optical alignment for automated image capture and signal analysis. The system uses Loop-Mediated Isothermal Amplification with primers sensitive to broad strains and lineages of SARS-CoV-2 with viral loads corresponding to cycle thresholds from 16 to 39. Among the 54 samples tested through optimizations, the platform yielded an 84% true positive rate. Preliminary investigations were conducted on developing an electromagnetic extraction process by printing a conductive coil around a microfluidic channel. The extraction module was designed to be integrated with the detection system into a sample-to-results point-of-care system.","abstract_html":"Integration of small-footprint cost-effective isothermal rapid DNA extraction, amplification, and detection systems is crucial to achieving a point-of-care pathogen detection system suitable for resource-limited locations. The herein system measures low-level fluorescent signals in real-time during nucleic acid amplification, while maintaining the desired assay temperature on a low-power, portable footprint. A thermally stable microfluidic device was implemented to mitigate thermocapillary effects and facilitate optical alignment for automated image capture and signal analysis. The system uses Loop-Mediated Isothermal Amplification with primers sensitive to broad strains and lineages of SARS-CoV-2 with viral loads corresponding to cycle thresholds from 16 to 39. Among the 54 samples tested through optimizations, the platform yielded an 84% true positive rate. Preliminary investigations were conducted on developing an electromagnetic extraction process by printing a conductive coil around a microfluidic channel. The extraction module was designed to be integrated with the detection system into a sample-to-results point-of-care system.","abstract_has_math":false,"creators":["Staples, Jake William James"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T06:52:46Z","subjects":["Electrical engineering","Biomedical engineering"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15934"],"render_values":[{"text":"10.22215/etd/2023-15934","href":"https://doi.org/10.22215/etd/2023-15934","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41780","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41780","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41780","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Staples, Jake William James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:25:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:25:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15934"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41780"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Integration of small-footprint cost-effective isothermal rapid DNA extraction, amplification, and detection systems is crucial to achieving a point-of-care pathogen detection system suitable for resource-limited locations. The herein system measures low-level fluorescent signals in real-time during nucleic acid amplification, while maintaining the desired assay temperature on a low-power, portable footprint. A thermally stable microfluidic device was implemented to mitigate thermocapillary effects and facilitate optical alignment for automated image capture and signal analysis. The system uses Loop-Mediated Isothermal Amplification with primers sensitive to broad strains and lineages of SARS-CoV-2 with viral loads corresponding to cycle thresholds from 16 to 39. Among the 54 samples tested through optimizations, the platform yielded an 84% true positive rate. Preliminary investigations were conducted on developing an electromagnetic extraction process by printing a conductive coil around a microfluidic channel. The extraction module was designed to be integrated with the detection system into a sample-to-results point-of-care system."]},{"key":"dc:title","label":"Title","values":["A Portable, Rapid Isothermal Nucleic Acid Amplification System with Integrated Microfluidics for Pandemic Surveillance"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Staples, Jake William James"],"dc:date.accessioned":["2025-04-08T20:25:28Z"],"dc:date.available":["2025-04-08T20:25:28Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Integration of small-footprint cost-effective isothermal rapid DNA extraction, amplification, and detection systems is crucial to achieving a point-of-care pathogen detection system suitable for resource-limited locations. The herein system measures low-level fluorescent signals in real-time during nucleic acid amplification, while maintaining the desired assay temperature on a low-power, portable footprint. A thermally stable microfluidic device was implemented to mitigate thermocapillary effects and facilitate optical alignment for automated image capture and signal analysis. The system uses Loop-Mediated Isothermal Amplification with primers sensitive to broad strains and lineages of SARS-CoV-2 with viral loads corresponding to cycle thresholds from 16 to 39. Among the 54 samples tested through optimizations, the platform yielded an 84% true positive rate. Preliminary investigations were conducted on developing an electromagnetic extraction process by printing a conductive coil around a microfluidic channel. The extraction module was designed to be integrated with the detection system into a sample-to-results point-of-care system."],"dc:identifier.doi":["10.22215/etd/2023-15934"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41780"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Electrical engineering","Biomedical engineering"],"dc:title":["A Portable, Rapid Isothermal Nucleic Acid Amplification System with Integrated Microfluidics for Pandemic Surveillance"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T06:52:46Z"}