{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41814"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41814","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"A Confidence Framework for Heart Rate Estimation in Video Magnification","abstract":"The recent pandemic as well as solutions to support independent living for aging adults lead to a need for in-home health monitoring solutions. Video magnification (VM) is a contactless and remote method that measures heart rate (HR) which is a vital parameter and an indicator of the overall health and well-being of individuals. Body motion, illumination, and skin color can affect VM performance, and this thesis proposes a methodology to understand the confidence in VM heart rate assessments. The thesis proposes spatial methods combining VM assessment from different skin regions in time and frequency domains and temporal methods combining VM assessments from adjacent time windows to improve VM HR estimation and provide confidence assessments. The thesis then proposes the use of machine learning models to assess the overall confidence in the VM assessed HR to indicate whether this HR is likely correct or incorrect.","abstract_html":"The recent pandemic as well as solutions to support independent living for aging adults lead to a need for in-home health monitoring solutions. Video magnification (VM) is a contactless and remote method that measures heart rate (HR) which is a vital parameter and an indicator of the overall health and well-being of individuals. Body motion, illumination, and skin color can affect VM performance, and this thesis proposes a methodology to understand the confidence in VM heart rate assessments. The thesis proposes spatial methods combining VM assessment from different skin regions in time and frequency domains and temporal methods combining VM assessments from adjacent time windows to improve VM HR estimation and provide confidence assessments. The thesis then proposes the use of machine learning models to assess the overall confidence in the VM assessed HR to indicate whether this HR is likely correct or incorrect.","abstract_has_math":false,"creators":["Elhajjar, Diane Geena"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:12:07Z","subjects":["Medical physics"],"languages":["en"],"rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15813"],"render_values":[{"text":"10.22215/etd/2023-15813","href":"https://doi.org/10.22215/etd/2023-15813","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41814","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41814","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41814","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Elhajjar, Diane Geena"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:26:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:26:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Medical physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2023-15813"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41814"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The recent pandemic as well as solutions to support independent living for aging adults lead to a need for in-home health monitoring solutions. Video magnification (VM) is a contactless and remote method that measures heart rate (HR) which is a vital parameter and an indicator of the overall health and well-being of individuals. Body motion, illumination, and skin color can affect VM performance, and this thesis proposes a methodology to understand the confidence in VM heart rate assessments. The thesis proposes spatial methods combining VM assessment from different skin regions in time and frequency domains and temporal methods combining VM assessments from adjacent time windows to improve VM HR estimation and provide confidence assessments. The thesis then proposes the use of machine learning models to assess the overall confidence in the VM assessed HR to indicate whether this HR is likely correct or incorrect."]},{"key":"dc:title","label":"Title","values":["A Confidence Framework for Heart Rate Estimation in Video Magnification"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Elhajjar, Diane Geena"],"dc:date.accessioned":["2025-04-08T20:26:05Z"],"dc:date.available":["2025-04-08T20:26:05Z"],"dc:date.issued":["2023"],"dc:description.abstract":["The recent pandemic as well as solutions to support independent living for aging adults lead to a need for in-home health monitoring solutions. Video magnification (VM) is a contactless and remote method that measures heart rate (HR) which is a vital parameter and an indicator of the overall health and well-being of individuals. Body motion, illumination, and skin color can affect VM performance, and this thesis proposes a methodology to understand the confidence in VM heart rate assessments. The thesis proposes spatial methods combining VM assessment from different skin regions in time and frequency domains and temporal methods combining VM assessments from adjacent time windows to improve VM HR estimation and provide confidence assessments. The thesis then proposes the use of machine learning models to assess the overall confidence in the VM assessed HR to indicate whether this HR is likely correct or incorrect."],"dc:identifier.doi":["10.22215/etd/2023-15813"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41814"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2023 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Medical physics"],"dc:title":["A Confidence Framework for Heart Rate Estimation in Video Magnification"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:12:07Z"}