{"id":{"repo_id":"carleton","oai_identifier":"oai:carleton.scholaris.ca:20.500.14718/41863"},"canonical_url":"https://search.ndltd.org/etd/carleton/oai:carleton.scholaris.ca:20.500.14718/41863","repository":{"repo_id":"carleton","name":"Carleton University","base_url":"https://carleton.scholaris.ca/server/oai/request"},"display":{"title":"Heart Rate Detection using Video Magnification: Impact of Algorithmic Parameters and Noise","abstract":"Screening people for illnesses in public spaces using contactless techniques such as Video Magnification (VM) can be beneficial for both the crowd and the operators. One important vital sign to screen for is heart rate because it is indicative of the overall health of humans. In this thesis, first the impact of varying two input parameters (region of interest (ROI) size and window segment length) on VM is explored. Second, the impact of noise from three different sources (quantization, modern camera systems coupled with software enhancements, and light illumination) is explored. Results show that heart rate can be detected from very small ROIs, but that larger ROIs have higher accuracy. Larger window segment lengths are useful in the presence of motion. VM detects signals with amplitudes equal to one quantization level in 8-bit videos. VM is affected by modern camera systems, and it is more accurate with higher light illuminations.","abstract_html":"Screening people for illnesses in public spaces using contactless techniques such as Video Magnification (VM) can be beneficial for both the crowd and the operators. One important vital sign to screen for is heart rate because it is indicative of the overall health of humans. In this thesis, first the impact of varying two input parameters (region of interest (ROI) size and window segment length) on VM is explored. Second, the impact of noise from three different sources (quantization, modern camera systems coupled with software enhancements, and light illumination) is explored. Results show that heart rate can be detected from very small ROIs, but that larger ROIs have higher accuracy. Larger window segment lengths are useful in the presence of motion. VM detects signals with amplitudes equal to one quantization level in 8-bit videos. VM is affected by modern camera systems, and it is more accurate with higher light illuminations.","abstract_has_math":false,"creators":["Yassin Kassab, Leen"],"institution":"Carleton University","degree_name":"Master of Applied Science (M.App.Sc.)","degree_level":"Master's","degree_discipline":"Engineering, Electrical and Computer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:10:47Z","subjects":["Heart rate monitoring"],"languages":["en"],"rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15000"],"render_values":[{"text":"10.22215/etd/2022-15000","href":"https://doi.org/10.22215/etd/2022-15000","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/20.500.14718/41863","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/20.500.14718/41863","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://carleton.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acarleton.scholaris.ca%3A20.500.14718%2F41863","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yassin Kassab, Leen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-04-08T20:26:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-04-08T20:26:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["Carleton University"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering, Electrical and Computer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science (M.App.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heart rate monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.22215/etd/2022-15000"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/20.500.14718/41863"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Screening people for illnesses in public spaces using contactless techniques such as Video Magnification (VM) can be beneficial for both the crowd and the operators. One important vital sign to screen for is heart rate because it is indicative of the overall health of humans. In this thesis, first the impact of varying two input parameters (region of interest (ROI) size and window segment length) on VM is explored. Second, the impact of noise from three different sources (quantization, modern camera systems coupled with software enhancements, and light illumination) is explored. Results show that heart rate can be detected from very small ROIs, but that larger ROIs have higher accuracy. Larger window segment lengths are useful in the presence of motion. VM detects signals with amplitudes equal to one quantization level in 8-bit videos. VM is affected by modern camera systems, and it is more accurate with higher light illuminations."]},{"key":"dc:title","label":"Title","values":["Heart Rate Detection using Video Magnification: Impact of Algorithmic Parameters and Noise"]},{"key":"local:lac.licence","label":"Local Lac Licence","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:creator":["Yassin Kassab, Leen"],"dc:date.accessioned":["2025-04-08T20:26:56Z"],"dc:date.available":["2025-04-08T20:26:56Z"],"dc:date.issued":["2022"],"dc:description.abstract":["Screening people for illnesses in public spaces using contactless techniques such as Video Magnification (VM) can be beneficial for both the crowd and the operators. One important vital sign to screen for is heart rate because it is indicative of the overall health of humans. In this thesis, first the impact of varying two input parameters (region of interest (ROI) size and window segment length) on VM is explored. Second, the impact of noise from three different sources (quantization, modern camera systems coupled with software enhancements, and light illumination) is explored. Results show that heart rate can be detected from very small ROIs, but that larger ROIs have higher accuracy. Larger window segment lengths are useful in the presence of motion. VM detects signals with amplitudes equal to one quantization level in 8-bit videos. VM is affected by modern camera systems, and it is more accurate with higher light illuminations."],"dc:identifier.doi":["10.22215/etd/2022-15000"],"dc:identifier.uri":["https://hdl.handle.net/20.500.14718/41863"],"dc:language.iso":["en"],"dc:publisher":["Carleton University"],"dc:rights":["Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner."],"dc:subject.lcsh":["Heart rate monitoring"],"dc:title":["Heart Rate Detection using Video Magnification: Impact of Algorithmic Parameters and Noise"],"dc:type":["thesis"],"local:lac.licence":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Engineering, Electrical and Computer"],"thesis:degree_level":["Master's"],"thesis:degree_name":["Master of Applied Science (M.App.Sc.)"]},"updated_at":"2026-11-19T07:10:47Z"}